Product Name:High precision microcomputer temperature controller
Product model:XH-W1818
Temperature range:-50~110°C
Resolution:0.1 ° C
Temperature control range:-50~110°C
Temperature control accuracy:1 ° C
Temperature probe:NTC10K (B3950) L=1M
Supply voltage:DC24V
Applicable environment:-25~55°C Humidity 50%-85%
Output type:10A relay output
Appearance size:diameter 80mm
Opening size:diameter 61mm/3mm
How to use
1. Connect the power supply and load according to the instructions. Please do not overpressure and overload.
2. Setting mode, long press SET button for 5 seconds will display P0. Press SET button shortly to set H to heating mode and C to cooling mode (up and down button to switch)
3. Set the stop temperature, press the SET button once to flash the screen, and then press the up and down keys to set the desired stop temperature.
4. Press and hold the SET button for 5 seconds to display P0, press the up and down keys to switch to P1, then press the SET button to set the difference back (press the up and down keys to adjust). If the heating mode H needs to control the temperature between 36-38 degrees , then the stop temperature is set to 38 degrees and the back difference is set to 2 (the highest temperature minus the lowest temperature)
5. Indicator light. SET light is on to indicate that the parameter is being set; OUT indicator is flashing to indicate the start delay, and always on to indicate the output.
Setting function description
Press SET button for 5 seconds to enter internal parameter setting, up and down button to switch P0-P7
Code:Code description:Setting:Factory setting
P0:Operating mode:C/H:H
P1:Backlash setting:0.1-30:2
P2:Set upper limit:Max. 110 ° C:110°C
P3:Set lower limit:Min. -50 ° C:-50°C
P4:Temperature correction:-10~10°C:0°C
P5:Delayed start:0-10 minutes:0
P6:High temperature alarm:-50~110°C:110°C
P7:Data lock:OFF/ON:OFF
P0:Heating and cooling mode H/C
The low temperature start is the heating mode, set to H. For example:the actual temperature is 21 ° C, the temperature needs to be controlled between 36-38 ° C, we set P0 to H heating mode.
The high temperature start is the cooling mode, set to C. For example:the actual temperature is 38 °C, and the temperature needs to be controlled between 24-26 °C. We set P0 to C cooling mode.
P1:Hysteresis setting
In heating mode (H):The measured value starts the output heating to the set value when the set value – hysteresis.
For example, to control an indoor temperature between 36 and 38 ° C, the actual temperature is 20 ° C, heating equipment is required to heat room, P0 is set to H, the stop temperature is set to 38 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 38-36 = 2)
In cooling mode (C):When the measured value >= set value + hysteresis, the output cooling is started until the set value stops.
For example, to control an indoor temperature between 24 and 26 ° C, the actual temperature is 36 ° C, the cooling equipment is required to cool room, P0 is set to C, the stop temperature is set to 24 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 26-24 = 2)
P2:Limit the maximum set value (non-temperature control setting):up to 110 °C
For example, if P2 is set to 50 °C, then when you set the operation, the maximum temperature can only be set to 50 °C.
P3:Limit the min. set value (non-temperature control setting):min. -50 °C
For example, if P2 is set to 20 °C, then when you set the operation, the set min. temperature can only be 20 °C. Since P2 is set to 50 degrees and P3 is set to 20 degrees, then you set is only Can be adjusted between 20~50 degrees.
P4:Temperature correction
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
For example, the probe measurement temperature is 22.8 ° C, the standard temperature is 24.2 ° C, you need to increase the height by 1.4 degrees, set P4 = 1.4
For example, the probe measurement temperature is 26.31 ° C, the standard temperature is 23.5 ° C, it needs to be lowered by 2.8 degrees, and P4 = -2.8 can be set.
P5:Delay start time:0~10 minutes
When controlling the cooling of the compressor equipment, the delay time can be set as required. When the controller outputs, the equipment will not start immediately, and it needs to be started after the set delay time has elapsed. (Non-compressor control is set to 0)
P6:High temperature alarm
When the measured value is greater than the alarm value, the screen temperature flashes and the drip sound alarm, the output is forcibly turned off in the heating mode, and the output is not turned off in the cooling mode.
P7:Data lock function
Turn on the data lock, P7 is turned ON to save the current setting parameters without being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to enter P7 to turn OFF to turn off the data lock function.
Package includes
3 x High precision microcomputer temperature controller
Weight | 0.285 kg |
---|
Customers Also Viewed
18v 15w 410mm*200mm*3mm Semi-flexible Solar Panel with Cable for off-road Vehicle Outdoor Working
$62.25Smart Robot & Solar PanelAdd to cartFeatures– Durable with PET backsheet, no glass.– Unique frameless design includes 4metal reinforced mounting holes for easy installation– Light weight,easy carrying,easy shipment,easy installation.– Thin:the thickness is only 3mm, easy joint to your yacht or RV roof , boat etc.– Solar energy conversion rate up to 19.6-20%– Rounding corners to prevent from being scratched.Hardening process surface …
RX HF 1-50MHz Durable Portable Antenna Splitter Radio Communication BNC Connectors Home Professional Metal
$29.96Other Module BoardAdd to cartFeaturesHF Antenna RX splitter has one antenna port and two receivers ports.Frequency range:100kHz-50 Mhz. Impedance (I/O)-50 Ohm.SpecificationsMaterial:Metal, PlasticColor:As ShownTypes:Finished ProductFrequency range:100kHz-50 MhzImpedance (I/O)-50 OhmAverage port to port isolation measured-36 dBAverage signal attenuation(loss)-3.2 dBConnectors type-BNCSize:(Approx) 150*150*50mmPackage Included1 x Antenna Splitter RX HF 1-50 MHz
3Pcs DIY LED Lamp Kit LED Flash Set Electronic Production Kit
$30.16DIY Electronic KitsAdd to cartFeatureKit Model:LSD-73Dimensions:100 * 80mmWorking voltage:DC4-5VPackage weight:55 gramsNote:This is a DIY kit, you need to assemble it, to get the installation document.Package includes3 x DIY LED Lamp KitSoldered PCB, for reference only!
12V 300W Portable Diesel Fuel Oil Transfer Pump Self Priming Oil Pump 50L/Min
$200.46Electrical Pump & ValveAdd to cart12V Portable Fuel Diesel Pump Oil Transfer Pump Self Priming 50L/Min 300WSpecificationsMaterial:Pure copper motor + cast ironQuantity:1 setLift distance:15mAbsorbing distance:5mRotate Speed:5000R/minFlow Rate:50L/minVoltage:12VPower:300WProduct dimension:20cm x 14cm x 10cm (Approx.)Package size:30 x 16 x 17cm(Approx.)Used for pumping, oil, kerosene and diesel oil.Not suitable for petrol.Features-Self priming.-Low working noise.-Powerful 12Volt 300W motor.-With handle so it is easy to …
12V 300W Portable Diesel Fuel Oil Transfer Pump Self Priming Oil Pump 50L/MinRead More
5Pcs Geekcreit 36 Value Electronic Components Storage Assortment Box
$84.81Electronic Accessories & SuppliesAdd to cartDescriptionFormat size of this electronic components assortment box can be assembled arbitrary, varies of intervals designed to facilitate access to small parts and store, pick parts very easy.Specification36 value:27.0 x 17.5 x 4.5cmPackage included5 x Electronic components assortment box
5Pcs GPIO Pin Reference Board for Raspberry Pi 2 Model B & Raspberry Pi B+
$17.24Raspberry Pi & Orange PiAdd to cart5Pcs GPIO Pin Reference Board For Raspberry Pi 2 Model B & Raspberry Pi B+FeatureCompatible with Raspberry Pi 2 Model B & Raspberry Pi B+Material:PCBWith marked you can easily distinguish all leads of GPIODimensions:5.3 cm x 1 cm x 0.1 cmPackage included5 x GPIO Pin Reference Board
Plantower PMS7003 G7 PM2.5 Sensor Laser Particle Sensor Detector Air Quality Tester
$56.85Sensor & Detector ModuleAdd to cartFeatureParameter:Index:UnitParticulate matter measurement range:0.3 ~ 1.0; 1.0 ~ 2.5; 2.5 ~ 10:Micrometer (um)Particle counting efficiency:50% @ 0,3 microns 98% @> = 0.5 micronsEffective range of particulate matter concentration (PM2.5 standard value):0-500:Μg / m3Particulate matter concentration resolution:1:Μg / m3Particulate matter concentration consistency (PM2.5 standard value) *:± 10% @ 100 ~ 500μg / m3± 10 μg / …
Plantower PMS7003 G7 PM2.5 Sensor Laser Particle Sensor Detector Air Quality TesterRead More
Reviews
There are no reviews yet.