3pcs HC-SR501 Adjustable infrared IR Pyroelectric PIR Module Motion Sensor Human Body induction Detector
$8.65
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. Automatic induction:When someone enters its induction limits, enter the high level, people leave the sensor range is automatically delayed off high. Output low.
2. photosensitive control (optional):the module reserved for location, can be set to photosensitive control, strong light during the day or not induction. Photosensitive control is optional, the factory did not install the photosensitive resistor. If necessary, please buy a separate photosensitive resistor to install.
3. Two trigger modes:L is not repeatable, H is repeatable. Can be jumper selected, the default is H.
A. non-repeatable trigger mode:the induction output high, the delay time is over, the output will automatically change from high to low.
B. Repeated trigger mode:that is, after sensing the output high, in the delay time period, if the human body in its sensing limits of activities, its output will remain high until the delay after the person will leave the high The level changes to low level (the sensing module automatically delays a delay time after every activity of the human body, and takes the time of the last activity as the starting point of the delay time).
4. Induction blocking time (default setting:3-4 seconds):After each sensing output (high level goes low), the sensing module can be followed by a blocking time, during which it is sensed The device does not receive any sense signals. This function can be used to achieve the interval between the sensing output time and the blocking time. It can be applied to the interval detection products. At the same time, this function can effectively suppress all kinds of interference in the process of load switching.
5. Wide operating voltage:the default operating voltage DC5V to 20V.
6. Micro-power:Quiescent current 65 microamps, especially for dry battery-powered electrical products.
7. Output high-level signal:can be easily with various types of circuits to achieve docking.
Instructions for use
1. Induction module power about one minute after the initialization time, at this time the module will output 0-3 times a minute, a minute into the standby state.
2. Light and other interference should be avoided Directly close the surface of the lens module, so as not to introduce interference with the signal to produce malfunction; use of the environment as far as possible to avoid
Free flow of wind, the wind will cause interference to the sensor.
3. Sensor module with dual-element probe, the probe window is rectangular, dual element (A yuan B yuan) in the longer direction at both ends, when the body from left to right
Or from right to left through the infrared spectrum to the dual time, distance difference, the greater the difference, the more sensitive induction, when the body from the front to the probe
Head or from top to bottom or from bottom to top direction, the dual element can not detect infrared spectral distance changes, no difference, so the sensor insensitive or does not work; so the sensor should be installed so that the direction of the probe dual And the direction of human activity as much as possible parallel to ensure that the body has been through
Probe dual-element induction. In order to increase the sensing angle limits, this module uses a circular lens, also makes the probe four sides are sensitive, but the left and right sides are still
However, compared with the upper and lower direction of the two induction limits, sensitivity, installation must still try to according to the above requirements.
Use should pay attention to the following points
1. The DC voltage must meet our requirements, too high and too low will affect the performance of the module, but also requires the power supply must be a good regulator filter, such as computer USB power, mobile phone charger power supply, the old 9V stacked battery Are unable to meet the module work requirements, it is recommended that customers use the power transformer and the regulator through the three-terminal voltage regulator and then through the 220UF and 0.1UF capacitor filter power supply.
2. Although the human body is not in front of the module, but the human body from the module is too close to the module can also be caused by the sensor output, as well as debugging the human body do not touch the circuit part will also affect the module work , A more scientific approach is to output a LED or a multimeter, the module covered with a newspaper, when someone leaves room, wait 2 minutes and see if the module still has output.
3. The module does not take the load to work properly, connected to the load after the work of chaos, one reason is because the power capacity is very small load power consumption, load caused by voltage fluctuations caused by the module malfunction, the other reason is the load The power will have interference in the work, such as relays or electromagnets and another inductive load will produce a reverse electromotive force, 315M emission plate will have electromagnetic radiation and other work will affect the module. The solution is as follows:A, the power part of the inductor filter. B, using the load and the module using different voltage methods, such as:load using 24V operating voltage, the module uses 12V operating voltage, during which the use of three-terminal regulator isolation. C:Use a larger capacity power supply.
4. The human body sensor module can only work indoors and the work environment should avoid the sun, a strong direct light exposure, if the work environment has a strong RF interference, you can use shielding measures. In case of strong air interference, close the doors and windows or prevent convection. The induction area to avoid facing heating appliances and objects as well as easy to wind debris and clothing.
5. The human body sensor module is recommended to install in a sealed box, otherwise, there may have been the output signal.
6. If the body sensor module detection angle is less than 90 degrees, you can use opaque adhesive tape to cut off the lens or cut lens to achieve.
7. The human body sensor module with dual-element probe, the body’s hands and feet and head movement direction and the sensitivity of the sensor are closely linked, and the infrared module determines the characteristics of the sensor can not accurately control the distance.
8. The module of the probe (PIR) can be mounted on the other side of the circuit board. The probe can also be extended with a two-core shielded cable, the length should be less than 20 cm as well.
Package includes
3 x HC-SR501 Motion Sensor
Weight | 0.027 kg |
---|
Customers Also Viewed
3Pcs 0.96 inch 4Pin White IIC I2C OLED Display Module 12864 LED
$38.88Display ScreenAdd to cartFeatureOLED Driver IC:SSD1306Resolution:128 x 64Visual Angle:>160°Input Voltage:3.3V ~ 6VCompatible I/O Level:3.3V, 5VMini Size:2.7 x 2.8cmOnly Need 2 I/O Port to ControlFull Compatible , 51NoteIf you decide to buy OLED display, you must confirm that you can make it work by yourself, we’ll haven’t any technology support. Thanks for your understanding and support.Package included3 x 0.96 …
3Pcs 0.96 inch 4Pin White IIC I2C OLED Display Module 12864 LEDRead More
Micro:Bit bluetooth 4.0 Low Energy Open Development Board for Programming
$60.06Raspberry Pi & Orange PiAdd to cartOverviewThe micro:bit is an open development board that allows you to run code on it and have access to all of the hardware.You can use your micro:bit for all sorts of cool creations, from robots to musical instruments – the possibilities are endless.This little device has an awful lot of features, like 25 red LED …
Micro:Bit bluetooth 4.0 Low Energy Open Development Board for ProgrammingRead More
500mL 24/40 Glass Filtering Flask Lab Filtration Conical Flask Bottle Laboratory Glassware
$58.71Glassware KitAdd to cartDescription– Flasks are glass or plastic containers for storing or collecting chemical samples or solutions in scientific laboratories.– It shaped like a cone with a wide, flat base that narrows to a neck opening, which can be closed with a stopper or cap.SpecificationMaterial:Borosilicate GlassCapacity:500mLFlask Style:Filtering (vacuum)Feature– The neck is 24/40 Ground Joint.Package Included1 x Glass …
500mL 24/40 Glass Filtering Flask Lab Filtration Conical Flask Bottle Laboratory GlasswareRead More
AC 100W 40KHZ Ultrasonic Cleaning Power Driver Board with 50W 40K Transducer 220V
$98.40Driver ModuleAdd to cartSpecificationsPower:220V 100WPendulum:50W 40KHZApplies to:Low-power ultrasonic cleaning machine, household cleaning machine, ultrasonic generator built machine.Features1. The ultrasonic generator can monitor the power system frequency ultrasound power.2. According to different requirements of users, real-time adjustment of various parameters, the power, amplitude, and running time.Circuit board and vibration head (ceramic transducer) Wiring instructions1. The board can not no-load …
AC 100W 40KHZ Ultrasonic Cleaning Power Driver Board with 50W 40K Transducer 220VRead More
5pcs 3S 18650 4A 11.1V BMS Li-ion Battery Protection Board 18650 Battery Charging Module Charger Electronic DIY
$19.48Battery Protection ModuleAdd to cartSpecificationsCharging Voltage:12.6V-13VOvercharge Voltage Range:4.25V-4.35V ± 0.05VOverpressure Voltage Range:2.3V-3.0V ± 0.05VUpper Limit Operating Current:3A-4AUpper Limit Instantaneous Current:9A-10AQuiescent Current:less than 30uAInternal Resistance:less than 100mohmEffective Life:more than 30,000 hoursOperating Temperature:-40- +50 degreesStorage Conditions:-40- +80 degreesSize:53 * 16 * 3mmShort Circuit Protection:protection, delay self-recovery ApplicationsThe power range is suitable for the following products:massager battery pack, LED light standby power …
3pcs infrared Light IR Camera Control Board for Surveillance Camera Night Vision CCTV Accessories
$10.52Driver ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.SpecificationsCurrent:700mAVoltage input:12V DCVoltage output:1.7-12V DCSize:38MM * 38MMPotential:good night vision effect; rigorous design, stable performance and strong anti-interference.Use:Suitable for all kinds of infrared lamp board drive, suitable for 1-6 infrared lampFunction:It can be …
Reviews
There are no reviews yet.