DC 24V Multifunctional Relay Module with LED Display Delay /Self Lock / Cycle / Timing
$13.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. New upgraded version with up to 20 functions preset to meet more application needs;
2. Optimize the software and hardware design, enhance the anti-interference ability of the module, and the system is more stable and reliable;
3. With power supply anti-reverse function, it will not damage the module due to wrong power supply;
4. The timing can be adjusted between 0.1 seconds and 270 hours;
5. All setting parameters can be saved, and the setting contents will not be lost when power is off.
Electrical Parameter
Working voltage:DC 24V
Working current:05V module is less than 90mA (less than 15mA when the relay is not operating, the display is less than 3mA)
Working temperature:-30 ° C – 70 ° C (limit range -40 ° C – 80 ° C)
Relay normally open port maximum load capacity:DC 0-30V/10A, AC 0-250V/10A
Relay normally closed port maximum load capacity:DC 0-28V/10A, AC 0-125V/10A
Dimensions:66mm x 41mm x 20mm (length x width x height)
Module Interface
Module voltage / signal input:3-wire interface, all interfaces have terminal blocks for user convenience
1, DC+:DC power supply positive
2, DC-:DC power supply negative
3, X1:input signal detection interface
Relay load output:3-wire interface, all terminals have terminal blocks
1, NO:relay normally open interface, the relay is suspended before the suction, after the suction is shorted with COM
2, COM:relay common interface
3, NC:relay normally closed interface, shorted to COM before the relay is sucked, suspended after suction
Module Function
Users can choose the required functions and parameters by simple operation. All parameters can be saved after power-off. The time parameter setting can be adjusted by 0.1 second minimum, and the precision is better than 0.01 second.
For example, if the user selects the function 16, the system will save the user settings, and the function 16 will be automatically run each time the phone is turned on until the user changes the settings again.
Function 1:Power-on delay pull-in:After the delay of T1 from the start of power-on, the relay is closed, T1 is adjustable between 0.1 seconds and 270 hours, and a high-level pulse signal is given to the X1 interface at any time. Reset and resume running;
Function 2:Power-on delay off:When the power is on, the relay is closed. After the T1 time is closed, the relay is disconnected. T1 is adjustable between 0.1 seconds and 270 hours. A high-level pulse signal is given to the X1 interface at any time. , this function resets and restarts;
Function 3:Timing pull-in and then disconnect:the relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 4:Timing disconnection and re-sucking:the relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 5:Infinite loop mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the above state is repeated; T1 and T2 are between 0.1 second and 270 hours. Adjustable between each time, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 6:Infinite loop mode 2:The relay immediately picks up when power is on, the relay turns off after the pull-in time T1 arrives; the relay picks up after the break time T2 arrives, and then repeats the above state, T1 and T2 are in 0.1 second-270 Adjustable between hours, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts operation;
Function 7:Limited cycle mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the NX times are repeated, T1 and T2 are at 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 8:Limited cycle mode 2:The relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and then the NX times are repeated, T1 and T2 are in 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 9:Self-locking relay mode:A high-level pulse signal is sent to the relay X1 interface, the relay is pulled in, and a high-level pulse signal relay is turned off.
Function 10:Level trigger relay mode (including delay off function):When the power is turned on, the relay is disconnected, and a high level signal is sent to the X1 interface. The relay immediately pulls in. After the X1 port signal disappears, the relay still pulls in. After the pull-in time T1 arrives, the relay is turned off, and T1 is adjustable between 0 seconds and 270 hours.
Note:In this function, if T1 is set to 0 seconds, it will become:X1 port has a high level signal relay to pull in, and if there is no signal, it will be disconnected immediately.
Function 11:Timing pull-up after triggering:the relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface, delaying the T1 time relay to pull in, T1 is adjustable between 0.1 seconds and 270 hours, repeating to the X1 interface a high-level pulse signal, repeating the above functions more than once;
Function 12:After the trigger, the timing is disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. The relay is closed, and the T1 time relay is disconnected. The T1 is adjustable between 0.1 seconds and 270 hours. Repeat a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 13:After the trigger, the timing is closed and then disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, T1 And T2 can be adjusted between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions;
Function 14:After the trigger, the timing is disconnected and re-closed:the relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the disconnection time T2 arrives. Pull-in, T1 and T2 are adjustable between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 15:Infinite loop mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected and then repeated. The above actions, T1 and T2 are adjustable between 0.1 second and 270 hours, and a high-level pulse signal is repeatedly given to the X1 interface, and the above functions can be restarted;
Function 16:Infinite loop mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives. Then repeat the above actions, delay T1 and T2 to be adjustable between 0.1 seconds and 270 hours, repeat a high-level pulse signal to the X1 interface, and restart the above functions;
Function 17:Limited cycle timing mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, and then the relay is turned off. Repeat NX times or more, T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, and the cycle number NX is adjustable between 1-9999 times. Repeating a high-level pulse signal to the X1 interface can restart the above functions;
Function 18:Limited cycle timing mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is immediately pulled in, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the break time T2 arrives. Pull in, then repeat NX times or more, at this time T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, the number of cycles NX is adjustable between 1-9999 times, repeating a high-level pulse signal to the X1 interface. , you can restart the above functions;
Function 19:Conditional cycle mode 1:The relay is disconnected at power-on, giving a high-level signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, as long as the X1 port is high. Does not disappear, the module will repeat the above action, T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Function 20:Conditional loop mode 2:The relay is disconnected at power-on, a high level signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives, as long as X1 The high level of the port does not disappear, the module will repeat the above action, the extension T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Package Included
1 x Multifunctional Relay Module
Weight | 0.027 kg |
---|
Customers Also Viewed
40x20x20cm Acrylic Display Box Clear Perspex Plastic Dustproof Base Transparent Case
$69.97DIY Electronic KitsAdd to cartFeatures– Made of acrylic material, clear and lightweight.– Simply design, very easy to install.– It is an wonderful display case, keep your collection figures tidy and clean.SpecificationsMaterial:AcrylicColor:TransparentSize:(L x W x H )21cm x 21cm x 41cm (8.3’x8.3’x16.1′)NOTEYou need to assemble the sheet into a box.Notice1. Please allow 1-3cm error due to manual measurement. Please make …
40x20x20cm Acrylic Display Box Clear Perspex Plastic Dustproof Base Transparent CaseRead More
3Pcs 1*40P Curved Needle Tin Plated Single Curved Needle 2.54MM Pin Connector
$2.15Module ComponentsAdd to cartSpecificationRoted Current:3.0AMPContocl Resistonce:20m┯ MaxWithstand Voltage:1000V AC/DCInsulation Resistance1000m┯ MinOperation Temperature:-40→ ~+105→Contact Material:BrassContact Plating:Tin over NiInsulator Material:Polyester(UL94V-0)Standard:PA6TMax.Processing Temp:230→ for 30-60 seconds(260→ for 10 seconds)Package included3 x 1*40P Single Curved Needle
3Pcs 315MHz XD-FST XD-RF-5V Wireless Transmitter Receiver Module Board Not Super-heterodyne
$6.80Smart ModuleAdd to cartTransmitter ModuleSpecificationWorking voltage:3V ~ 12VWorking current:20mA ~ 28mAStandby current:0mAWorking frequency:315MHzTransmitter distance:>500m (sensitivity can be above -103dBm if in wide field)Output power:16dBm (40mW)Transmitter rateModulation mode:OOK (AM)Working temperature:-10°C ~ +70°CSize:19 x 19 x 8mmFeatureStable performanceWider range of working voltagePinsPIN1 ATAD:data inputPIN2 VCC:power +PIN3 GND:power –ApplicationWireless calling system, burglar alarm, wireless data transmission, automated data acquisition systemReceiver Module …
3Pcs 315MHz XD-FST XD-RF-5V Wireless Transmitter Receiver Module Board Not Super-heterodyneRead More
6-30V 1 Channel Relay Module Switch Trigger Time Delay Circuit Timer Cycle Adjustable
$13.11Relay ModuleAdd to cartFeatures1. Trigger Signal Source:High Level Trigger (3.0 V-24 V), signal ground and system ground are not common, which can increase anti-interference abilitsystem (short circuit can also connect with a ground common)2. Output Capacity:can control no more than DC 30V 5A AC or 220 V devices 5A3. Optocoupler Isolation:improve the anti-interference ability, after the parameter setting, …
6-30V 1 Channel Relay Module Switch Trigger Time Delay Circuit Timer Cycle AdjustableRead More
3Pcs Wemos Motor Shield for WeMos D1 Mini I2C Dual Motor Driver TB6612FNGV1.0.0
$21.01Driver ModuleAdd to cartFeaturesI2C interfacePower supply voltage:VM=15V maxOutput current:Iout=1.2A(average) / 3.2A (peak)Standby control to save powerCW/CCW/short brake/stop motor control modesPins DescriptionVM:Motor power supply + (Max 15Vdc)GND:Motor power supply –A1 A2:Motor AB1 B2:Motor BS:Standby control port (in IO mode)More detail:Click Here!Package included3 x Motor Shield For WeMos D1 Mini
10Pcs TCRT5000 E2A3 1-Channel Smart Car infrared Tracking Sensor Detection PIR Sensor Module
$12.31Sensor & Detector ModuleAdd to cartProduct Usage1, the meter pulse data sampling2, fax machine shredder paper detection3, obstacle detection4, black and white line detectionProduct parametersInfrared reflection sensor:TCRT5000Detection reflection distance:1mm~25mmWorking voltage:5VOutput form:digital signal (0 and 1)Installation:with fixing bolt holesSmall board PCB size:3.5cm x 1cmSingle weight:4.5gFeaturesThe infrared emitting diode of the TCRT5000 sensor continuously emits infrared rays. When the emitted infrared rays …
5pcs DIY Technology invention Single-wing Wind Car Assembly Model DIY Car Kit
$28.96DIY Electronic KitsAdd to cartSpecificationsMaterial:WoodSize:approx. 12*7.6*12cmMulti-function:NoPower supply:2x AA Battery(not included)Foreign trade:YesDIY:Do it yourself according finished product painting in the package.ApplicationsInterest-building, parent-child communication, emotion, sensory,intellectual development, hands-on brain, hearing, interactive toys, grasping,hand-eye coordination, other abilitiesNote1.Please allow 1-3cm errors due to manual measurement.2.Due to the difference between different monitors, the pictures may not reflect the actual color of the item.Package Included5 …
5pcs DIY Technology invention Single-wing Wind Car Assembly Model DIY Car KitRead More
Reviews
There are no reviews yet.