5pcs XH-W1302 High Precision Digital Temperature Controller Special for 12V input 12V Output Semiconductor Refrigeration Chip
$77.46
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
High-speed flash RAM processing chip
Power-off setting automatic memory
Control accuracy 0.1 degrees Celsius
Button buzzer (can be turned off)
High temperature buzzer alarm (0-110 degrees free setting)
Set the hysteresis of 0.5, control the decimal (0.5-15.0)
Technical parameter
Temperature control range:-50~110°C
Resolution:-9.9~99.9 when 0.1 °C Other temperature range 1 °C
Temperature measurement accuracy:0.1 °C
Control accuracy:0.1 °C
Hysteresis accuracy:0.1 °C
Refresh rate:0.5 S
Input power:DC/AC 12V
Measurement input:NTC (10K 0.5%) waterproof sensor
Output:1 relay output, capacity = 10A
Environmental requirements:-10~60°C Humidity 20%-85%
Specification size:78*51mm (mounting hole M3. diagonal 75mm)
Power consumption of the whole machine:quiescent current:≤35MA Pull-in current:≤65MA
Package includes
5 x XH-W1302 High Precision Digital Temperature Controller
Instructions
Connect the power supply and equipment to supply power to the controller. At this time, it is displayed as measuring temperature. Press SET once, the display temperature will flash, press +- to set the desired temperature (press +- to quickly raise and lower) After finishing, press SET to confirm the return. At this time, the controller automatically performs relay on/off according to the setting! The output of the thermostat is a 10A relay, which satisfies various high-power loads, and connects the control circuit to supply power to the thermostat. At this time, the display shows the ambient temperature.
Fourth, the indicator light, digital tube and buzzer status description
Indicator light:Blinking indicates cooling or heating start delay, always on indicates that the relay is closed
Digital tube:Display LL is the sensor open circuit, please follow the instructions to connect the sensor; display HH is out of the measurement range, the thermostat will force the relay to be disconnected; display — for high temperature alarm
Buzzer:When the digital tube displays LL, HH or —, the buzzer emits a di-di-di -beep
Parameter function description
Code:Code description:Set range:Factory setting
P0:Cooling/heating:C/H:C
P1:Backlash setting:0.5-15:2
P2:Maximum setting limit:110:110
P3:Minimum setting lower limit:-50:-50
P4:Temperature correction:-7~7°C:0
P5:Delayed start time:0-10 min:0
P6:Buzzer switch:ON/OFF:ON
P7:High temperature alarm:0-110°:OFF
P8:Reset:ON/OFF:OFF
Press and hold SET for 5 seconds to enter the main menu settings, press +- to switch P0…P8 long press SET or 10 seconds without button action controller automatically confirm return
P0:cooling and heating mode
Press and hold SET for 5 seconds to display P0, press SET once to set the working mode, press +- to switch [H is heating mode] [C is cooling mode] Press SET once to return, long press SET or 10 seconds without button action controller automatically confirm carry out
In the cooling mode:when the temperature measurement value ≥ temperature set point, the refrigeration relay is closed, the refrigerator starts; when the temperature measurement value ≤ temperature set point – the return difference, the refrigeration relay is disconnected, the refrigerator is closed
In the heating mode:when the temperature measurement value ≤ temperature set point, the heating relay pulls in and the heater starts; when the temperature measurement value ≥ temperature set point + hysteresis, the heating relay is turned off and the heater is turned off.
P1:Difference setting
Press and hold SET for 5 seconds to display P0, press +- to switch to P1, press SET once to return the difference, press +- to set the difference to 0.5-15, press SET once when finished, long press SET or 10 seconds without button Motion controller automatically confirms completion
In the cooling mode:when the temperature measurement value ≥ the set value, the relay is closed, the refrigerator starts; when the temperature measurement value ≤ the set value – the difference value, the relay is turned off and the refrigerator is turned off.
For example, the environment is 30 °C, the set value is 25 °C, and the hysteresis is set to 2 °C. After the power is turned on, the relay closes the refrigerator to start. When the cooling reaches 23 °C, the relay turns off the refrigerator and the refrigerator is turned off. The opening temperature starts to rise. When it rises to the set value of 25 °C, the relay closes the refrigerator to start again, so the repeated cycle control temperature is not higher than 25 °C.
In the heating mode:when the temperature measurement value ≤ the set value, the relay is closed, the heater is started; when the temperature measurement value ≥ the set value + the return value, the relay is turned off and the heater is turned off.
For example, if the environment is 10 °C, the set value is 25 °C, and the hysteresis is set to 2 °C. After the power is turned on, the relay closes the heater to start. When it is heated to 27 °C, the relay turns off the heater, and the heater is turned off. The opening temperature begins to decrease. When it drops to the set value of 25 °C, the relay closes the heater again, so the repeated cycle control temperature is not lower than 25 °C.
P2 maximum temperature setting upper limit
In order to avoid the danger of setting the temperature too high due to the misoperation of others, the temperature controller has the highest setting upper limit function, which limits the setting range of the highest temperature setting point controlled by the thermostat.
Press and hold SET for 5 seconds to display P0, press +- to switch to P2, press SET once to set the upper limit, press +- to set the highest settable temperature, the maximum value is 110, press SET once after completion, press SET or 10 Second no button action controller automatically confirms completion
For example:set to 60 temperature set point can only be set to 60 ° C. If the temperature set point is to be expanded, the upper limit set value needs to be adjusted first.
P3 lowest temperature setting lower limit
In order to avoid the ice blockage caused by the misoperation of others, the temperature controller has the lowest setting upper and lower limit functions, which limits the setting range of the lowest temperature set point controlled by the thermostat.
Press and hold SET for 5 seconds to display P0, press +- to switch to P3, press SET once to set the minimum lower limit, press +- to set the lowest settable temperature, the lowest value is -50, press SET once after completion, press SET or 10 seconds without button action controller automatically confirms completion
For example:set to 2 temperature set point can only be set to 2 °C minimum. If the temperature set point is to be expanded at a lower temperature range, you need to adjust the lower limit set value first.
P4 temperature correction
When the measured temperature is deviated from the standard temperature or due to special needs of the user’s hardware, this function can be used for correction. The corrected temperature = temperature before correction + correction value The valid range is -7.0~7.0
Press and hold SET for 5 seconds to display P0, press +- to switch to P4, press SET once to correct, press +- to set the correction value, press SET once after completion, long press SET or 10 seconds without button action controller automatically confirms completion
For example, the normal display is 25 degrees; when the temperature is corrected to 0, it displays 25 degrees; when the temperature is corrected to 1.5, it shows 26.5 degrees; when the temperature is corrected to -1.5, it shows 23.5;
P5 Delay start time Unit:minute
When the refrigerator or heater is working with a delay, the delay function can be turned on to protect the life of the device.
Press and hold SET for 5 seconds to display P0, press +- to switch to P5, press SET once to set the delay start time unit is minute, press +- to set 0-10 minutes, press SET once after completion, press SET for 10 seconds No button action controller automatically confirms completion
In the cooling mode:the first time the power is turned on, if the current temperature ≥ the set value, the refrigerator will not start the cooling immediately, and it needs to run after the set delay time.
In the heating mode:the first time the power is turned on, if the current temperature ≤ the set value, the heater will not start the heating immediately, and it needs to run after the set delay time.
The chiller starts immediately when the downtime between the two starts of the chiller or heater is greater than the set value of the delay start time;
When the stop interval between the two starts of the refrigerator or heater is less than the set value of the delay start time, the device can start after restarting the set delay time of the set after the run. The delay time is calculated from the moment of shutdown.
For example, the setting delay is 5 minutes in the cooling state, the cooling device starts to delay after the power is turned on, and the refrigerator is turned on after 5 minutes. When the required temperature is reached, the refrigerator stops, and the timing starts, when the next cooling start timing is completed. Work, unfinished time to wait for the end of the time to work, the LED indicator flashes during the delay
When the delay start is set to 0, it is equal to the off delay function.
P6 button tone switch
Press and hold SET for 5 seconds to display P0, press +- to switch to P6, press SET once to set whether to enable button sound, press +- to set on/off, press SET once after completion, long press SET or 10 seconds without button action control Automatic confirmation is completed
When the buzzer switch is set to on/off, the button will sound when the button is activated, and the buzzer will be turned off when the button is set to off.
P7 high temperature alarm
Press and hold SET for 5 seconds to display P0, press +- to switch to P7, press SET once to display on/off (set to off to turn off secondary function). Set to on and press SET once to set high temperature alarm temperature point, press +- to set 0 ~110, press SET once after completion, long press SET or 10 seconds without button action controller automatically confirms completion
The high temperature alarm setting range is 0-110 or off for the secondary function. After reaching the high temperature alarm, the buzzer will make a rapid drip sound and force the relay to be disconnected.
For example, we need to warm a liquid or space to 40 degrees, set 80 degrees as a dangerous temperature, and start the high temperature alarm relay to disconnect the buzzer when the temperature is higher than 80 degrees due to external irresistible factors. Alarm, promptly remind the staff to take corresponding measures to recover the loss! The alarm temperature can be set according to actual needs. If you do not want this function, you can set the temperature to off. Note that when the normal temperature is restored, the high temperature alarm thermostat is automatically released.
P8 Factory reset
Due to some human reasons, the internal setting of the thermostat is confusing. It takes a lot of time to set the item. In this case, you can use this function to restore the factory settings. The specific method is
Press and hold SET for 5 seconds to display P0, press +- to switch to P8, press SET once to set to on or off, on to restore factory settings, off to not perform any action, press SET to return after completion, long press SET or 10 seconds The clock no button action controller automatically restores the factory settings parameters as shown in the table below.
Weight | 0.225 kg |
---|
Customers Also Viewed
500pcs 0805 (2012) SMD White LED Chip Surface Mount SMT Beads Ultra Bright Light Emitting Diode LED Lamp Electronics Components
$26.89Electronic Accessories & SuppliesAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.DescriptionQuantity:500 pieces Size:2.0 x 1.2 (mm) / 0.08 x 0.05 (inch)Emitting Color:White (6000K-9000K)Luminous Intensity:180-210mcdViewing Angle:120 DegreeForward Voltage / Current:3V-3.2V | 20mAPolarity:Refer to the Arrow on the Reverse SidePackage included500 x 0805 (2012) …
5pcs AC 100-240V to DC 12V 5A 60W Switching Power Supply Module Driver Adapter LED Strip Light
$52.97Power Supply ModuleAdd to cartFeatures1. Good anti-interference performance and high reliability.2. Low operating temperature and long service life.3. Wide input voltage range, (100-240V) in line with global usage standards.4. Good insulation performance and high electric strength.5. Full load high temperature burning machine, 100% aging test.SpecificationsModel:HS-60-12DC output voltage:12VOutput voltage tolerance:±1%Rated output current:5AOutput current range:0 – 5ARipple and noise:100mVp-pLine stability:±0.5%Load stability:±0.5%DC …
4Pcs 5mm Reusable Clear Bent Glass Drinking Straws Water Juice Straws with Cleaning Brush
$22.26Bottles & JarsAdd to cartSpecificationColor:ClearMaterial:High Borosilicate GlassTube Mouth Shape:RoundTemperature Resistance:-20~450℃Total Length:21.5cm / 8.46inchInner Diameter:0.5cmFeatures– Non-toxic environmentally friendly green borosilicate heat-resistant material, safe to use, not stain, will not fade.– Widely used, can drink water, milk, juice, coffee, coke, soda, etc.– Could put it into the microwave for sterilization.Package Included4 x Glass Drinking Straws1 x Cleaning Brush
5Pcs Car Window Sun Visor Screen Car Side Rear Window Screen Sunshade Shield Curtain
$19.83Mesh & Wire ClothAdd to cartDescriptions5Pcs Car Window Sun Visor Screen Car Side Rear Window Screen Sunshade Shield CurtainSpecificationsSizeRear Sun Visor:50 * 100 CmThe Front Side Of The Sun Visor:36 * 44 CmThe Back Side Of The Sun Visor:36 * 44 CmMaterial:3D Photocatalyst MeshWeight:Approx.60 gFeatures– Convenient to use and take down with two suckers.– Can reflect 90% direct sunlight and …
5Pcs Car Window Sun Visor Screen Car Side Rear Window Screen Sunshade Shield CurtainRead More
5Pcs Micro USB TP4056 Charge And Discharge Protection Module Over Current Over Voltage Protection
$9.32Battery Protection ModuleAdd to cartCharacteristicOn-board TP4056 lithium battery charging management chipOn-board micro USB head, can be directly connected with most of the smart phone charger as the input side to the lithium battery chargingReserved IN+ and IN- input port, convenient user DIYOn-board charging status indicatorSupport charge discharge over current protectionChip with constant current and constant pressure, full automatic stopSupports …
Keyes Brick TEMT6000 Light Sensor(Pad hole) Analog Signal Module with Pin Header Version
$6.10Sensor & Detector ModuleAdd to cartDescriptionThis is a commonly used TEMT6000 light sensor which mainly uses TEMT6000X01 components. The component is a highly sensitive visible light sensitive (NPN) transistor. The sensor can magnify the change of the tiny light rays captured about 100 times, and is easily recognized by the microcontroller for AD conversion. Its response to visible light illumination …
Keyes Brick TEMT6000 Light Sensor(Pad hole) Analog Signal Module with Pin Header VersionRead More
100W18V Foldable Portable Monocrystalline Solar Panel with 5V USB Port
$301.75Smart Robot & Solar PanelAdd to cartFeatures– The outermost layer of the product is made of thick and breathable nylon bag. It`s easy to carry and portable coz it`s folable and has a handle, which is suitable for camping, hiking, hiking, and can be used as a backup power source for mobile phones and car batteries.– It`s equipped a USB&DC junction …
100W18V Foldable Portable Monocrystalline Solar Panel with 5V USB PortRead More
GY-213V-HDC1080 High Accuracy Digital Humidity Sensor with Temperature Sensor
$15.30Sensor & Detector ModuleAdd to cartDescriptionThe HDC1080 is a digital humidity sensor with integrated temperature sensor that provides excellent measurement accuracy at very low power. The HDC1080 operates over a wide supply range, and is a low cost, low power alternative to competitive solutions in a wide range of common applications. The humidity and temperature sensors are factory calibrated.FeaturesRelative Humidity …
GY-213V-HDC1080 High Accuracy Digital Humidity Sensor with Temperature SensorRead More
Reviews
There are no reviews yet.