5pcs 110-220V XH-W1818 High Precision Microcomputer Temperature Controller Circular Digital Display Embedded thermostat
$81.24
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Feature
Product Name:High precision microcomputer temperature controller
Product model:XH-W1818
Temperature range:-50~110°C
Resolution:0.1 ° C
Temperature control range:-50~110°C
Temperature control accuracy:1 ° C
Temperature probe:NTC10K (B3950) L=1M
Supply voltage:AC220V
Applicable environment:-25~55°C Humidity 50%-85%
Output type:10A relay output
Appearance size:diameter 80mm
Opening size:diameter 61mm/3mm
How to use
1. Connect the power supply and load according to the instructions. Please do not overpressure and overload.
2. Setting mode, long press SET button for 5 seconds will display P0. Press SET button shortly to set H to heating mode and C to cooling mode (up and down button to switch)
3. Set the stop temperature, press the SET button once to flash the screen, and then press the up and down keys to set the desired stop temperature.
4. Press and hold the SET button for 5 seconds to display P0, press the up and down keys to switch to P1, then press the SET button to set the difference back (press the up and down keys to adjust). If the heating mode H needs to control the temperature between 36-38 degrees , then the stop temperature is set to 38 degrees and the back difference is set to 2 (the highest temperature minus the lowest temperature)
5. Indicator light. SET light is on to indicate that the parameter is being set; OUT indicator is flashing to indicate the start delay, and always on to indicate the output.
Setting function description
Press SET button for 5 seconds to enter internal parameter setting, up and down button to switch P0-P7
Code:Code description:Setting:Factory setting
P0:Operating mode:C/H:H
P1:Backlash setting:0.1-30:2
P2:Set upper limit:Max. 110 ° C:110°C
P3:Set lower limit:Min. -50 ° C:-50°C
P4:Temperature correction:-10~10°C:0°C
P5:Delayed start:0-10 minutes:0
P6:High temperature alarm:-50~110°C:110°C
P7:Data lock:OFF/ON:OFF
P0:Heating and cooling mode H/C
The low temperature start is the heating mode, set to H. For example:the actual temperature is 21 ° C, the temperature needs to be controlled between 36-38 ° C, we set P0 to H heating mode.
The high temperature start is the cooling mode, set to C. For example:the actual temperature is 38 °C, and the temperature needs to be controlled between 24-26 °C. We set P0 to C cooling mode.
P1:Hysteresis setting
In heating mode (H):The measured value starts the output heating to the set value when the set value – hysteresis.
For example, to control an indoor temperature between 36 and 38 ° C, the actual temperature is 20 ° C, heating equipment is required to heat room, P0 is set to H, the stop temperature is set to 38 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 38-36 = 2)
In cooling mode (C):When the measured value >= set value + hysteresis, the output cooling is started until the set value stops.
For example, to control an indoor temperature between 24 and 26 ° C, the actual temperature is 36 ° C, the cooling equipment is required to cool room, P0 is set to C, the stop temperature is set to 24 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 26-24 = 2)
P2:Limit the maximum set value (non-temperature control setting):up to 110 °C
For example, if P2 is set to 50 °C, then when you set the operation, the maximum temperature can only be set to 50 °C.
P3:Limit the min. set value (non-temperature control setting):min. -50 °C
For example, if P2 is set to 20 °C, then when you set the operation, the set min. temperature can only be 20 °C. Since P2 is set to 50 degrees and P3 is set to 20 degrees, then you set is only Can be adjusted between 20~50 degrees.
P4:Temperature correction
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
For example, the probe measurement temperature is 22.8 ° C, the standard temperature is 24.2 ° C, you need to increase the height by 1.4 degrees, set P4 = 1.4
For example, the probe measurement temperature is 26.31 ° C, the standard temperature is 23.5 ° C, it needs to be lowered by 2.8 degrees, and P4 = -2.8 can be set.
P5:Delay start time:0~10 minutes
When controlling the cooling of the compressor equipment, the delay time can be set as required. When the controller outputs, the equipment will not start immediately, and it needs to be started after the set delay time has elapsed. (Non-compressor control is set to 0)
P6:High temperature alarm
When the measured value is greater than the alarm value, the screen temperature flashes and the drip sound alarm, the output is forcibly turned off in the heating mode, and the output is not turned off in the cooling mode.
P7:Data lock function
Turn on the data lock, P7 is turned ON to save the current setting parameters without being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to enter P7 to turn OFF to turn off the data lock function.
Package includes
5 x High precision microcomputer temperature controller
Weight | 0.45 kg |
---|
Customers Also Viewed
B0505XT-2WR2 5V to 5V Isolation Power Supply Chip Module input 4.5-5.5V Output 5V
$8.78Power Supply ModuleAdd to cart>>>Manual:Click here to openOverviewThe B_XT-2WR2 family is designed for applications in board power systems that require a set of voltages that are isolated from the input supply. This product is suitable for1. The input power supply voltage is relatively stable (voltage variation range ±10% Vin);2. Requirements isolation between input and output (isolation voltage ≤ 1500VDC);3. …
B0505XT-2WR2 5V to 5V Isolation Power Supply Chip Module input 4.5-5.5V Output 5VRead More
550W 120mm Fan ATX SATA PCI-E Power Supply for intel AMD PC Unit
$111.36Voltage Regulators/StabilizersAdd to cartSpecificationPower standard::ATX 12VFor CPU range::AMD, IntelPFC type::Passive PFCVoltage:170V-270VRated power:550WAuthentication::CB, CCC, FCC, class, B, CE, ROHSProduct weight::1228gSupport system::VISTA, Win7 operating systemSupport power supply::20P and 24P motherboardPower output design:Multiplex +12VIDE interface:3SATA interface:3CPU interface::8 pins*1Video card interface::6P*1Feature-High efficiency energy-saving silent fan.-Adopt 12cm hydraulic bearing fan, mute and durable, large air flow.-Maximum power of 550 watts, suitable for high-end …
550W 120mm Fan ATX SATA PCI-E Power Supply for intel AMD PC UnitRead More
5Pcs Waterproof 12-60V Electric Universal Battery Voltage Meter Battery Power indicator 12V/24V/36V/48V – Blue
$48.44Electronic Accessories & SuppliesAdd to cartDescriptionVoltage tolerance:± 2%8-level:10% 25% 40% 50% 60% 75% 90% fullWorking current:5–15 maRefresh speed:about 300mS onceDisplay mode:Three 0.56 inchLED digital tubeDisplay color:BlueLead length:15cmDimensions:58 * 29 * 23mm length X width X thicknessCut-out size:55 * 27mmWorking temperature:-10 → ~ 65 →Package included5 x Waterproof 12-60V Electric Universal Battery Voltmeter
10pcs 5V 2 Channel Relay Module Control Board with Optocoupler Protection
$32.80Relay ModuleAdd to cartFeaturesThe capacity of relay contact:250V 10AWith Opto-couplers protection, it is suitable for .Rated current:60mAInput voltage:0~5VVCC system power supply.Type:2 channel relay module.Package included10 x Two-way relay module
10Pcs Length 150mm OD 7mm 2mm Thick Wall Borosilicate Glass Blowing Tube Lab Factory School Home
$22.26Lab TubesAdd to cartDescriptionHigh quality borosilicate glass, Premium 3.3 borosilicate tubing, preferred by scientific glassblowers world-wide.HEAVY wall tubing 10 pieces, 7mm outside diameter with a 2mm wall – all approximately 150mm long. This glass tube bends easily with propane (LPG) and oxygen mix. Brand new, high quality, heat and corrosion resistant.SpecificationName:10Pcs 150mm OD 7mm 2mm Thick Wall Borosilicate …
51Single Chip + HC-SR04 Ultrasonic Ranging Sensor Module Ultrasonic Range Finder Reversing Radar Alarm with Display
$19.67Sensor & Detector ModuleAdd to cart>>>Manual:Click here to openDescriptionsThe ultrasonic range finder of single chip microcomputer is designed by single chip microcomputer + HC-SR04 ultrasonic sensor + digital tube + button + buzzer.1. Button description:From the first one on the left, – button, + button, setting button.2. Single-chip model:STC89C52/51, AT89S52 optional, default STC89C52.3. The alarm distance can be set. After …
3Pcs DC-DC 9V/12V/24V/36V To 5V Dual USB Buck Module Vehicle Charging Solar 3A Voltage Regulator
$19.95Boost & Buck ModuleAdd to cartDescriptionInput:6-40V(5.5*2.1mm plug)Output:5V/3A MAX(with Iphone identification resistor)Efficiency:92% MAXSwitching frequency:150KHzWorking temperature:-40→-85→Size:50*35*12mmLoad capacity:Max output 3A (can charge two mobile phones at the same time)Scope of application:mobile power, mobile phones, tablet, USB5V power supply equipmentPackage included3 x Dual USB Buck Module
12V DC infrared Remote Control Full-function Precision Delay Cycle Timing Relay Module with LED Digital Display with Remote Controller
$13.11Relay ModuleAdd to cart>>>Manual:Click here to openFeatures-The product delay time can be set by the remote control. After setting, it will display and work according to the set value countdown after the next power-on;-Delay time is 0.1% per second, delay range is 0-999 seconds, LED changes every 1 second; delay range is 0-999 minutes, LED digital display changes …
Reviews
There are no reviews yet.