W3003 12V/24V/220V Microcomputer Digital Display intelligent Temperature Controller Electronic for Burner Fuel Machine Controller

SKU: GP-1428282

$15.75

Voltage 12V / Voltage 24V /

Dispatch:Usually will be shipped in 24 hours
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard

Specifications
Supply voltage:12V/24V/220V
Load power:120/240/1500W
Temperature control range:0-450 °C
Temperature range:0-450 °C
Temperature control accuracy:0.1 °C
Measurement input:k-type thermocouple
Output type:direct output
Output capacity:up to 10A
Mounting aperture:73mm
Aperture:4mm
Size:60*45*31mm
Introduction
Setting parameter table
Code:Description:Setting range:Factory settings
P0:Starting temperature:0-450→:00
P1:Stop temperature:0-450→:00
P2:Temperature correction:-10-10→:0
P3:Delayed start:0-10 min:0
– P0 sets the starting temperature
Press the setup button to enter the internal menu. The default display is T0. Press the setup button again to set the desired startup temperature via the up and down buttons.
– P1 sets the stop temperature
b Set the button to enter the internal menu, the digital display is P0, switch to P1 through the up and down buttons, press the setting button again, and set the required stop temperature through the up and down buttons.
– P2 set temperature correction
In the same way, enter the internal menu, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by the up and down buttons. In the setting, if the detected temperature value is 0.5 °C larger than the actual temperature value, then the calibration temperature to be set is -0.5 °C. If the inspection temperature value is 1 °C smaller than the actual temperature value, the calibration temperature to be set is 1 °C. Temperature + – Correction temperature = actual temperature.
– P3 sets delayed start
In the same way, enter the internal menu, switch to P3 by the up and down keys, press the setting button again, and set the required delay time by the up and down buttons (the unit is minute > delay start is generally used for compressor refrigeration, if needed for refrigerator freezer, This value needs to be set. The value of the compressor back pressure is set to 3-6 minutes. If you are not using it to control the compressor or do not need the delay function, skip this item.
Heating mode setting method
Setting method:starting temperature
Setting method
Press the SET button to enter the internal menu, set the startup temperature by setting the P0 value, and set the stop temperature by setting the P1 value.
Use Cases
Control the water heater, heat it to 50 °C to stop, and the temperature will fall back to 40 °C to start heating again. How to set it
Step 1:Determine the working mode as heating mode, starting temperature
Step 2:Press the SET button to enter the internal menu, select P0 and press the SET button to set the P0 value to 40 °C.
Step 3:Press the SET button to enter the internal menu, select P1 and press the SET button to set the P1 value to 50 °C.
Cooling mode setting mode
Setting method:Start temperature > stop temperature (program automatically determines the working mode is cooling mode)
The setting method is as above.
Note
When setting the heating mode, if you accidentally set the set temperature value upside down, the output indicator will not light, the load will not work. If the above situation occurs after the setting is completed, you can check whether the set temperature value is reversed. .
Package Included
1 x Digital Display Intelligent Temperature Controller

Weight0.066 kg

Reviews

There are no reviews yet.

Be the first to review “W3003 12V/24V/220V Microcomputer Digital Display intelligent Temperature Controller Electronic for Burner Fuel Machine Controller”

Your email address will not be published. Required fields are marked *

SKU: GP-1428282 Category:

Customers Also Viewed

Cart

Your Cart is Empty

Back To Shop