5pcs 110-220V XH-W1818 High Precision Microcomputer Temperature Controller Circular Digital Display Embedded thermostat
$81.24
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Feature
Product Name:High precision microcomputer temperature controller
Product model:XH-W1818
Temperature range:-50~110°C
Resolution:0.1 ° C
Temperature control range:-50~110°C
Temperature control accuracy:1 ° C
Temperature probe:NTC10K (B3950) L=1M
Supply voltage:AC220V
Applicable environment:-25~55°C Humidity 50%-85%
Output type:10A relay output
Appearance size:diameter 80mm
Opening size:diameter 61mm/3mm
How to use
1. Connect the power supply and load according to the instructions. Please do not overpressure and overload.
2. Setting mode, long press SET button for 5 seconds will display P0. Press SET button shortly to set H to heating mode and C to cooling mode (up and down button to switch)
3. Set the stop temperature, press the SET button once to flash the screen, and then press the up and down keys to set the desired stop temperature.
4. Press and hold the SET button for 5 seconds to display P0, press the up and down keys to switch to P1, then press the SET button to set the difference back (press the up and down keys to adjust). If the heating mode H needs to control the temperature between 36-38 degrees , then the stop temperature is set to 38 degrees and the back difference is set to 2 (the highest temperature minus the lowest temperature)
5. Indicator light. SET light is on to indicate that the parameter is being set; OUT indicator is flashing to indicate the start delay, and always on to indicate the output.
Setting function description
Press SET button for 5 seconds to enter internal parameter setting, up and down button to switch P0-P7
Code:Code description:Setting:Factory setting
P0:Operating mode:C/H:H
P1:Backlash setting:0.1-30:2
P2:Set upper limit:Max. 110 ° C:110°C
P3:Set lower limit:Min. -50 ° C:-50°C
P4:Temperature correction:-10~10°C:0°C
P5:Delayed start:0-10 minutes:0
P6:High temperature alarm:-50~110°C:110°C
P7:Data lock:OFF/ON:OFF
P0:Heating and cooling mode H/C
The low temperature start is the heating mode, set to H. For example:the actual temperature is 21 ° C, the temperature needs to be controlled between 36-38 ° C, we set P0 to H heating mode.
The high temperature start is the cooling mode, set to C. For example:the actual temperature is 38 °C, and the temperature needs to be controlled between 24-26 °C. We set P0 to C cooling mode.
P1:Hysteresis setting
In heating mode (H):The measured value starts the output heating to the set value when the set value – hysteresis.
For example, to control an indoor temperature between 36 and 38 ° C, the actual temperature is 20 ° C, heating equipment is required to heat room, P0 is set to H, the stop temperature is set to 38 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 38-36 = 2)
In cooling mode (C):When the measured value >= set value + hysteresis, the output cooling is started until the set value stops.
For example, to control an indoor temperature between 24 and 26 ° C, the actual temperature is 36 ° C, the cooling equipment is required to cool room, P0 is set to C, the stop temperature is set to 24 degrees, and P1 is set to 2. (High temperature – low temperature = hysteresis, 26-24 = 2)
P2:Limit the maximum set value (non-temperature control setting):up to 110 °C
For example, if P2 is set to 50 °C, then when you set the operation, the maximum temperature can only be set to 50 °C.
P3:Limit the min. set value (non-temperature control setting):min. -50 °C
For example, if P2 is set to 20 °C, then when you set the operation, the set min. temperature can only be 20 °C. Since P2 is set to 50 degrees and P3 is set to 20 degrees, then you set is only Can be adjusted between 20~50 degrees.
P4:Temperature correction
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction + correction value
For example, the probe measurement temperature is 22.8 ° C, the standard temperature is 24.2 ° C, you need to increase the height by 1.4 degrees, set P4 = 1.4
For example, the probe measurement temperature is 26.31 ° C, the standard temperature is 23.5 ° C, it needs to be lowered by 2.8 degrees, and P4 = -2.8 can be set.
P5:Delay start time:0~10 minutes
When controlling the cooling of the compressor equipment, the delay time can be set as required. When the controller outputs, the equipment will not start immediately, and it needs to be started after the set delay time has elapsed. (Non-compressor control is set to 0)
P6:High temperature alarm
When the measured value is greater than the alarm value, the screen temperature flashes and the drip sound alarm, the output is forcibly turned off in the heating mode, and the output is not turned off in the cooling mode.
P7:Data lock function
Turn on the data lock, P7 is turned ON to save the current setting parameters without being changed. At this time, the setting temperature and function are invalid. If you need to modify, you need to enter P7 to turn OFF to turn off the data lock function.
Package includes
5 x High precision microcomputer temperature controller
Weight | 0.45 kg |
---|
Customers Also Viewed
10Pcs RobotDyn Thyristor AC Switch Relay Module 3.3V/5V Logic AC 220V/5A Peak 10A
$54.90Relay ModuleAdd to cartFeatureIf you need to control the AC power (lights, home equipment’s), a thyristor is what you need. This is a very common thyristor module with very low on-resistance and a control voltage, that is compatible with any 3.3V or 5V micro-controller or mechanical switch. This allows you to control high-power devices with very low-power control …
10Pcs RobotDyn Thyristor AC Switch Relay Module 3.3V/5V Logic AC 220V/5A Peak 10ARead More
Glass Transparent Cell Spreader Bacteria Wide Spreading Bar Polished Ends Biological Experiment
$15.30Laboratory BottleAdd to cartDescriptionGlass Transparent Wide Cell Spreading Bar Used for Biological ExperimentSpecificationMaterial:GlassColor:ClearFeatures1.Suitable for us to swirl the spreader around the dish to evenly distribute the cells or bacteria with applying much pressure.2.Smooth shape end makes spreading easy.3.Eco-friendly Material and good design. 4.Easy sterilization.NoticeThe spreader should be back in alcohol or ethanol to keep it clean and prevent …
3pcs 78M05 Mini Voltage Regulator Module with Pin High Accuracy Low Power Consumption LO7805MA 5V
$6.93Boost & Buck ModuleAdd to cartFeatures1. Used in small power motors, cameras, electric toys, LED lighting, etc.2. The product has high accuracy whose range is ±2%3. With thermal overload protection, short circuit protection and output switching SOA protection4. The product has ±2% output voltage toleranceSpecificationsHigh Accuracy:±2%Quiescent Current:6mAWorking Temperature:-40→ ~ + 125→Size:18 x 10.5 x 5mm5VInput Voltage:DC 7-25V, Output Voltage:DC 5VOutput …
234Pcs Upgraded Outdoor Emergency Survival Kit Gear SOS First Aid for Home office Boat Camping Hiking
$64.79Lab Clamp & StandAdd to cartSpecificationBag Color:RedSize:260*80*180mm(L*W*H)Quantity:234 PCSFeatures– Small size and easy to carry.– First aid dedicated, fully equipped.– A good choice for emergency situation.– Essential items for going out or at home.– Multifunctional, practical and convenient.– With quality hardware zipper, easy to open and close.– Made of high quality material, waterproof, high wear resistance.– Can be used for outdoor …
5Pcs 3S 12.6V 6A BMS Li-ion Lithium Battery Protection Board 18650 Power Bank Balance Battery Board
$24.04Battery Protection ModuleAdd to cartFeatureSize:about 56×33.5x12mmUpper operating current:8AUpper transient current:40A÷5AOvercharge range:4.25÷0.05VOver disvoltage range:2.5÷0.05VCharging voltage:12.6-13VFunction:over charge/ over discharge/short circuit/ over current protectionPackgae includes5 x Battery Protection Board
3Pcs Double End Cleaning Brush Set Brass Steel Nylon Wire Brush Kit
$10.11Laser SightAdd to cartSpecificationMaterial:Brass, Steel, NylonLength:17.2cm / 6.8inchLarge End Brush Size (L*W*H):37x7x12mmSmall End Brush Size (L*W*H):22x2x8mmFeatures– Includes 3 brushes, 3 types of double-ended brushes:Brass, Steel, Nylon.– Versatile cleaning capabilities with both a large and small end, 7 inch total length for cleaning all sorts of hard-to-reach spaces.– The steel and brass brush help to clean stubborn areas on …
3Pcs Double End Cleaning Brush Set Brass Steel Nylon Wire Brush KitRead More
100-240V Power Adapter Power Supply Adaptor Plugs AU Standard
$16.19AC/DC AdaptersAdd to cartPower Supply Adaptor for Makita Radio BMR100 BMR100W BMR102 BMR105 DMR105SpecificationsInput:AC 100-240V, 50/60HzOutput:DC 12V 1AColor:BlackSize(Approximately):7.8*4.9*3.2cm(approx.)Wire length(Approximately):93cmPlug type:AU PlugFeatures-Voltage Protection-Short Circuit Protection-Current Protection-Sealed for protection against moisture and humidityApplicationFor Makita Radio BMR100 BMR100W BMR102 BMR105 DMR105Package included1 x Adaptor
Reviews
There are no reviews yet.