3pcs XH-W1321 0.1 Digital thermostat Mini Embedded Blue Digital Display Switch Temperature Controller with Waterproof NTC Sensor Meter
$30.89
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Specifications
Product Name:Miniature embedded digital display thermostat
Product Model:XH-1321
Material:ABS
Case Color:White
LED Color:Blue
Input Voltage:DC12V
Temperature Measurement Range:-50-110→
Temperature Control Range:-50-110→
Control Accuracy:0.1→
Display Accuracy:0.1→
Measuring Input:NTC10K Waterproof Probe L=1 Meter
Output Type:Relay Output(Output Switch)
Output Capacity:10A
Size (Length x Width x Height):about 56 x 38 x 32mm (2.17 x 1.50 x 1.26 Inch )
Opening hole size:46 x 34mm
Key Function
SET:Press once during normal use, directly enter the stop temperature setting state, use the up and down keys to set the required stop temperature, long press to enter the internal setting menu.
UP:After long press the setting button to enter the internal setting, increase the value setting by the up button.
DOWN:After long press the setting button to enter the internal setting, use the up button to decrease the value setting.
Code:Description:Setting range (method):Factory settings
P0:Operating mode:H/C:C
P1:Backlash setting:0.1-50:2
P2:Temperature correction:-9.9~+9.9°C:0
P3:Delayed start:0-9:0
Detailed Code Descriptions
P0:Working mode:This value must be set when the thermostat is used for the first time. If it is used for heating heating, set to H, if it is used for cooling cooling, set to C.
P1:Hypothesis setting:Press and hold the setting button for 3 seconds to enter the internal menu, select P1, and press the setting button again to enter the hysteresis value setting state. The hysteresis is the difference required when the thermostat reaches the set temperature and stops working again. For example, it is set to the heating mode. When it is heated to 40 degrees, it stops at 35 degrees and starts to return. The difference is 5
P2:Temperature correction:Press and hold the setting button for 3 seconds to enter the internal menu. Press the up and down keys to select P2, press the setting button again, and set the required calibration temperature by the up and down keys. In the setting, if the detected temperature value is 0.5 °C larger than the actual temperature value, the calibration temperature to be set is -0.5 °C. If the detected temperature value is 1 °C smaller than the actual temperature value, the calibration temperature to be set is 1 °C, and the detection temperature +-calibration temperature = actual temperature.
P3:Delay start:Press and hold the setting button for 3 seconds to enter the internal menu, select P3 by the up and down keys, press the setting button again, and set the required delay time (minutes) by the up and down keys. The delay start is generally used for compressor refrigeration. If it is used in the refrigerator freezer, this value needs to be set. According to the compressor back pressure, the set value is usually 3-6 minutes, if it is not used to control the compressor or no delay. Function, skip this item directly.
Instructions
Set the difference back:Why set the backlash setting When you control the device, the temperature will rise or fall back. How many degrees does the temperature change If you want the temperature to change by 10°, the device needs to set the difference back to 10. By setting the difference back, the device can cycle through the temperature range.
Set the stop temperature:press the set button once in the normal display state to stop the temperature value flashing. You can set the desired stop temperature value by using the up and down keys.
How to set factory settings are restored:Press and hold the up and down keys while the power is on, the digital tube display 888 will then automatically jump to the detection temperature.
Heating mode setting method
Setup steps
The first step is to set P0=H
The second step sets the stop temperature
The third step sets the hysteresis value
Setting method
1. Press and hold the setting button to enter the internal menu and set P0 to H.
2. Press the setting button to stop the temperature flashing, and the up and down keys to set the temperature.
3. Press and hold the setting button to enter the internal menu and set the P1 hysteresis setting.
Use Cases
Control the water heater, heat it to 65 ° C to stop, the temperature drops back to 50 ° C and start heating again, how to set
Step 1:Determine the working mode as heating mode and set P0 to H
Step 2:Press the setting button to stop the temperature flashing. Set the starting temperature to 50 °C with the up and down keys.
The third step:stop at 65 °C, start again at 50 °C, so the return difference needs to be set to 65-50=15, enter the internal menu and set P1 to 15, the heating case is set!
Cooling mode setting mode
Setup steps
The first step is to set P0=C
The second step sets the stop temperature
The third step sets the hysteresis value
Setting method
Press and hold the setting button to enter the internal menu and set P0 to C.
Press the setting button to stop the temperature flashing, and the up and down keys to set the temperature.
Long press the setting button to enter the internal menu, set the P1 backlash setting
Use Cases
Control the farm, ventilate to 26 ° C to stop, the temperature rises to 28 ° C to start the refrigeration again, how to set up
The first step:determine the working mode is cooling mode, set P0 to C
Step 2:Press the SET button to stop the temperature flashing. Set the stop temperature to 28 °C with the up and down keys.
The third step:stop at 26 ° C, start again at 28 ° C, so the return difference needs to be set to 28-26 = 2, enter the internal menu to set P1 to 2, the cooling case is set!
Package includes
3 x Miniature embedded digital display thermostat
Weight | 0.132 kg |
---|
Customers Also Viewed
MSI.SDR Panadapter Kit Broadband Software Radio MSI.SDR Receiver 10KHz-2GHz Panadapter Module Compatible with SDRPlay RSP1 Software
$112.66Electronic Accessories & SuppliesAdd to cartDescriptionMSI.SDR is a powerful broadband full-featured SDR receiver.Covers frequencies from 10KHz to 2GHz. Just connect a PC and an antenna. The function of the receiver can be provided.Compatible with all SDRPlay RSP1 software. Compatible with popular SDR software platforms You can monitor up to 10 MHz of spectrum simultaneously. Enjoy all modes of operation. Small …
5pcs JDY-18 bluetooth Module 4.2 High Speed Transmission BLE Mesh Networking Master
$30.17Other Module BoardAdd to cartProduct introductionThe JDY -18 transmission module is based on the bluetooth 4.2 protocol standard, the working band is 2.4GHZ, the debugging mode is GFSK, the maximum transmission power is 0dB, the maximum launch distance is 60 meters. The imported original chip is designed to support the user to modify the equipment name, service UUID, transmit …
5pcs JDY-18 bluetooth Module 4.2 High Speed Transmission BLE Mesh Networking MasterRead More
4 Coil Brushless Motor Fan Blade High-speed Turbine Hall Electric Machine Model
$168.87PhysicsAdd to cartDescriptionFour Coil Brushless Fan Blade High-speed Turbine Hall Electric Machine Stirling Engine Model SpecificationName:Four Coil Brushless Motor Fan ModelCoil:Four Coil DesignPrinciple Design:Electromagnetic Induction, Mechanics, Hall Sensor.Size:155*125*150mmPower:8WWorking Voltage:12VSpeed:3000r/minAdapter Input Voltage:AC100-240V 50/60HzAdapter Output Volatage:DC12V 3AType:General motor:Hall electric motorDegree of loss:carbon brush,easily consumable:brushless,durableStructure:complex:simple easy maintenanceQuality:low:highTechnology integration:low:highWorking Life:short:longTheory1.Hall effect is a semiconductor sensor, under the action of loren magnetic …
4 Coil Brushless Motor Fan Blade High-speed Turbine Hall Electric Machine ModelRead More
TA8131 Digital Luxmeter illuminance Light Meter 100000Lux Lux/FC illuminometer
$52.64Laboratory Thermostatic DevicesAdd to cartDescription* 3-1/2 digit LCD display, Max reading 1999.* Hand or Auto measuring range:0~100,000Lux.* LUX/FC Unit selection.* MAX and MIN Reading Hold Function.* Storage 50 datas and delay logging function(1 to 60 seconds selection).SpecificationsItem:Digital Lux meterModel:TA8131Brand:TASIMeasuring Range:100Lux, 1000Lux, 10000Lux, 100000Lux. (10/100/1000/10000 Fc)Resolution:0.1LuxAccuracy:±3% rdg ± 10dgts( ±4% rdg ± 10dgts(>10,000 lux)Total accuracy:for C.I.E standard illuminate A(2856K)Sample Rate:2times/SRepeatability:±2%Range …
TA8131 Digital Luxmeter illuminance Light Meter 100000Lux Lux/FC illuminometerRead More
Aluminum Alloy 100W 28KHz Ultrasonic Piezoelectric Transducer Cleaner Silvery
$51.62Electronic Accessories & SuppliesAdd to cartFeatures1. Low heat2. Good thermal stability3. Frequency and static capacitance consistency strong.4. Resonance impedance is low.5. The average length of life.6. It can be widely used in a variety of ultrasonic cleaning equipment.7. High performance:mechanical Q value, high vibration efficiency, high amplitude8. The full range (17KHZ-200KHZ), to meet the different needsParameterMaterial:Aluminum AlloyPower:100WResonant frequency:28 ± 0.5 …
Aluminum Alloy 100W 28KHz Ultrasonic Piezoelectric Transducer Cleaner SilveryRead More
10Pcs Mini DC-DC1.3A Voltage Converter Step Down Module 12V 24V to 5V 3.3V 9V with integrated inductor for 360 RC
$17.74Boost & Buck ModuleAdd to cartFeaturesThe maximum output current is 1.3A, and it is running within 1A for a long time;Non-isolated DC synchronous rectification with up to 94% conversion efficiencyOne-piece inductor, lower heat than ordinary shielded inductorUniversal, optional output voltage, spot welding directly on the boardOutput with LED indicator for easy and visual indication of voltage outputWith enable (EN) port, …
Reviews
There are no reviews yet.