DC 24V Multifunctional Relay Module with LED Display Delay /Self Lock / Cycle / Timing
$13.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. New upgraded version with up to 20 functions preset to meet more application needs;
2. Optimize the software and hardware design, enhance the anti-interference ability of the module, and the system is more stable and reliable;
3. With power supply anti-reverse function, it will not damage the module due to wrong power supply;
4. The timing can be adjusted between 0.1 seconds and 270 hours;
5. All setting parameters can be saved, and the setting contents will not be lost when power is off.
Electrical Parameter
Working voltage:DC 24V
Working current:05V module is less than 90mA (less than 15mA when the relay is not operating, the display is less than 3mA)
Working temperature:-30 ° C – 70 ° C (limit range -40 ° C – 80 ° C)
Relay normally open port maximum load capacity:DC 0-30V/10A, AC 0-250V/10A
Relay normally closed port maximum load capacity:DC 0-28V/10A, AC 0-125V/10A
Dimensions:66mm x 41mm x 20mm (length x width x height)
Module Interface
Module voltage / signal input:3-wire interface, all interfaces have terminal blocks for user convenience
1, DC+:DC power supply positive
2, DC-:DC power supply negative
3, X1:input signal detection interface
Relay load output:3-wire interface, all terminals have terminal blocks
1, NO:relay normally open interface, the relay is suspended before the suction, after the suction is shorted with COM
2, COM:relay common interface
3, NC:relay normally closed interface, shorted to COM before the relay is sucked, suspended after suction
Module Function
Users can choose the required functions and parameters by simple operation. All parameters can be saved after power-off. The time parameter setting can be adjusted by 0.1 second minimum, and the precision is better than 0.01 second.
For example, if the user selects the function 16, the system will save the user settings, and the function 16 will be automatically run each time the phone is turned on until the user changes the settings again.
Function 1:Power-on delay pull-in:After the delay of T1 from the start of power-on, the relay is closed, T1 is adjustable between 0.1 seconds and 270 hours, and a high-level pulse signal is given to the X1 interface at any time. Reset and resume running;
Function 2:Power-on delay off:When the power is on, the relay is closed. After the T1 time is closed, the relay is disconnected. T1 is adjustable between 0.1 seconds and 270 hours. A high-level pulse signal is given to the X1 interface at any time. , this function resets and restarts;
Function 3:Timing pull-in and then disconnect:the relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 4:Timing disconnection and re-sucking:the relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 5:Infinite loop mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the above state is repeated; T1 and T2 are between 0.1 second and 270 hours. Adjustable between each time, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 6:Infinite loop mode 2:The relay immediately picks up when power is on, the relay turns off after the pull-in time T1 arrives; the relay picks up after the break time T2 arrives, and then repeats the above state, T1 and T2 are in 0.1 second-270 Adjustable between hours, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts operation;
Function 7:Limited cycle mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the NX times are repeated, T1 and T2 are at 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 8:Limited cycle mode 2:The relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and then the NX times are repeated, T1 and T2 are in 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 9:Self-locking relay mode:A high-level pulse signal is sent to the relay X1 interface, the relay is pulled in, and a high-level pulse signal relay is turned off.
Function 10:Level trigger relay mode (including delay off function):When the power is turned on, the relay is disconnected, and a high level signal is sent to the X1 interface. The relay immediately pulls in. After the X1 port signal disappears, the relay still pulls in. After the pull-in time T1 arrives, the relay is turned off, and T1 is adjustable between 0 seconds and 270 hours.
Note:In this function, if T1 is set to 0 seconds, it will become:X1 port has a high level signal relay to pull in, and if there is no signal, it will be disconnected immediately.
Function 11:Timing pull-up after triggering:the relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface, delaying the T1 time relay to pull in, T1 is adjustable between 0.1 seconds and 270 hours, repeating to the X1 interface a high-level pulse signal, repeating the above functions more than once;
Function 12:After the trigger, the timing is disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. The relay is closed, and the T1 time relay is disconnected. The T1 is adjustable between 0.1 seconds and 270 hours. Repeat a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 13:After the trigger, the timing is closed and then disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, T1 And T2 can be adjusted between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions;
Function 14:After the trigger, the timing is disconnected and re-closed:the relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the disconnection time T2 arrives. Pull-in, T1 and T2 are adjustable between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 15:Infinite loop mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected and then repeated. The above actions, T1 and T2 are adjustable between 0.1 second and 270 hours, and a high-level pulse signal is repeatedly given to the X1 interface, and the above functions can be restarted;
Function 16:Infinite loop mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives. Then repeat the above actions, delay T1 and T2 to be adjustable between 0.1 seconds and 270 hours, repeat a high-level pulse signal to the X1 interface, and restart the above functions;
Function 17:Limited cycle timing mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, and then the relay is turned off. Repeat NX times or more, T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, and the cycle number NX is adjustable between 1-9999 times. Repeating a high-level pulse signal to the X1 interface can restart the above functions;
Function 18:Limited cycle timing mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is immediately pulled in, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the break time T2 arrives. Pull in, then repeat NX times or more, at this time T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, the number of cycles NX is adjustable between 1-9999 times, repeating a high-level pulse signal to the X1 interface. , you can restart the above functions;
Function 19:Conditional cycle mode 1:The relay is disconnected at power-on, giving a high-level signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, as long as the X1 port is high. Does not disappear, the module will repeat the above action, T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Function 20:Conditional loop mode 2:The relay is disconnected at power-on, a high level signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives, as long as X1 The high level of the port does not disappear, the module will repeat the above action, the extension T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Package Included
1 x Multifunctional Relay Module
Weight | 0.027 kg |
---|
Customers Also Viewed
3Pcs RobotDyn RTC DS1307 Real Time Clock Battery Shield with Pin Headers Set
$18.67Expansion Board & ShieldAdd to cartPINOUT:http://img.staticbg.com/file/products/20171226001032PINOUT-RTCDS1307.pdfSchematic:http://img.staticbg.com/file/products/20171226001140Schematic-RTCDS1307.pdfFeatureType:Logic ICsPackage includes3 x RTC DS1307 (real time clock) + battery3 x Wemos D1 mini shield6 x Male Pin Header 8pins6 x Female Pin Header -BLACK 8pins6 x Stackable Header – BLACK 8pins
110V Electric Pet Heating Mat Winter Heated Blanket 2 Speeds Waterproof Cat Dog Heater Pads Bed Bite Resistant
$40.49Laboratory Heating EquipmentsAdd to cartSpecificationsType:CushionRated voltage:110V 50HzRated power:20WPlug:US Plug(We will provide adapter according to delivery country)Material:Polyester + cottonSize:45cmx45cm/17.7inchx17.7inchFeature-Soft cotton texture and vivid prints attract pets’ attention.-Two-speed temperature adjustment (high temperature 50 °C,low temperature 30 °C),can be adjust the temperature level.-The heating rate is fast, warm and comfortable,overheat protection.-Scratch and bite resistant,not easily damaged,thick and durable.-Keep warmer in winter,safe and …
Geekcreit UNO+WiFi R3 ATmega328P+ESP8266 32Mb Memory USB-TTL CH340G Module
$19.67Motherboard & Development BoardAdd to cartDescriptionFull integration on one board:Uno R3 ATmega 328 and WiFi ESP8266 with memory 32Mb (MegaByte). All of the modules can work together or each separately. And everyone has their own pinout headers.The convenient solution for the development of new projects requiring Uno and WiFi.Via USB you can update sketches and firmvare for ATmega328 and for …
Geekcreit UNO+WiFi R3 ATmega328P+ESP8266 32Mb Memory USB-TTL CH340G ModuleRead More
3pcs CA-255 10-42inch LED TV Constant Current Board Universal inverte LED TV Backlight Driver Board
$16.47Driver ModuleAdd to cartSpecificationInput Vol:10.8-28VOutput Vol:15-88vsize:8.5×4.5CM1.VCC:power supply and voltage positive, circuit voltage (The voltage is usually 12V or 24V)2.ON / OFF, ON, EN, ON_BL etc:switch foot, foot switch signal (The voltage range is between 2.5V-5V)3. PWM, PDIM, VDAJ, BL-PWM et al:brightness adjustable feet (Dimming have two modes, one is in digital mode -PWM, one is analog dimming -DC4.The …
30pcs A4988 Driver Module Stepper Motor Driver Board with Heatsink
$54.70Motor PWM Speed ControllerAdd to cartFeature1. It is suitable for driving stepper motors of 8V~35V 2A or less2. Only simple step and direction control interface3. Five different stepping modes:full, half, 1/4, 1/8 and 1/164. The adjustable potentiometer can adjust the maximum current output to obtain a higher step rate5. Automatic current decay mode detection/selection6. Overheat shutdown circuit, under-voltage lockout, cross-current …
30pcs A4988 Driver Module Stepper Motor Driver Board with HeatsinkRead More
10pcs 801S Vibration Shock Sensor Control Module Sensitivity Adjustable Board
$79.70Sensor & Detector ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.Features1. having a signal output instruction;2. with a TTL level signal, and the analog output signal;3. the output valid signal is high, the light goes out;4. the sensitivity is adjustable (fine-tuning);5. wide …
10pcs 801S Vibration Shock Sensor Control Module Sensitivity Adjustable BoardRead More
5pcs W3231 incubator Temperature Controller thermometer Cool/Heat Digital Dual Display with NTC Sensor DC12V
$41.22Sensor & Detector ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.DescriptionTemperature Control:-55C~120C/-67F~ 248FTemperature Control Accuracy:0.1 C / 0.1 FDisplay Color:Red + BlueWorking Power Supply:DC12VTemperature Sensor:1M NTC 10K Product Size:79.2mm≠41.9mm≠26.3mmHole Size:72.1mm≠39.2mmOperation and Display PanelWarning codeCodeReason for errorSolutionHHHTemperature exceeds alarm temperatureThe temperature drops below …
CO2 System Pro Tube Air Valve Guage Bottle Cap Kit for DIY Aquarium Planted Tank
$68.84ConnectorsAdd to cartTechnical SpecificationsColor:WhiteMaterial:ABS and MetalTube Inner Size:4mmFeatures and Benefits Easy to set up CO2 system is designed for low cost planted tank use. 2 air-pipe locks on the bottle cap, prevent the air-pipe get loose ABS bottle caps, good pressure resistance, NO deformation Specialized pressure gauge, build-in automatic safe valve,Keeps pressure in the safe level, never …
CO2 System Pro Tube Air Valve Guage Bottle Cap Kit for DIY Aquarium Planted TankRead More
Reviews
There are no reviews yet.