QFRD-72 ON/OFF Relay Module infinite Cycle Time Adjustable Timer Relay
$10.92
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Specifications
Voltage:AC 100V-250V, can be used for 100V/110V/120V/127V/220V/230V/240V mains.
Power consumption
Output:Active output with the same output voltage as the input voltage. Do not exceed 10A at most.
Life:100,000 movements
Input:Passive switch input, the green light will be on first after starting, and will stay in red after stopping.
Time range:0.5 seconds – 1000 minutes
Time accuracy:Range maximum * 0.001, ie 1000 resolution.
Input (start button):Passive switch input, the green light will be on first after starting, and will stay in red after stopping.
Function:With start/stop function, the module enters the infinite loop mode after starting, and the relay works on and off according to the set time.
Dimensions:length 88mm * width 38mm * height 22mm or less
Screw hole:center distance 83mm * 33mm, aperture 3.2mm
Terminal
–>N connected to the load N line, most appliances do not need to strictly distinguish the LN line
–>L1 is connected to the load L line, most appliances do not need to strictly distinguish the LN line
–> The normally closed end of the LNCL line output is generally not connected.
Instructions
Time can be set in both power-on and power-off states
1.ON duration setting
The potentiometer adjustment time under the RUN TIME flag is clockwise for increasing the length and counterclockwise for shortening the duration.
The left side of the dial switch on the potentiometer is the time range setting. The adjustment range of the adjustable resistor after dialing is 0-100; the range after dialing is 0-1000.
The right side of the dial switch on the potentiometer is the unit setting. Dial down to Sec. The unit is seconds; dial to Min. The unit is minutes.
2.OFF duration setting
The potentiometer adjustment time under the OFF TIME flag is clockwise for increasing the length and counterclockwise for shortening the duration.
The left side of the dial switch on the potentiometer is the time range setting. The adjustment range of the adjustable resistor after dialing is 0-100; the range after dialing is 0-1000.
The right side of the dial switch on the potentiometer is the unit setting. Dial down to Sec. The unit is seconds; dial to Min. The unit is minutes.
3. Start button
Connect to the self-reset button, press once to switch to the green light, indicating that the running state, the module will automatically work according to the set running time and stop time, infinite loop. At this point, press the start button again, the module will switch to red light, indicating that it is in a stopped state.
4. Example of time setting
Demand:20 seconds on, 30 minutes off, infinite loop.
Settings
(1). Set the running time range to 0-100;
(2). Dial the running time unit to the second;
(3). Rotate the running time potentiometer to the 20 position, which is 20/100 from the left;
(4). Set the stop time range to 0-100;
(5). Dial the stop time unit to the minute;
(6). Rotate the stop time potentiometer to the 30 position, that is, the position from the left 30/100;
Note:The position of the potentiometer can also be quickly located by measuring the voltage. The center arm is adjusted to a minimum of 0V and the highest position is 5V. For example, you need to adjust to 20, that is, 20/100*5V=1.0V; to adjust to 30, then 30/100*5V=1.5V
Applications
It is used for reciprocating stroke control, or repeated power-off of equipment and product aging test.
Warmly Noted
1. The start button can be used with a current of 0.1A or more.
2. The button output line is equipped with strong electricity. When installing, be sure to meet the creepage distance requirements to prevent personal contact with the charged body.
3. It is not necessary to start the input. You can short the two terminals with wires, so that the power will start to run infinitely without buttons.
Package Included
1 x QFRD-72 ON/OFF Relay Module Infinite Cycle Time Adjustable
Weight | 0.04 kg |
---|
Customers Also Viewed
5x 10x USB 8 LED Lights Handheld Stand Desktop Reading Magnifier
$24.29PhysicsAdd to cart5x 10x USB Eight 8 LED Lights Handheld Stand Desktop Reading Maintenance Multipurpose Magnifier 75RCDescription1. [2 In 1 Design]:It is not only a handheld magnifier, but also a desktop stand magnifier. It can be used as a desk magnifier by pulling its stand and placing it on a table. It can also be folded up …
5x 10x USB 8 LED Lights Handheld Stand Desktop Reading MagnifierRead More
DALY BMS 16S 48V 30A 40A 60A 3.2V 18650 Bluetooth 485 to USB Device NTC UART Software Togther Lion LiFepo4 Battery BMS
$12.14Battery Protection ModuleAdd to cartType 30A com UART BT / Type 30A com UART 485 / Type 30A com UART 485 CAN / Type 40A com UART BT / Type 40A com UART 485 / Type 40A com UART 485 CAN / Type 60A com UART BT / Type 60A com UART 485 / Type 60A com UART 485 CAN / Type USB to CAN box / Type USB to RS485
5Pcs Geekcreit 328P Multifunction Expansion Board V3.0 for NANO UNO
$24.26Expansion Board & ShieldAdd to cartDescriptionThe extension board specifically for the NANO , welding on two rows of pins, can be used in the duemilanove 2009, U N O R1Package included5 x 328P Multifunction Expansion Board V3.0
20pcs LilyPad MCP9700 Temperature Sensor Module
$55.07Sensor & Detector ModuleAdd to cartDescriptionDetecting temperature changes has never been easier. The MCP9700 is a small thermistor type temperature sensor. This sensor will output 0.5V at 0 degrees C, 0.75V at 25 C, and 10mV per degree C. Doing an analog to digital conversion on the signal line will allow you to establish the local ambient temperature. Detect physical …
IO22C04 4 Channel Pro Mini Relay Module Expansion Board Multi-function Delay Relay PLC Power
$24.04Relay ModuleAdd to cart>>>Manual:Click here to openFeatures– Operating voltage:power supply 1,DC 6.5-25V; power supply 2,DC 5V– Operating Current:Standby current (all relays closed) 15mA, 1 relay open 45mA, 2 relays open 77mA, 3 relays open 109mA, 4 relays open 140mA– Size:80x66x19mm– Weight:79g- On-board resources:4x opto-isolated inputs (low level trigger, NPN type), 4x buttons, 1 4 bit digital tube display, …
1-1000M 3W HF FM VHF UHF FM Shortwave Broadband Amplifier Upgrade Improved Version
$30.60Other Module BoardAdd to cartApplicationsBroadband RF power amplification, suitable for HF FM VHF UHF FM transmission of various radio applications, short-wave FM remote control toys, radio walkie-talkies, digital radio stations, etc., can output up to 3 watts, 15V voltage supply, 1MHZ to 1000MHZ can work frequency range.Technical indicators1. The supply voltage Voltage:DC + 12 ~ 15V (typical 15V @ …
1-1000M 3W HF FM VHF UHF FM Shortwave Broadband Amplifier Upgrade Improved VersionRead More
Geekcreit LTDZ 35M-4400M Handheld Simple Spectrum Analyzer Measurement of interphone Signal
$159.96Test & Measuring ModuleAdd to cartNew update version:Update from December, please use the new manual.Introduction:>>>Click here to openThis product uses the local oscillator signal and the external test signal to obtain the difference frequency signal, and calculates the amplitude of the external test signal through the detector. Using a high-precision VCO source, the heterodyne signal frequency can be measured very …
Geekcreit LTDZ 35M-4400M Handheld Simple Spectrum Analyzer Measurement of interphone SignalRead More
Reviews