Features
1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;
2. Support button trigger control, high and low level trigger, switch value control, support NPN, PNP sensor access, suitable for most occasions;
3. Wide voltage supply (6~30V),Rail installation, very convenient to use;
4. There is a key pausing function, with reverse connection protection, reverse connection does not burn;
5. Added sleep mode. After enabling, without any operation for about 5 minutes, the LCD backlight will be automatically turned off; any key to wake up;
6. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
7. All set parameters are automatically saved after power-off.
Operating mode
P0:After the signal is triggered, the relay is turned on for OP time, and then off; within the OP time, the signal is triggered again invalid
P1:After the signal is triggered, the relay is turned on for OP time and then off; within the OP time, the signal is triggered again to re-timing
P2:After the signal is triggered, the relay is turned on for OP time and then turned off; within the OP time, the signal triggers reset again, the relay is turned off, and the timing stops
P3:After the signal is triggered, the relay is turned off for CL time, and then the relay is turned on;
P4:After the trigger signal is given, the relay is turned on for OP time, the relay is disconnected for CL time, and then the above actions are cycled, the signal is given again in the cycle, the initial state is restored, and the timing is stopped; the number of cycles (LOP) can be set; the cycle ends, keep the relay off ;
P5:Give the trigger signal, after the relay is disconnected from the CL time, the relay will be turned on for OP time, and then cycle the above actions, give the signal again in the cycle, restore the initial state, and stop timing; the number of cycles (LOP) can be set; the cycle ends, keep the relay on ;
P6:After power-on, no trigger signal is needed, the relay is on for OP time, the relay is off for CL time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle is over, keep the relay off;
P7:There is no need to trigger signal after power-on, the relay is off CL time, the relay is on OP time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle ends and the relay is kept on;
P8:Signal hold function If there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing OP; during the timing, there is a signal again, and the timer is clear;
P9:Signal hold function If there is a trigger signal, the timer is cleared and the relay remains off; when the signal disappears, the relay is turned on after timing CL; during the timing, there is another signal, and the timer is cleared;
(P0~P7) mode, short press the pausing button, when the system does not trigger the timing, the system starts timing; when the system is already timing, the system pauses timing, the relay is disconnected, and flashes ‘OUT’ as a reminder;
In P8 P9 mode, the pausing button on the running interface is used as the trigger signal, and its button function is disabled by short press/long press;
Product parameter
Working voltage:6-30V power supply
Trigger signal source:high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
Output capacity:can control equipment within DC 30v 30A or AC 220v 30A
Quiescent current:15mA
Working current:50-130mA
Service life:more than 100,000 times;
Working temperature:-40-85→;
With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters are always remembered after power failure.
Timing range
0.01 second (minimum) ~ 9999 minutes (maximum) continuously adjustable
How to choose the timing range
In the OP/CL parameter modification interface, short press the pausing button to select the timing range;
XXXX No decimal point, timing range 1 second~9999 seconds
XXX.X The decimal point is in the tenth place, and the timing range is 0.1 seconds to 999.9 seconds
XX.XX The decimal point is in hundreds, and the timing range 0.01 seconds to 99.99 seconds
X.X.X.X All decimal points are lit, timing range 1 minute to 9999 minutes
For example, if you want to set the OP to 3.2 seconds, move the decimal point to the tens place, and the LCD will display 003.2
Parameter description:OP on time, CL off time, LOP cycle times (1-9999 times, ‘—-‘ represents infinite cycles)
parameter settings
a) Enter the setting interface by long pressing the setting button;
b) First set the work mode, the work mode flashes to remind, short press the increase/decrease button to set the work mode;
c) Short press the setting button, select the working mode, and enter the system parameter setting;
d) In the system parameter setting interface, short press the setting button to switch the system parameter to be modified, and short press/long press the increase/decrease button to modify;
(Note:Short press the setting button is invalid in P0~P3/P8/P9 mode);
e) In the OP/CL parameter modification interface, short press the pausing button to switch the timing unit (1s/0.1s/0.01s/1min)
f) After setting all parameters, long press the setting button to save the parameter setting and exit the setting interface;
Additional functions
a)Automatic sleep function:In the running interface (P0~P7 mode), long press the pausing button to start or close the automatic sleep function (LP selects on to start the sleep function, about five minutes, without any operation, the LCD backlight automatically turns off , The system is running normally, any key is pressed to wake up; off is to close the sleep function);
b) Parameter view:In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;
c) Display content switching:In P4 ~ P7 mode, short press the DOWN key to switch the display content (operating time/cycle times);
Package included
1 x Relay Module Switch
Weight | 0.03 kg |
---|
Customers Also Viewed
3Pcs MPR121-Breakout-v12 Proximity Capacitive Touch Sensor Controller Keyboard Development Board
$16.16Motherboard & Development BoardAdd to cartDescriptionThis is a breakout board for Freescale’s MPR121QR2. The MPR121 is a capacitive touch sensor controller driven by an I2C interface.The chip can control up to twelve individual electrodes, as well as a simulated thirteenth electrode. The MPR121 also features eight LED driving pins. When these pins are not configured as electrodes, they may be …
220V 100A Class A Power Amplifier Soft Start Delay Temperature Protection Board with Gas Discharge Tube
$24.95Relay ModuleAdd to cartFeatures100% Brand new and high quality.FunctionThe board is equipped with a gas discharge tube. The gas discharge tube is composed of a pair of cold cathode plates which are separated from each other and enclosed in a ceramic tube filled with a certain inert gas (Ar).The gas discharge tube is turned off under normal operating …
Excellway Terminals 40 Pcs 2p 3p 4p 5pin Right angle JST-XH Male Female Lipo Balance Connector
$36.44ConnectorsAdd to cartSpecificaiton Brand:Excellway Pitch:2.54mm Current Rating:1A AC, DC Voltage Rating:125V AC, DC Temperature Range:-25 deg C ~ +85 deg C Insulation Resistance:100M Omega Min. Wire Range:AWG 24~ 32 Insulation O.D.:1.00mm ( Max.) Withstanding Voltage:500V AC/minute Features These work great with all your typical and breadboard style pin connectors and sockets. This kit comes with the most …
HBV-1466FF Fixed Focus 5MP OV5640 FPC Camera Module USB 5 Million Pixels IP Camera Module
$42.85Other Module BoardAdd to cartSpecificationsModel No.:HBVCAM-1466FFModel Size:68.2mm ≠ 26mm ≠ 6mm÷0.2MMTemperature (Operation):-30C to 70CTemperature (Stable Image):0C to 50CAssembly technique:SMT (ROSH)Focus:FixedObject distance:30CM-infinitResolution:800LW/PH (Center)Interface:USB 2.0Power:USB bus powerMaximum Power consumption:940 mWPackage:Anti-electrostatic trayOperating system request:Win XP/win 7,8 / vista /android 4.0/ mac /Linuxwith uvcCertifications:FCC and CEActive Array Size:2592*1944Sensor:OV5640 (1/4” )Sensitivity:600mv /(lux-sec)Pixel Size:1.4┢m x1.4┢mMaximum Image Transfer Rate:MJPEG 1024×768 30FPS / YUY2 160×120 30FPSMJPEG 1280×720 …
HBV-1466FF Fixed Focus 5MP OV5640 FPC Camera Module USB 5 Million Pixels IP Camera ModuleRead More
10pcs 40x40mm Small Fan 4010S Computer Chassis CPU Fan 2 Line with Plug
$19.84Electronic Accessories & SuppliesAdd to cartDescriptionAppearance size:40mm x 40mm x 10mmSpeed reference:4000 ± 10% RPMNoise Reference:18DBAir volume reference:18.17-25.97CFMRated voltage:12VRated current:0.10APackage included10 x Fan
Reviews
There are no reviews yet.