5pcs 110-220V XH-W1818 High Precision Microcomputer Temperature Controller Circular Digital Display Embedded thermostat
$81.24
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Feature
Product Name:High precision microcomputer temperature controller
Product model:XH-W1818
Temperature range:-50~110°C
Resolution:0.1 ° C
Temperature control range:-50~110°C
Temperature control accuracy:1 ° C
Temperature probe:NTC10K (B3950) L=1M
Supply voltage:AC220V
Applicable environment:-25~55°C Humidity 50%-85%
Output type:10A relay output
Appearance size:diameter 80mm
Opening size:diameter 61mm/3mm
How to use
1. Connect the power supply and load according to the instructions. Please do not overpressure and overload.
2. Setting mode, long press SET button for 5 seconds will display P0. Press SET button shortly to set H to heating mode and C to cooling mode (up and down button to switch)
3. Set the stop temperature, press the SET button once to flash the screen, and then press the up and down keys to set the desired stop temperature.
4. Press and hold the SET button for 5 seconds to display P0, press the up and down keys to switch to P1, then press the SET button to set the difference back (press the up and down keys to adjust). If the heating mode H needs to control the temperature between 36-38 degrees , then the stop temperature is set to 38 degrees and the back difference is set to 2 (the highest temperature minus the lowest temperature)
5. Indicator light. SET light is on to indicate that the parameter is being set; OUT indicator is flashing to indicate the start delay, and always on to indicate the output.
Setting function description
Press SET button for 5 seconds to enter internal parameter setting, up and down button to switch P0-P7
Code:Code description:Setting:Factory setting
P0:Operating mode:C/H:H
P1:Backlash setting:0.1-30:2
P2:Set upper limit:Max. 110 ° C:110°C
P3:Set lower limit:Min. -50 ° C:-50°C
P4:Temperature correction:-10~10°C:0°C
P5:Delayed start:0-10 minutes:0
P6:High temperature alarm:-50~110°C:110°C
P7:Data lock:OFF/ON:OFF
P0:Heating and cooling mode H/C
The low temperature start is the heating mode, set to H. For example:the actual temperature is 21 ° C, the temperature needs to be controlled between 36-38 ° C, we set P0 to H heating mode.
The high temperature start is the cooling mode, set to C. For example:the actual temperature is 38 °C, and the temperature needs to be controlled between 24-26 °C. We set P0 to C cooling mode.
P1:Hysteresis setting
In heating mode (H):The measured value starts the output heating to the set value when the set value – hysteresis.
For example, to control an indoor temperature between 36 and 38 ° C, the actual temperature is 20 ° C, heating equipment is required to heat room, P0 is set to H, the stop temperature is set to 38 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 38-36 = 2)
In cooling mode (C):When the measured value >= set value + hysteresis, the output cooling is started until the set value stops.
For example, to control an indoor temperature between 24 and 26 ° C, the actual temperature is 36 ° C, the cooling equipment is required to cool room, P0 is set to C, the stop temperature is set to 24 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 26-24 = 2)
P2:Limit the maximum set value (non-temperature control setting):up to 110 °C
For example, if P2 is set to 50 °C, then when you set the operation, the maximum temperature can only be set to 50 °C.
P3:Limit the min. set value (non-temperature control setting):min. -50 °C
For example, if P2 is set to 20 °C, then when you set the operation, the set min. temperature can only be 20 °C. Since P2 is set to 50 degrees and P3 is set to 20 degrees, then you set is only Can be adjusted between 20~50 degrees.
P4:Temperature correction
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
For example, the probe measurement temperature is 22.8 ° C, the standard temperature is 24.2 ° C, you need to increase the height by 1.4 degrees, set P4 = 1.4
For example, the probe measurement temperature is 26.31 ° C, the standard temperature is 23.5 ° C, it needs to be lowered by 2.8 degrees, and P4 = -2.8 can be set.
P5:Delay start time:0~10 minutes
When controlling the cooling of the compressor equipment, the delay time can be set as required. When the controller outputs, the equipment will not start immediately, and it needs to be started after the set delay time has elapsed. (Non-compressor control is set to 0)
P6:High temperature alarm
When the measured value is greater than the alarm value, the screen temperature flashes and the drip sound alarm, the output is forcibly turned off in the heating mode, and the output is not turned off in the cooling mode.
P7:Data lock function
Turn on the data lock, P7 is turned ON to save the current setting parameters without being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to enter P7 to turn OFF to turn off the data lock function.
Package includes
5 x High precision microcomputer temperature controller
Weight | 0.45 kg |
---|
Customers Also Viewed
3Pcs MPR121-Breakout-v12 Proximity Capacitive Touch Sensor Controller Keyboard Development Board
$16.16Motherboard & Development BoardAdd to cartDescriptionThis is a breakout board for Freescale’s MPR121QR2. The MPR121 is a capacitive touch sensor controller driven by an I2C interface.The chip can control up to twelve individual electrodes, as well as a simulated thirteenth electrode. The MPR121 also features eight LED driving pins. When these pins are not configured as electrodes, they may be …
220V 100A Class A Power Amplifier Soft Start Delay Temperature Protection Board with Gas Discharge Tube
$24.95Relay ModuleAdd to cartFeatures100% Brand new and high quality.FunctionThe board is equipped with a gas discharge tube. The gas discharge tube is composed of a pair of cold cathode plates which are separated from each other and enclosed in a ceramic tube filled with a certain inert gas (Ar).The gas discharge tube is turned off under normal operating …
Excellway Terminals 40 Pcs 2p 3p 4p 5pin Right angle JST-XH Male Female Lipo Balance Connector
$36.44ConnectorsAdd to cartSpecificaiton Brand:Excellway Pitch:2.54mm Current Rating:1A AC, DC Voltage Rating:125V AC, DC Temperature Range:-25 deg C ~ +85 deg C Insulation Resistance:100M Omega Min. Wire Range:AWG 24~ 32 Insulation O.D.:1.00mm ( Max.) Withstanding Voltage:500V AC/minute Features These work great with all your typical and breadboard style pin connectors and sockets. This kit comes with the most …
HBV-1466FF Fixed Focus 5MP OV5640 FPC Camera Module USB 5 Million Pixels IP Camera Module
$42.85Other Module BoardAdd to cartSpecificationsModel No.:HBVCAM-1466FFModel Size:68.2mm ≠ 26mm ≠ 6mm÷0.2MMTemperature (Operation):-30C to 70CTemperature (Stable Image):0C to 50CAssembly technique:SMT (ROSH)Focus:FixedObject distance:30CM-infinitResolution:800LW/PH (Center)Interface:USB 2.0Power:USB bus powerMaximum Power consumption:940 mWPackage:Anti-electrostatic trayOperating system request:Win XP/win 7,8 / vista /android 4.0/ mac /Linuxwith uvcCertifications:FCC and CEActive Array Size:2592*1944Sensor:OV5640 (1/4” )Sensitivity:600mv /(lux-sec)Pixel Size:1.4┢m x1.4┢mMaximum Image Transfer Rate:MJPEG 1024×768 30FPS / YUY2 160×120 30FPSMJPEG 1280×720 …
HBV-1466FF Fixed Focus 5MP OV5640 FPC Camera Module USB 5 Million Pixels IP Camera ModuleRead More
10pcs 40x40mm Small Fan 4010S Computer Chassis CPU Fan 2 Line with Plug
$19.84Electronic Accessories & SuppliesAdd to cartDescriptionAppearance size:40mm x 40mm x 10mmSpeed reference:4000 ± 10% RPMNoise Reference:18DBAir volume reference:18.17-25.97CFMRated voltage:12VRated current:0.10APackage included10 x Fan
Reviews
There are no reviews yet.