3Pcs J03 LED Digital Time Delay Relay DC 6-30V on off Trigger Delay Timming Timer Switch Micro USB Power Supply 5V 12V
$32.79
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. Wide voltage power supply (6 ~ 30V), supports microUSB 5.0V power supply, easy to use;
2. The interface is clear and simple, powerful, easy to understand, meet almost all your needs;
3. The emergency stop function (“STOP’key);With reverse polarity protection, reverse polarity will not burn the product.
4. Increase the sleep mode, if this mode is enabled, without any operation within 5 minutes, then automatically turn off the monitor, any key wake-up;
5. You can set a different OP, CL, LOP parameters, which are independent of each other, and are automatically saved;
6. After the module is powered down, all parameter settings are not lost.
Product parameters
1:Operating voltage:6–30V, support microUSB 5.0V power supply
2:Trigger Source:Active-high (3.0V-24V), have optocoupler isolation, can improve the system’s anti-jamming capability (customers can also shorting common ground).
3:Output capability:You can control the DC 30VDC 5A or 220VAC 5A device.
4:Quiescent Current:20mA; Operating Current:50mA
5:Life:more than 10 million times; Working temperature:-40→-85 →; Size:6.2*3.8*1.7cm.
6:With optocoupler isolation, enhanced anti-jamming capability, industrial grade board.
Special Note:The relay outputs are passive contact, just a switch.
Operating mode
P1:trigger signal, the relay is on ‘OP’ time, and then disconnect; in the ‘OP’ time, as follows
P1.1:signal is triggered again, invalid
P1.2:signal is triggered again, the clock is reset
P1.3:Signal trigger again, relay off, stop the clock;
P-2:trigger signal, the relay off ‘CL’ of time, the relay on ‘OP’ time, and then disconnect relay;
P3.1:trigger signal, the relay is turned on after the ‘OP’ time, the relay off ‘CL’ time, then the operation cycle, if the trigger signal period, the relay off, stop the clock; the number of cycles ( ‘LOP ‘) can be set.
P3.2:without triggering signal, the relay is on ‘OP’ time, the relay off ‘CL’ time, and has been cycling; frequency ( ‘LOP’) cycle can be set;
P-4:signal holding function. If there is a trigger signal timing is cleared, the relay remains on; when the signal disappears, after the timing ‘OP’ time, the relay is; if another signal during timing, timing is cleared.
Timing range
0.1 seconds (min) to 999 minutes (max) continuously adjustable
How to choose the time range
After setting the mode selection screen parameter value by a short press ‘STOP’ button to select the time range;
XXX. decimal point in the unit place, time range:1 second to 999 seconds.
XX. X decimal point in decade place, Timing range:0.1 seconds to 99.9 seconds
X. X. X. decimal full brightness, Timing range:1 minute to 999 minutes.
For example, you want to set ‘OP’ is 3.2 seconds, then move the decimal point to decade place, the digital display 03.2
Parameter description:’OP’ – conduction time, ‘CL’ – off time, ‘LOP’ – the number of cycles (1-999 times, ‘—‘ represents infinite loop).
These parameters are independent of each other, but is shared by each mode. For example, in P1.1 mode, set the on-time ‘OP’ is 5 seconds, if you switch to P1.2 mode, it’s ‘OP’ will be 5 seconds too.
In the main interface (display 000), short press ‘SET’ button will display ‘OP’ ( ‘CL’, ‘LOP’) and the corresponding time XXX;
Some parameters only mode ‘OP’ (such as the mode P1.1, P1.2, P1.3), short press the ‘SET’ key to display only the “OP” and the corresponding time;
Some models have parameters ‘OP’,’CL’, ‘LOP’ (such as the mode P3.1, P3.2), short press ‘SET’ button will display ‘OP’ and the corresponding time, “CL” and the corresponding time, “LOP” and the corresponding number of times;
In the main interface by short press ‘SET’ key to see information about the parameters of the current mode, very convenient!
How to set parameters
1. First, read the instructions to determine the required operating mode.
2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press ‘SET’ button for 2 seconds after release to enter mode selection interface; a short time by pressing ‘UP’, ‘DOWN’ key to select the mode (P1.1 ~ P-4).
3. Select the mode (such as P3.2), short press the ‘SET’ button, then the parameter to be set flashes ( ‘OP’on-time, ‘CL’ off time, ‘LOP’ cycles ( ‘—‘ represents infinite loop)), by ‘UP’, ‘DOWN’ keys to adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease one unit); then short press the ‘STOP’ key to select the decimal point position, select the time range (0.1 seconds to 999 minutes); short press the ‘SET’ button to set the next parameters of the current mode of procedure is as above.
4. After the parameters are set, long press ‘SET’ button for 2 seconds then release, the name of the current mode will flash once, and then return to the main screen, set the parameters of success!
The main interface:In the relay does not work status display ‘000’ (no decimal point), with a decimal point under relay state.
Mode selection screen:Long press the ‘SET’ key to enter, after setting is completed, long press the ‘SET’ key to exit back to the main screen.
‘STOP’ button extensions
Relays enable mode
1. ON:Relay allows conduction in the ‘OP’ on-time;
2. OFF:relay prohibit conduction is always closed;
In the main interface, short press the ‘STOP’ button to switch between ON and OFF, the current in which the state will flash, and then return to the main screen. (This feature is an emergency stop function, click off the relay)
Sleep mode
1. ‘C-P’ Sleep mode:five minutes without any operation, the digital display automatically turns off, the program running as usual;
2. ‘O-d’ normal mode:digital display always open;
Press the ‘STOP’ button for two seconds and then release to switch ‘C-P’ and ‘O-d’ state, in which the current state of flashes and then return to the main screen.
Package Included
3 x DC 1 Channel Time Delay Relay Module
3 x Shell Case
Weight | 0.222 kg |
---|
Customers Also Viewed
3000W Power inverter DC 12V to AC 220V Boat Car inverter USB Charger Converter
$56.69InvertersAdd to cartSpecificationsName:Car power inverter 3000W.Input voltage:DC 10.5V~15V,Output frequency is:60HzSurge power:3000WContinous power:300WOutput waveform:Modified sine wavePackage Size:7.3′ x 4.0′ x 5.8′Weight:0.6 kgAdavantage[3000W Power inverter] Car power inverter with 2 USB ports and AC outlet. surge power:3000W.[ Fast Charging Dual USB ports] can charge most phones and tablets simultaneously (Max 4.1A), while AC outlets great for laptop, CPAP machine, …
3000W Power inverter DC 12V to AC 220V Boat Car inverter USB Charger ConverterRead More
5pcs 2*13 USB Mini Voice Control Music Audio Spectrum Flash Volume Level Red LED Display Module
$37.14Display ScreenAdd to cartFeatures1. Comes with a microphone, do not take the audio cable.2. Power 5V (USB interface power supply)3. High brightness:all using authentic Taiwan billion light bright LED4. Using a single-chip drive, the frequency spectrum is better, not bright and clear high brightness.5. Sensitivity to sound, 10 adjustable.Size:39.5mmx15mmx10mmColor:RedPackage Included5 x 2*13 USB Mini Audio LED Display Module
AC Volt Meterr Ammeter Din Rail LED Multifunction Digital Meter
$66.81Switch AccessoriesAdd to cartDescriptionThis din rail LED AC multifunctional digital meter can display voltage,current,active power,reactive power andpower factor simultaneously.It is suitable for electric power systems, home, power distribution box, electricalmachinery and equipment monitoring the power grid and power parameters.SpecificationsMeasuring Voltage Range:AC 80-300VMearuring Current Resolution Ratio:0-100.0A>10A:0.1AActive Power:0-30000WReacitive Power:0-30000VAPower Factor:COSφ=1.000-0.000Measuring Speed:2 times/secondAccuracy:1%,±2 wordsDin Rail Size:35mm din railSize:54*80*64 mmFeatures1. Din rail …
AC Volt Meterr Ammeter Din Rail LED Multifunction Digital MeterRead More
CJMCU-35 LPS35HW Pressure Sensor Waterproof and Moisture-proof Height Sensor Module Absolute Barometer
$28.42Sensor & Detector ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.IntroductionLPS35HW is an ultra-compact piezoresistive, digital pressure sensor with output barometer.The device includes a sensing element and an IC interface. The sensing element that communicates through IIC or SPI can detect absolute …
Low Pass Filter Bass Subwoofer Preamp Amplifier Board Single Power DC 9-32V Preamplifier with Bass Volume Adjustment
$16.97Amplifier BoardAdd to cartDescriptionThe so-called low-pass filter to filter out the human voice board is more than treble part, retain the low frequency part is amplified to improve the bass reproduction efforts, people will not hear the sound of musical instruments and high-frequency sound during playback. FeaturesPower supply voltage:DC 9V-32V single power supplyDual channel input, subwoofer output, then …
10pcs 0038 1738 integrated Universal Receiver infrared Receiver Tube module
$4.36Electronic Accessories & SuppliesAdd to cartDescriptionReceiving range:12-13 metersVoltage range:2.7V-5.5VPin pitch 2.5MMFront Side:First Foot is OUT, Second Foot is GND, Third Foot is VCC.Package included10 x 0038 1738 Integrated Universal Receiver Infrared Receiver Tube
Reviews
There are no reviews yet.