XY-DJ01 DC6-30V 30A 1CH Digital Display Relay Module Delayed Power off Trigger Delay Cycle Timing Circuit Switch Rail Type
$26.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;
2. Support button trigger control, high and low level trigger, switch value control, support NPN, PNP sensor access, suitable for most occasions;
3. Wide voltage supply (6~30V),Rail installation, very convenient to use;
4. There is a key pausing function, with reverse connection protection, reverse connection does not burn;
5. Added sleep mode. After enabling, without any operation for about 5 minutes, the LCD backlight will be automatically turned off; any key to wake up;
6. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
7. All set parameters are automatically saved after power-off.
Operating mode
P0:After the signal is triggered, the relay is turned on for OP time, and then off; within the OP time, the signal is triggered again invalid
P1:After the signal is triggered, the relay is turned on for OP time and then off; within the OP time, the signal is triggered again to re-timing
P2:After the signal is triggered, the relay is turned on for OP time and then turned off; within the OP time, the signal triggers reset again, the relay is turned off, and the timing stops
P3:After the signal is triggered, the relay is turned off for CL time, and then the relay is turned on;
P4:After the trigger signal is given, the relay is turned on for OP time, the relay is disconnected for CL time, and then the above actions are cycled, the signal is given again in the cycle, the initial state is restored, and the timing is stopped; the number of cycles (LOP) can be set; the cycle ends, keep the relay off ;
P5:Give the trigger signal, after the relay is disconnected from the CL time, the relay will be turned on for OP time, and then cycle the above actions, give the signal again in the cycle, restore the initial state, and stop timing; the number of cycles (LOP) can be set; the cycle ends, keep the relay on ;
P6:After power-on, no trigger signal is needed, the relay is on for OP time, the relay is off for CL time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle is over, keep the relay off;
P7:There is no need to trigger signal after power-on, the relay is off CL time, the relay is on OP time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle ends and the relay is kept on;
P8:Signal hold function If there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing OP; during the timing, there is a signal again, and the timer is clear;
P9:Signal hold function If there is a trigger signal, the timer is cleared and the relay remains off; when the signal disappears, the relay is turned on after timing CL; during the timing, there is another signal, and the timer is cleared;
(P0~P7) mode, short press the pausing button, when the system does not trigger the timing, the system starts timing; when the system is already timing, the system pauses timing, the relay is disconnected, and flashes ‘OUT’ as a reminder;
In P8 P9 mode, the pausing button on the running interface is used as the trigger signal, and its button function is disabled by short press/long press;
Product parameter
Working voltage:6-30V power supply
Trigger signal source:high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
Output capacity:can control equipment within DC 30v 30A or AC 220v 30A
Quiescent current:15mA
Working current:50-130mA
Service life:more than 100,000 times;
Working temperature:-40-85→;
With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters are always remembered after power failure.
Timing range
0.01 second (minimum) ~ 9999 minutes (maximum) continuously adjustable
How to choose the timing range
In the OP/CL parameter modification interface, short press the pausing button to select the timing range;
XXXX No decimal point, timing range 1 second~9999 seconds
XXX.X The decimal point is in the tenth place, and the timing range is 0.1 seconds to 999.9 seconds
XX.XX The decimal point is in hundreds, and the timing range 0.01 seconds to 99.99 seconds
X.X.X.X All decimal points are lit, timing range 1 minute to 9999 minutes
For example, if you want to set the OP to 3.2 seconds, move the decimal point to the tens place, and the LCD will display 003.2
Parameter description:OP on time, CL off time, LOP cycle times (1-9999 times, ‘—-‘ represents infinite cycles)
parameter settings
a) Enter the setting interface by long pressing the setting button;
b) First set the work mode, the work mode flashes to remind, short press the increase/decrease button to set the work mode;
c) Short press the setting button, select the working mode, and enter the system parameter setting;
d) In the system parameter setting interface, short press the setting button to switch the system parameter to be modified, and short press/long press the increase/decrease button to modify;
(Note:Short press the setting button is invalid in P0~P3/P8/P9 mode);
e) In the OP/CL parameter modification interface, short press the pausing button to switch the timing unit (1s/0.1s/0.01s/1min)
f) After setting all parameters, long press the setting button to save the parameter setting and exit the setting interface;
Additional functions
a)Automatic sleep function:In the running interface (P0~P7 mode), long press the pausing button to start or close the automatic sleep function (LP selects on to start the sleep function, about five minutes, without any operation, the LCD backlight automatically turns off , The system is running normally, any key is pressed to wake up; off is to close the sleep function);
b) Parameter view:In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;
c) Display content switching:In P4 ~ P7 mode, short press the DOWN key to switch the display content (operating time/cycle times);
Package included
1 x Relay Module Switch
Weight | 0.03 kg |
---|
Customers Also Viewed
3pcs DC 1.8V 3V 5V 6V 12V 2A PWM Motor Speed Controller 0~100% Adjustable Drive Module 1803B
$14.99Motor PWM Speed ControllerAdd to cartFeatureThe input power range is DC 1.8-15V . Use a 2A resettable fuse to protect the controller.Potentiometer with switch function. Operating instruction:Before you attempting to wire the controller, make sure power is off.WARNING:TO CHANGE MOTOR DIRECTION, INTERCHANGE THE POSITIVE AND NEGATIVE WIRES OF MOTOR. Turn on the power, and adjust the potentiometer. The LED indicates …
Flax Liner Cloth Fiber Cloth Bakers Proofing Couche for Proving Bread Pans Kitchen Tool Fermentation
$19.83FabricsFibers & TextilesAdd to cartDescriptionThis flax liner cloth is made of flax linen material, natural, untreated, unbleached.SpecificationMaterial:Flax LinenColor:As picture shownSize:(L)X(W)45X36cm/17.72inchX14.17inch(appr.)Features1.Made of flax linen material, natural, untreated, unbleached.2. A couche is used to proof the bread.3. Plenty of surface to work multiple loaves.4. Do not bake in oven. It can not withstand the heat.5. Finished seam on both sides so …
99900W 12V Smart Ultrasonic inverter Electro Fisher Fishing Machine Ultrasonic inverter Safe Protection Fisher Fishing Shocker 20 Field Tube
$170.09InvertersAdd to cartSpecificationsColor:BlackDrive:Intelligent drive computer boardSecurity protection:12 intelligent security protectionsScope of application:1-3mApplicable depth:3mThyristor:2 * energy-efficient siliconPower field tube:20Applicable battery:12V 45A or moreProduct net weight:1.8KGSize:290 * 60 * 145mmOverload Protection:Yes (120A)Low Voltage Protection:Yes (Less than 9V/DC protection )High Voltage Protection:Yes (Exceed 15V/DC protection )Over-temperature Protection:85°CFeatures– Short-circuit Protection&Reverse Polarity Protection&Waterproof Protection.– High power& Low energy consumption& Excellent results, the …
CMP03 3A-12V Charge and Discharge Controller Solar Charge Controller Solar Panel
$30.36Solar ControllersAdd to cartSpecificationModel:CMP03Rated Voltage:DC12VMax Current:3Avoltage of solar panels:36W(3A,12v)Charge-stop Voltage:14.4VCoefficient of Stop Voltage and Temp:-3mV/degree/cellSupply-stop Voltage:10.6VSupply-resume Voltage:12VLight Control Mode:Visibility 20MWorking Temp:-10- +40degree;Weight:33gFunction1. Prevent the battery from over charging, over discharging and Reverse discharging to solar panel during nights.2. Controller will start the lighting system in the evening automatically according to the surrounding luminance.Indicator1. One charging indicator, light indicates …
CMP03 3A-12V Charge and Discharge Controller Solar Charge Controller Solar PanelRead More
8 PCS Diving Equipment SMACO Scuba Diving Cylinder Oxygen Reserve Air Tank
$443.46Electrical Pump & ValveAdd to cartSpecificationBreathing Oxygen Cylinder Capacity:0.5L Material:Aviation Aluminum Oxygen Cylinder Weight:1040g Oxygen Cylinder Dimension:φ6*35.5cm (2.4*14′) Air Capacity:3.0 Cu.Ft / 85 Litters Max. Pressure:3000Psi / 200bar / 20MpaMax. Dwell Time Underwater:10mins Pumping Time:7-10min Features1. The 0.5L Oxygen Cylinder Allows The Diver To Stay 7 Meters Underwater For 6-10 Minutes (Depending On Individual Lung Capacity And Depth Of Diving), …
8 PCS Diving Equipment SMACO Scuba Diving Cylinder Oxygen Reserve Air TankRead More
5pcs 40x40mm thermoelectric Power Generator Peltier Module TEG High Temperature 150 Degree
$30.60Electronic Accessories & SuppliesAdd to cartFeatureColding side posts with the wordsHeating side is emptyRed wire to positive, black wire to the negative, it generate electricity when the temperature difference happenedSpecificationModel:SP1848-27145 Color:whiteLead Length:about 30CMSize:40MM x 40MM x 3.4MM20 degree temperature difference:open-circuit voltage 0.97V, generated current:225MA40 degree temperature difference:open circuit voltage 1.8V, generated current:368MA60 degree temperature difference:open circuit voltage 2.4V, generated current:469MA80 …
5pcs 40x40mm thermoelectric Power Generator Peltier Module TEG High Temperature 150 DegreeRead More
Reviews
There are no reviews yet.