3pcs 24V XH-W1818 High Precision Microcomputer Temperature Controller Circular Digital Display Embedded thermostat
$42.69
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Feature
Product Name:High precision microcomputer temperature controller
Product model:XH-W1818
Temperature range:-50~110°C
Resolution:0.1 ° C
Temperature control range:-50~110°C
Temperature control accuracy:1 ° C
Temperature probe:NTC10K (B3950) L=1M
Supply voltage:DC24V
Applicable environment:-25~55°C Humidity 50%-85%
Output type:10A relay output
Appearance size:diameter 80mm
Opening size:diameter 61mm/3mm
How to use
1. Connect the power supply and load according to the instructions. Please do not overpressure and overload.
2. Setting mode, long press SET button for 5 seconds will display P0. Press SET button shortly to set H to heating mode and C to cooling mode (up and down button to switch)
3. Set the stop temperature, press the SET button once to flash the screen, and then press the up and down keys to set the desired stop temperature.
4. Press and hold the SET button for 5 seconds to display P0, press the up and down keys to switch to P1, then press the SET button to set the difference back (press the up and down keys to adjust). If the heating mode H needs to control the temperature between 36-38 degrees , then the stop temperature is set to 38 degrees and the back difference is set to 2 (the highest temperature minus the lowest temperature)
5. Indicator light. SET light is on to indicate that the parameter is being set; OUT indicator is flashing to indicate the start delay, and always on to indicate the output.
Setting function description
Press SET button for 5 seconds to enter internal parameter setting, up and down button to switch P0-P7
Code:Code description:Setting:Factory setting
P0:Operating mode:C/H:H
P1:Backlash setting:0.1-30:2
P2:Set upper limit:Max. 110 ° C:110°C
P3:Set lower limit:Min. -50 ° C:-50°C
P4:Temperature correction:-10~10°C:0°C
P5:Delayed start:0-10 minutes:0
P6:High temperature alarm:-50~110°C:110°C
P7:Data lock:OFF/ON:OFF
P0:Heating and cooling mode H/C
The low temperature start is the heating mode, set to H. For example:the actual temperature is 21 ° C, the temperature needs to be controlled between 36-38 ° C, we set P0 to H heating mode.
The high temperature start is the cooling mode, set to C. For example:the actual temperature is 38 °C, and the temperature needs to be controlled between 24-26 °C. We set P0 to C cooling mode.
P1:Hysteresis setting
In heating mode (H):The measured value starts the output heating to the set value when the set value – hysteresis.
For example, to control an indoor temperature between 36 and 38 ° C, the actual temperature is 20 ° C, heating equipment is required to heat room, P0 is set to H, the stop temperature is set to 38 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 38-36 = 2)
In cooling mode (C):When the measured value >= set value + hysteresis, the output cooling is started until the set value stops.
For example, to control an indoor temperature between 24 and 26 ° C, the actual temperature is 36 ° C, the cooling equipment is required to cool room, P0 is set to C, the stop temperature is set to 24 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 26-24 = 2)
P2:Limit the maximum set value (non-temperature control setting):up to 110 °C
For example, if P2 is set to 50 °C, then when you set the operation, the maximum temperature can only be set to 50 °C.
P3:Limit the min. set value (non-temperature control setting):min. -50 °C
For example, if P2 is set to 20 °C, then when you set the operation, the set min. temperature can only be 20 °C. Since P2 is set to 50 degrees and P3 is set to 20 degrees, then you set is only Can be adjusted between 20~50 degrees.
P4:Temperature correction
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
For example, the probe measurement temperature is 22.8 ° C, the standard temperature is 24.2 ° C, you need to increase the height by 1.4 degrees, set P4 = 1.4
For example, the probe measurement temperature is 26.31 ° C, the standard temperature is 23.5 ° C, it needs to be lowered by 2.8 degrees, and P4 = -2.8 can be set.
P5:Delay start time:0~10 minutes
When controlling the cooling of the compressor equipment, the delay time can be set as required. When the controller outputs, the equipment will not start immediately, and it needs to be started after the set delay time has elapsed. (Non-compressor control is set to 0)
P6:High temperature alarm
When the measured value is greater than the alarm value, the screen temperature flashes and the drip sound alarm, the output is forcibly turned off in the heating mode, and the output is not turned off in the cooling mode.
P7:Data lock function
Turn on the data lock, P7 is turned ON to save the current setting parameters without being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to enter P7 to turn OFF to turn off the data lock function.
Package includes
3 x High precision microcomputer temperature controller
Weight | 0.285 kg |
---|
Customers Also Viewed
10pcs 3296W 10K ohm Trimpot Trimmer Potentiometer
$4.36Electronic Accessories & SuppliesAdd to cartSpecificationResistance:10K ohmPower (Watts):0.5W, 1/2W Tolerance:±10% Temperature Coefficient:±100ppm/°C Number of Turns:25 Adjustment Type:Top Adjustment Resistive Material:Cermet Mounting Type:Through Hole Termination Style:PC Pins Size / Dimension:9.53 x 4.83 x 10.03mmPackage included10 x Potentiometer
1090MHZ 36DB SMA Active ADS-B PCB Antenna with Biaser Tee Kit
$54.66RF amplifierAdd to cartSpecific parameters1. Omnidirectional antenna;2.The PCB circuit inside the antenna integrates a low noise amplifier;3. The PCB circuit inside the antenna integrates a filter:the bandwidth is 30MHZ;4. Length:about 22.5CM (including SMA connector);5. Equipped with ABS engineering plastic tube;6. Gain:36DB7. Frequency:1090MHzProduct included1 * ADS-B LAN antenna1 * bias1 * SMA male-SMA male cable, length:about 20cm.Special reminderWithout a …
1090MHZ 36DB SMA Active ADS-B PCB Antenna with Biaser Tee KitRead More
24V 2000W LCD Display 4 Holes Car Heater Warmer Fans Protect Window Defroster
$168.06Laboratory Heating EquipmentsAdd to cartSpecificationMaterial:metalColor:yellowSize:30x12x10cmVoltage:24VPower:2000WThe maximum temperature:about 80 ℃Features Double big fan, four holes out of the wind, super hot air Safety switch Wind speed can be adjusted Temperature display The heater size is small, easy installation, energy-saving wear and tear, low noise (almost no noise). Low power consumption, high thermal efficiency, does not affect the power of the …
24V 2000W LCD Display 4 Holes Car Heater Warmer Fans Protect Window DefrosterRead More
2500W 50A ZVS induction Heating Module High Frequency Heating Machine Melted Metal Heater + 48V Coil
$253.27ZVS Heating ModuleAdd to cartIntroductionThis version is a 2500W upgrade of the 1800W ZVS heating module, using an oversized PCB layout design and an oversized heat sink for heat dissipation.Good power, self-contained cooling fan interface, can also do Tesla discharge, mark generator, high voltage inverter power supply, etc.This product can work continuously for several hours under good heat dissipation …
DIY infrared Laser Aiming Anti-theft Burglar Alarm Module Kit
$13.11DIY Electronic KitsAdd to cartNote:This is a DIY kit, you need to assemble it, easy to install, not supply instructions.Working principleWhen no light hits the photosensitive resistor, the transistor turns on and the buzzer gets the power to start tweeting. When there is light on the photosensitive resistor, the transistor is turned off, the buzzer is powered off, stop …
DIY infrared Laser Aiming Anti-theft Burglar Alarm Module KitRead More
10pcs Modbus RTU 7-24V Relay Module RS485/TTL 1-way input and Output with Anti-reverse Protection
$67.27Relay ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.Manual:Click here to openProduct parameters1. On-board mature and stable 8bit MCU and MAX485 level conversion chip2. Communication protocol:support standard Modbus RTU protocol3. Communication interface:Support RS485 / TTL UART interface4. Communication baud rate:4800/9600/19200, …
Reviews
There are no reviews yet.