3pcs 24V XH-W3002 Micro Digital thermostat High Precision Temperature Control Switch Heating and Cooling Accuracy 0.1
$34.33
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Feature
Product Name:Microcomputer Temperature Controller
Product model:XH-W3002
Temperature range:-50~110°C
Temperature control range:-50~110°C
Temperature measurement accuracy:+-0.2 °C
Temperature control accuracy:+-0.1 °C
Temperature probe:NTC10K (B3950) 1 meter waterproof probe
Supply voltage:DC12V/DC24V/AC220V
Output power:DC24V:240W
Output type:direct output
Appearance size:60 x 45 x 31mm
Opening size:73mm (aperture 4mm)
Package includes
3 x Microcomputer Temperature Controller
Wiring
Key Description
Up key:Short press to display the starting temperature, long press to set the starting temperature.
Down button:short press to display the stop temperature, long press to set the stop temperature.
Shutdown button:Press to turn off the thermostat, and then press to turn on the thermostat.
Code:Code description:Setting range:Factory setting
P0:Starting temperature:-50~110°C:25
P1:Stop temperature:-50~110°C:40
P2:Temperature correction:-10~10°C:0°C
P3:Delayed start:0-10 minutes:0
P0. Set the startup temperature
Press the Setup button to enter the internal menu. The default display is P0. Press the Setup button again and set the desired startup temperature by pressing the up and down buttons.
P1. Set the stop temperature
Press the setup button to enter the internal menu, the display is P0, switch to P1 by the up and down keys, press the setup button again, and set the required stop temperature by the up and down buttons.
P2. Set the temperature correction
In the same way, enter the internal menu, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by pressing the up and down buttons. (Note:In the setting, if the detected temperature value is 0.5 °C larger than the actual temperature value, then the calibration temperature to be set is -0.5 ° C. If the detected value is 1 ° C smaller than the actual temperature value, the set calibration temperature is required. It is 1 ° C. Detection temperature + correction temperature = actual temperature.)
P3. Set the delay start
In the same way, enter the internal menu, switch to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time by the up and down buttons, the unit is minute. (Note:Delay start is generally used for compressor refrigeration. If it is used in refrigerator freezer, this value needs to be set. According to compressor back pressure, the general setting is 3-6 minutes, if you are not using it for control or doesn’t need delay function, skip directly.
Instructions
Start temperature
Start temperature > stop temperature = cooling mode (output is connected to the cooling unit)
1. Connect the power supply and heating or cooling equipment according to the wiring diagram above (note the positive and negative poles)
2. Press and hold the up key to set the starting temperature. When the screen number flashes, press the up and down keys to set the starting temperature you want. After setting, wait for 5 seconds to brake the system.
3. Press and hold the key to set the stop temperature. When the screen number flashes, press the up and down keys to set the desired stop temperature. After setting, wait for 5 seconds to automatically save the data.
4. Restore the factory:Colleagues press and hold the up and down keys for 5 seconds, when the screen displays 888, the factory is restored.
5. Press the power off button to turn off the thermostat and press to turn on the thermostat.
Tips
888:In the case of power-on, press and hold the up and down keys for about 3 seconds, the digital tube displays 888, and automatically jumps to the detection temperature, that is, the factory settings are restored successfully.
LLL:Describe the sensor is open circuit, repair the sensor, or replace the sensor
HHH:The sensor is short circuit.
Weight | 0.165 kg |
---|
Customers Also Viewed
R103C 6GHz 5.8G Broadband Directional Antenna High Gain ads-b UAV Image Transmission Antenna
$30.90RF amplifierAdd to cartDescriptionThis directional antenna is suitable for directional radio signal transmission and reception signal source reconnaissance lateral, broadband signal testing, etc.The antenna covers the common frequencies of mobile phone communication, UWB positioning module and Wifi and other radio frequency unitsFrequency range:850MHz-6GHzDimensions:22*15CMPolarization method:linear polarizationRated gain:7dbiReturn loss:10DBPower:5WWeight:110gPackage included1 x Broadband Directional Antenna
3Pcs HY-SRF05 Ultrasonic Distance Sensor Module Measuring Sensor Module
$13.93Sensor & Detector ModuleAdd to cart3Pcs HY-SRF05 Ultrasonic Distance Sensor Module Measuring Sensor ModuleDescriptionThis module performance is stable, measure the distance accurately. Module precision, blind spots (2cm) super close.SpecificationInput voltage:5V DCQuiescent currentOutput level(high):5VOutput level(low):0VInduction angleDetection distance:2cm – 450cmAccuracy:up to 0.3cmBlind spots:2cmPackage included3 x HY-SRF05 ultrasonic distance sensor module
AC Contactor AC220V Coil 32A 3-Phase 1NO 50/60Hz Motor Starter Relay LC1 D1810
$48.59RelaysAdd to cartDescriptionAC Contactor AC220V Coil 32A 3-Phase 1NO 50/60Hz Motor Starter Relay LC1 D1810Features1.High strength PC flame retardancy,AC220V copper coil.2.A contactor (motor starter) is a high capacity relay that has built-in auxiliary contact to work with momentary push buttons.3.It is versatile and is often used to control a motor or as a main power switch, sometimes …
AC Contactor AC220V Coil 32A 3-Phase 1NO 50/60Hz Motor Starter Relay LC1 D1810Read More
BESTEP 1 Channel 5V Low Level Solid State Relay Module with Fuse 250V2A for Auduino
$6.55Relay ModuleAdd to cartDescription1. 5V solid state relay 240V 2A, output with resistance fuse 240V 2A.2. Size:25*34*25 (length * width * height) Net weight:13g3. Input power:5V DC (160MA)4. Input control signal voltage:(0-1.5V state low level relay ON) (2.5-5V state high level relay OFF)5. The blue KF301 terminal is more convenient to connect to the control line.Module interfaceInput sectionDC+:Connect …
BESTEP 1 Channel 5V Low Level Solid State Relay Module with Fuse 250V2A for AuduinoRead More
ZL-7903A Multifunctional Automatic Temperature and Humidity incubator Controller XM-18 100-240V AC with with ZL-SHr05J Sensor
$107.15Test & Measuring ModuleAdd to cart>>>Manual:Click here to openFeatureZL-7903A is an industrial intelligent temperature and humidity controller. Optional external SSR to realize bigger heatingpower rate, and with optional temperature PID control. With touch button and big size LCD display, convenient to operate,easy to set up. Applicable for control of incubator, climate chamber, warehouse, and so on.Main Function1. Ventilation fan control2. …
Reviews
There are no reviews yet.