3pcs 24V XH-W1818 High Precision Microcomputer Temperature Controller Circular Digital Display Embedded thermostat
$42.69
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Feature
Product Name:High precision microcomputer temperature controller
Product model:XH-W1818
Temperature range:-50~110°C
Resolution:0.1 ° C
Temperature control range:-50~110°C
Temperature control accuracy:1 ° C
Temperature probe:NTC10K (B3950) L=1M
Supply voltage:DC24V
Applicable environment:-25~55°C Humidity 50%-85%
Output type:10A relay output
Appearance size:diameter 80mm
Opening size:diameter 61mm/3mm
How to use
1. Connect the power supply and load according to the instructions. Please do not overpressure and overload.
2. Setting mode, long press SET button for 5 seconds will display P0. Press SET button shortly to set H to heating mode and C to cooling mode (up and down button to switch)
3. Set the stop temperature, press the SET button once to flash the screen, and then press the up and down keys to set the desired stop temperature.
4. Press and hold the SET button for 5 seconds to display P0, press the up and down keys to switch to P1, then press the SET button to set the difference back (press the up and down keys to adjust). If the heating mode H needs to control the temperature between 36-38 degrees , then the stop temperature is set to 38 degrees and the back difference is set to 2 (the highest temperature minus the lowest temperature)
5. Indicator light. SET light is on to indicate that the parameter is being set; OUT indicator is flashing to indicate the start delay, and always on to indicate the output.
Setting function description
Press SET button for 5 seconds to enter internal parameter setting, up and down button to switch P0-P7
Code:Code description:Setting:Factory setting
P0:Operating mode:C/H:H
P1:Backlash setting:0.1-30:2
P2:Set upper limit:Max. 110 ° C:110°C
P3:Set lower limit:Min. -50 ° C:-50°C
P4:Temperature correction:-10~10°C:0°C
P5:Delayed start:0-10 minutes:0
P6:High temperature alarm:-50~110°C:110°C
P7:Data lock:OFF/ON:OFF
P0:Heating and cooling mode H/C
The low temperature start is the heating mode, set to H. For example:the actual temperature is 21 ° C, the temperature needs to be controlled between 36-38 ° C, we set P0 to H heating mode.
The high temperature start is the cooling mode, set to C. For example:the actual temperature is 38 °C, and the temperature needs to be controlled between 24-26 °C. We set P0 to C cooling mode.
P1:Hysteresis setting
In heating mode (H):The measured value starts the output heating to the set value when the set value – hysteresis.
For example, to control an indoor temperature between 36 and 38 ° C, the actual temperature is 20 ° C, heating equipment is required to heat room, P0 is set to H, the stop temperature is set to 38 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 38-36 = 2)
In cooling mode (C):When the measured value >= set value + hysteresis, the output cooling is started until the set value stops.
For example, to control an indoor temperature between 24 and 26 ° C, the actual temperature is 36 ° C, the cooling equipment is required to cool room, P0 is set to C, the stop temperature is set to 24 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 26-24 = 2)
P2:Limit the maximum set value (non-temperature control setting):up to 110 °C
For example, if P2 is set to 50 °C, then when you set the operation, the maximum temperature can only be set to 50 °C.
P3:Limit the min. set value (non-temperature control setting):min. -50 °C
For example, if P2 is set to 20 °C, then when you set the operation, the set min. temperature can only be 20 °C. Since P2 is set to 50 degrees and P3 is set to 20 degrees, then you set is only Can be adjusted between 20~50 degrees.
P4:Temperature correction
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
For example, the probe measurement temperature is 22.8 ° C, the standard temperature is 24.2 ° C, you need to increase the height by 1.4 degrees, set P4 = 1.4
For example, the probe measurement temperature is 26.31 ° C, the standard temperature is 23.5 ° C, it needs to be lowered by 2.8 degrees, and P4 = -2.8 can be set.
P5:Delay start time:0~10 minutes
When controlling the cooling of the compressor equipment, the delay time can be set as required. When the controller outputs, the equipment will not start immediately, and it needs to be started after the set delay time has elapsed. (Non-compressor control is set to 0)
P6:High temperature alarm
When the measured value is greater than the alarm value, the screen temperature flashes and the drip sound alarm, the output is forcibly turned off in the heating mode, and the output is not turned off in the cooling mode.
P7:Data lock function
Turn on the data lock, P7 is turned ON to save the current setting parameters without being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to enter P7 to turn OFF to turn off the data lock function.
Package includes
3 x High precision microcomputer temperature controller
Weight | 0.285 kg |
---|
Customers Also Viewed
10Pcs 5V-30V Wide Voltage Trigger Delay Timer Relay Conduction Relay Module Time Delay Switch
$48.30Relay ModuleAdd to cartDescriptionWide voltage 5V-30VTime can be adjusted via a potentiometer, meeting your most occasionsMicro USB 5.0V power supply with input, easy to use5–30V wide supply voltageExternal triggering and onboard buttons Two triggering methodsWith a relay pull-in indicatorInterference ability, under various interference will not malfunction relay for industrial control.Module features1. Working voltage:Wide voltage any voltage between 5-30V, …
110-220V 150W Foldable Electric Cloth Hanger Travel Heating Dryer Drying Rack
$46.56Switch AccessoriesAdd to cartFeatures1. 3-hours fast drying. Use clothes to form a wind hood, so that the hot air flow gathers inside the clothes and circulates to achieve the purpose of fast drying.2. Dual mode, cold and hot air switching. It will automatic conver to cold air after 3h hot air drying.3. PTC heating, low power consumption, safe …
110-220V 150W Foldable Electric Cloth Hanger Travel Heating Dryer Drying RackRead More
20Pcs 10ml Metal Needle Empty Plastic Bottle Shisha E Cig Liquid Dropper
$19.08Bottles & JarsAdd to cartDescription20Pcs 10ml Metal Needle Empty Plastic Bottle Shisha E Cig Liquid Dropper SpecificationsMaterial:PECapacity:10mlSize:20X77mm / 0.79X3.0 inchNeedle Size:Inner Diameter =0.8mm, Outer Diameter =1.2mm, Length=12mmQuantity:20 pcsFeatures1. 10ml empty plastic bottle with metal needle2. Metal needle design,durable and easy to use3. Ideal for storing E cig liquid,solvents, light oils , eye drops, saline, etc.Package included20 X 10ml Empty …
20Pcs 10ml Metal Needle Empty Plastic Bottle Shisha E Cig Liquid DropperRead More
3Pcs AC-DC 3.5W Isolated AC 110V / 220V To DC 3.3V 1A Switch Power Supply Converter Module
$19.93Power Supply ModuleAdd to cartDescriptionsThe power supply is isolated industrial grade built-in power module with temperature protection, overcurrent and short circuit full protection.FeaturesAC85 – 264V or DC110 – 370V wide voltage inputDC3.3V(+/ -1%) 1A isolated outputInput Current:0.5mA/115VAC 0.25mA/230VACInput surge current:10A (230VAC)Frequency range:47-63HzOperating Temperature:-30 – 70 →Relative humidity:20%- 90%Rated power:3.5WOutput efficiency:61%Module size:5.1*2.3*1.8cmPackage included3 x AC-DC 3.5W Isolated AC 110V / …
3Pcs AC-DC 3.5W Isolated AC 110V / 220V To DC 3.3V 1A Switch Power Supply Converter ModuleRead More
3Pcs XL4015 5A DC-DC Step Down Adjustable Power Supply Module Buck Converter
$16.35Boost & Buck ModuleAdd to cartSpecificationModule highlights:5A high power, high efficiency and low ripple with power indicatorModule Properties:non-isolated buck module (BUCK)Input voltage:8-36V (input please try not to exceed 38V)Output voltage:1.25-32V continuously adjustableOutput Current:0-5AOutput Power:75WOperating temperature:-40 to +85 degreesOperating frequency:180KHzConversion efficiency:up to 96%Load regulation:S (I) ≤0.8% (input 24V, output 12V, load varies from 1 ~ 4.5A measured)Voltage Regulation:S (u) ≤0.8% (output …
3Pcs XL4015 5A DC-DC Step Down Adjustable Power Supply Module Buck ConverterRead More
Reviews
There are no reviews yet.