DC 24V Multifunctional Relay Module with LED Display Delay /Self Lock / Cycle / Timing
$13.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. New upgraded version with up to 20 functions preset to meet more application needs;
2. Optimize the software and hardware design, enhance the anti-interference ability of the module, and the system is more stable and reliable;
3. With power supply anti-reverse function, it will not damage the module due to wrong power supply;
4. The timing can be adjusted between 0.1 seconds and 270 hours;
5. All setting parameters can be saved, and the setting contents will not be lost when power is off.
Electrical Parameter
Working voltage:DC 24V
Working current:05V module is less than 90mA (less than 15mA when the relay is not operating, the display is less than 3mA)
Working temperature:-30 ° C – 70 ° C (limit range -40 ° C – 80 ° C)
Relay normally open port maximum load capacity:DC 0-30V/10A, AC 0-250V/10A
Relay normally closed port maximum load capacity:DC 0-28V/10A, AC 0-125V/10A
Dimensions:66mm x 41mm x 20mm (length x width x height)
Module Interface
Module voltage / signal input:3-wire interface, all interfaces have terminal blocks for user convenience
1, DC+:DC power supply positive
2, DC-:DC power supply negative
3, X1:input signal detection interface
Relay load output:3-wire interface, all terminals have terminal blocks
1, NO:relay normally open interface, the relay is suspended before the suction, after the suction is shorted with COM
2, COM:relay common interface
3, NC:relay normally closed interface, shorted to COM before the relay is sucked, suspended after suction
Module Function
Users can choose the required functions and parameters by simple operation. All parameters can be saved after power-off. The time parameter setting can be adjusted by 0.1 second minimum, and the precision is better than 0.01 second.
For example, if the user selects the function 16, the system will save the user settings, and the function 16 will be automatically run each time the phone is turned on until the user changes the settings again.
Function 1:Power-on delay pull-in:After the delay of T1 from the start of power-on, the relay is closed, T1 is adjustable between 0.1 seconds and 270 hours, and a high-level pulse signal is given to the X1 interface at any time. Reset and resume running;
Function 2:Power-on delay off:When the power is on, the relay is closed. After the T1 time is closed, the relay is disconnected. T1 is adjustable between 0.1 seconds and 270 hours. A high-level pulse signal is given to the X1 interface at any time. , this function resets and restarts;
Function 3:Timing pull-in and then disconnect:the relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 4:Timing disconnection and re-sucking:the relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 5:Infinite loop mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the above state is repeated; T1 and T2 are between 0.1 second and 270 hours. Adjustable between each time, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 6:Infinite loop mode 2:The relay immediately picks up when power is on, the relay turns off after the pull-in time T1 arrives; the relay picks up after the break time T2 arrives, and then repeats the above state, T1 and T2 are in 0.1 second-270 Adjustable between hours, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts operation;
Function 7:Limited cycle mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the NX times are repeated, T1 and T2 are at 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 8:Limited cycle mode 2:The relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and then the NX times are repeated, T1 and T2 are in 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 9:Self-locking relay mode:A high-level pulse signal is sent to the relay X1 interface, the relay is pulled in, and a high-level pulse signal relay is turned off.
Function 10:Level trigger relay mode (including delay off function):When the power is turned on, the relay is disconnected, and a high level signal is sent to the X1 interface. The relay immediately pulls in. After the X1 port signal disappears, the relay still pulls in. After the pull-in time T1 arrives, the relay is turned off, and T1 is adjustable between 0 seconds and 270 hours.
Note:In this function, if T1 is set to 0 seconds, it will become:X1 port has a high level signal relay to pull in, and if there is no signal, it will be disconnected immediately.
Function 11:Timing pull-up after triggering:the relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface, delaying the T1 time relay to pull in, T1 is adjustable between 0.1 seconds and 270 hours, repeating to the X1 interface a high-level pulse signal, repeating the above functions more than once;
Function 12:After the trigger, the timing is disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. The relay is closed, and the T1 time relay is disconnected. The T1 is adjustable between 0.1 seconds and 270 hours. Repeat a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 13:After the trigger, the timing is closed and then disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, T1 And T2 can be adjusted between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions;
Function 14:After the trigger, the timing is disconnected and re-closed:the relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the disconnection time T2 arrives. Pull-in, T1 and T2 are adjustable between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 15:Infinite loop mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected and then repeated. The above actions, T1 and T2 are adjustable between 0.1 second and 270 hours, and a high-level pulse signal is repeatedly given to the X1 interface, and the above functions can be restarted;
Function 16:Infinite loop mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives. Then repeat the above actions, delay T1 and T2 to be adjustable between 0.1 seconds and 270 hours, repeat a high-level pulse signal to the X1 interface, and restart the above functions;
Function 17:Limited cycle timing mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, and then the relay is turned off. Repeat NX times or more, T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, and the cycle number NX is adjustable between 1-9999 times. Repeating a high-level pulse signal to the X1 interface can restart the above functions;
Function 18:Limited cycle timing mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is immediately pulled in, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the break time T2 arrives. Pull in, then repeat NX times or more, at this time T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, the number of cycles NX is adjustable between 1-9999 times, repeating a high-level pulse signal to the X1 interface. , you can restart the above functions;
Function 19:Conditional cycle mode 1:The relay is disconnected at power-on, giving a high-level signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, as long as the X1 port is high. Does not disappear, the module will repeat the above action, T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Function 20:Conditional loop mode 2:The relay is disconnected at power-on, a high level signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives, as long as X1 The high level of the port does not disappear, the module will repeat the above action, the extension T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Package Included
1 x Multifunctional Relay Module
Weight | 0.027 kg |
---|
Customers Also Viewed
M5Stack Ultra-Wideband UWB UnM5Stack Ultra-Wideband UWB Unit indoor Positioning Module DW1000 Low Power Consumption for indoor Wireless Tracking Rangeit indoor Positioning Module DW1000 Low Power Consumption for indoor Wireless Tracking Range
$87.06Test & Measuring ModuleAdd to cartDescriptionUWB is a Unit which integrates the UWB(Ultra Wide Band) communication protocol which uses nanosecond pulses to locate objects and define position and orientation. The design uses the Ai-ThinkerBU01 Transceiver module which is based on Decawave’s DW1000 design. The internal STM32 chip with its integrated ranging algorithm,is capable of 10cm positioning accuracy and also supports …
3 in 1 LED Ultrasonic Anti Barking Pet Dog Train Repeller Control Trainer Device
$36.44Solar CollectorsAdd to cartLED Ultrasonic Dog Repeller Handheld Dog Trainer Device 3 in 1 Anti-barking Stop Bark Dog Deterrent Training ToolsFeaturesUltrasonic design-Adopts ultrasonic technology, make the dogs be quite and can effectively train your dogs to be obedient and stop some unwanted behaviors, protect you from being attacked by unfriend dogs. Multi-function deviceThe dog repeller have 3 functions, …
3 in 1 LED Ultrasonic Anti Barking Pet Dog Train Repeller Control Trainer DeviceRead More
3pcs DC 3.7-7.4V 4A 800-1000KV High Voltage Pulse Generator Super Arc Pulse Ignition Coil Module
$32.59Electronic Accessories & SuppliesAdd to cartDescriptionInput parameters:3.7-7.4V/4A input, cable length:about 10 cm (red + green -)Output parameter:800-1000KV / 0.5A, cabl length:about 16 cmHigh voltage polarization discharge distance:1.5-2cm (don’t exceed)Size:3.4 x 2.3 x 1.7cmAbout input power:can use 3.7V lithium battery input (such as 18650 battery), 4V or 6V lead acid battery and so on. The input voltage current affects the output …
Semiconductor Chilling Plate Cooling fan Kit TEC1-12706 thermoelectric Peltier Cooler Refrigeration Cooling System
$37.17Module KitsAdd to cartDescriptionAdopt TEC1-12706 semiconductor chilling plate, good quality for use.Complete sealed structure, isolating the moisture in the air.Higher reliability than others.Include TEC1-12706 semiconductor cooler and other accessories, easy to install.Great DIY kit for electronic enthusiasts in semiconductor cooling applications.FeatureSemiconductor Chilling Plate:TEC1-12706Size:40 * 40 * 3.75mmInternal Resistance:2.1~2.4Max. Temperature Difference:67C AboveRated Voltage:12V(Vmax. 15V, Starting Current 5.8A)Working Current:Imax.=4~4.6A(Rated 12V)Refrigeration …
Universal 40-Pin ZIF DIP IC Test Board Socket ZIF IC Socket for DIP IC MCU
$16.19SwitchesAdd to cartFeatureThis is a universal ZIF IC test socket.Great pin contact with a leverIt’s suitable for IC with 40 pinsEasy to remove and to program ICsSpecificationColor:greenMounting Type:Through holePitch:Approx. 0.1inchinch inches (2.54mm)Pin Number:40Type:DIP, ZIFSize(L x W x H):Approx. 65mm x 2.2mm x 1.1mm(L x W x H not include the pins and lever)Package Included1 x IC socket
AUDEW Premium Tire Pressure Gauge 0-100 PSI Heavy Duty & Accurate Air Pressure Tire Gauge for Car SUV Truck Motorcycle Bicycle
$28.34Switch AccessoriesAdd to cartSPECIFICATION-Applicable type:car, truck, motorcycle, bike, etc-Operating Temp:- 20 ℃ ~ + 40 ℃-Range:0-100 psi-Unit of measurement:PSI, BAR-Resolution:0.05 kg/cm-Accuracy:+/-1%+0.5psi(relative humidity Temperature 25 ℃)FEATURES1.More than a tire pressure gauge, also can deflate overinflated tires with a built-in air bleeder valve.2.High accuracy and easy to read with 2 units of measurement.3.Made with premium heavy duty matel materials, sturdy …
Reviews
There are no reviews yet.