3Pcs J03 LED Digital Time Delay Relay DC 6-30V on off Trigger Delay Timming Timer Switch Micro USB Power Supply 5V 12V
$32.79
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. Wide voltage power supply (6 ~ 30V), supports microUSB 5.0V power supply, easy to use;
2. The interface is clear and simple, powerful, easy to understand, meet almost all your needs;
3. The emergency stop function (“STOP’key);With reverse polarity protection, reverse polarity will not burn the product.
4. Increase the sleep mode, if this mode is enabled, without any operation within 5 minutes, then automatically turn off the monitor, any key wake-up;
5. You can set a different OP, CL, LOP parameters, which are independent of each other, and are automatically saved;
6. After the module is powered down, all parameter settings are not lost.
Product parameters
1:Operating voltage:6–30V, support microUSB 5.0V power supply
2:Trigger Source:Active-high (3.0V-24V), have optocoupler isolation, can improve the system’s anti-jamming capability (customers can also shorting common ground).
3:Output capability:You can control the DC 30VDC 5A or 220VAC 5A device.
4:Quiescent Current:20mA; Operating Current:50mA
5:Life:more than 10 million times; Working temperature:-40→-85 →; Size:6.2*3.8*1.7cm.
6:With optocoupler isolation, enhanced anti-jamming capability, industrial grade board.
Special Note:The relay outputs are passive contact, just a switch.
Operating mode
P1:trigger signal, the relay is on ‘OP’ time, and then disconnect; in the ‘OP’ time, as follows
P1.1:signal is triggered again, invalid
P1.2:signal is triggered again, the clock is reset
P1.3:Signal trigger again, relay off, stop the clock;
P-2:trigger signal, the relay off ‘CL’ of time, the relay on ‘OP’ time, and then disconnect relay;
P3.1:trigger signal, the relay is turned on after the ‘OP’ time, the relay off ‘CL’ time, then the operation cycle, if the trigger signal period, the relay off, stop the clock; the number of cycles ( ‘LOP ‘) can be set.
P3.2:without triggering signal, the relay is on ‘OP’ time, the relay off ‘CL’ time, and has been cycling; frequency ( ‘LOP’) cycle can be set;
P-4:signal holding function. If there is a trigger signal timing is cleared, the relay remains on; when the signal disappears, after the timing ‘OP’ time, the relay is; if another signal during timing, timing is cleared.
Timing range
0.1 seconds (min) to 999 minutes (max) continuously adjustable
How to choose the time range
After setting the mode selection screen parameter value by a short press ‘STOP’ button to select the time range;
XXX. decimal point in the unit place, time range:1 second to 999 seconds.
XX. X decimal point in decade place, Timing range:0.1 seconds to 99.9 seconds
X. X. X. decimal full brightness, Timing range:1 minute to 999 minutes.
For example, you want to set ‘OP’ is 3.2 seconds, then move the decimal point to decade place, the digital display 03.2
Parameter description:’OP’ – conduction time, ‘CL’ – off time, ‘LOP’ – the number of cycles (1-999 times, ‘—‘ represents infinite loop).
These parameters are independent of each other, but is shared by each mode. For example, in P1.1 mode, set the on-time ‘OP’ is 5 seconds, if you switch to P1.2 mode, it’s ‘OP’ will be 5 seconds too.
In the main interface (display 000), short press ‘SET’ button will display ‘OP’ ( ‘CL’, ‘LOP’) and the corresponding time XXX;
Some parameters only mode ‘OP’ (such as the mode P1.1, P1.2, P1.3), short press the ‘SET’ key to display only the “OP” and the corresponding time;
Some models have parameters ‘OP’,’CL’, ‘LOP’ (such as the mode P3.1, P3.2), short press ‘SET’ button will display ‘OP’ and the corresponding time, “CL” and the corresponding time, “LOP” and the corresponding number of times;
In the main interface by short press ‘SET’ key to see information about the parameters of the current mode, very convenient!
How to set parameters
1. First, read the instructions to determine the required operating mode.
2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press ‘SET’ button for 2 seconds after release to enter mode selection interface; a short time by pressing ‘UP’, ‘DOWN’ key to select the mode (P1.1 ~ P-4).
3. Select the mode (such as P3.2), short press the ‘SET’ button, then the parameter to be set flashes ( ‘OP’on-time, ‘CL’ off time, ‘LOP’ cycles ( ‘—‘ represents infinite loop)), by ‘UP’, ‘DOWN’ keys to adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease one unit); then short press the ‘STOP’ key to select the decimal point position, select the time range (0.1 seconds to 999 minutes); short press the ‘SET’ button to set the next parameters of the current mode of procedure is as above.
4. After the parameters are set, long press ‘SET’ button for 2 seconds then release, the name of the current mode will flash once, and then return to the main screen, set the parameters of success!
The main interface:In the relay does not work status display ‘000’ (no decimal point), with a decimal point under relay state.
Mode selection screen:Long press the ‘SET’ key to enter, after setting is completed, long press the ‘SET’ key to exit back to the main screen.
‘STOP’ button extensions
Relays enable mode
1. ON:Relay allows conduction in the ‘OP’ on-time;
2. OFF:relay prohibit conduction is always closed;
In the main interface, short press the ‘STOP’ button to switch between ON and OFF, the current in which the state will flash, and then return to the main screen. (This feature is an emergency stop function, click off the relay)
Sleep mode
1. ‘C-P’ Sleep mode:five minutes without any operation, the digital display automatically turns off, the program running as usual;
2. ‘O-d’ normal mode:digital display always open;
Press the ‘STOP’ button for two seconds and then release to switch ‘C-P’ and ‘O-d’ state, in which the current state of flashes and then return to the main screen.
Package Included
3 x DC 1 Channel Time Delay Relay Module
3 x Shell Case
Weight | 0.222 kg |
---|
Customers Also Viewed
10pcs MAX9814 High Performance Microphone AGC Amplifier Module CMA-4544PF-W
$90.79Amplifier BoardAdd to cartSpecifications– Supply Voltage:2.7v-5.5v @ 3mA current– Output:2Vpp on 1.25V bias– Frequency Response:20Hz – 20KHz– Programmable Attack and Release Ratio– Automatic gain, selectable max from 40dB, 50dB or 60dB– Low Input-Referred Noise Density of 30nV/– Low THD:0.04% (typ)– Low Power Shutdown Mode– Built-in 2V low-noise microphone bias– -40°C ~ +85°C extended temperature rangePackage included10 x Microphone …
10pcs MAX9814 High Performance Microphone AGC Amplifier Module CMA-4544PF-WRead More
T-AMP 2 x 15W TA2024 Digital Audio Amplifier Board Mini AMP
$19.04Amplifier BoardAdd to cartFeature1. The power to more than 12V current 3A2. The speaker is best to use an impedance of 4 ohms, some of the high sensitivity3. For some signal level is relatively low tone, to add the preamplifier to play the effect4. Note the positive and negative can not be reversed, use the power supplyElectrical CharacteristicsIts …
T-AMP 2 x 15W TA2024 Digital Audio Amplifier Board Mini AMPRead More
Mega 2560 R3 ATmega2560-16AU Control Module without USB Cable
$44.54Motherboard & Development BoardAdd to cartDescriptionThis is compatible R3 Mega2560 ATmega2560-16AU control board without USB cableMega is an ATmega2560 as core microcontroller development board itself has 54 groups digital I / O input / output terminal (14 groups do PWM outputs), 16 sets of simulation than the input side, group 4 UARTs (hardware serial ports), using the 16 MHz crystal …
Mega 2560 R3 ATmega2560-16AU Control Module without USB CableRead More
20W 420*380*3mm Folding PET Monocrystalline Silicon Solar Panel with Cable Dual USB
$93.62Smart Robot & Solar PanelAdd to cartSpecificationsMaximum Power(Pmax):20WOpen Circuit Voltage(Voc):18VMaximum Power Voltage(Vmp):12vMaximum Power Current(Imp):1.1AMaximum System Voltage(Imp):1000vOutput:USB 5V & DC 18VQuantity of cell:36Cell Effcience %:20%Output Tolerance:±10%Size:425*380*3mmStandard Test Conditions:Irradiance 1000w/m2Temoerature 25.C,AM=1.5Package Included1 x Solar panel with cable
5pcs 8Channel DC 5V RS485 Modbus RTU Control Module UART Relay Switch Board PLC
$45.10Relay ModuleAdd to cartDescriptions– Operating Voltage:DC 5V(5V Version)– Operating Current:10-15MA– inchopeninch inchcloseinch inchMomentaryinch inchSelf-lockinginch inchInterlockinch inchDelayinch 6 Commands– Two instruction-control mode:AT command and MODBUS command– Under the AT command ,the maximum delay is 9999 seconds– Under the MODBUS command ,the maximum delay is 255 seconds– AT commands can be made serial HyperTerminal (serial assistant) Enter;– MODBUS commands can …
5pcs 8Channel DC 5V RS485 Modbus RTU Control Module UART Relay Switch Board PLCRead More
LT1083cp 7A AC 35V Rectifier Filter Power Supply Board DIY Home theater Sound Amplifier Voltage Regulator
$24.04Power Supply ModuleAdd to cartDescriptionLT1083CP feature description (emphasis):It is a linear step-down block. Although the voltage adjustment can be adjusted from 2.5V to 37V, it is recommended that the working differential pressure is within 10V, because the power consumption is proportional to the differential pressure, the greater the differential pressure, the more heat The larger the output current, the …