XY-DJ01 DC6-30V 30A 1CH Digital Display Relay Module Delayed Power off Trigger Delay Cycle Timing Circuit Switch Rail Type
$26.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;
2. Support button trigger control, high and low level trigger, switch value control, support NPN, PNP sensor access, suitable for most occasions;
3. Wide voltage supply (6~30V),Rail installation, very convenient to use;
4. There is a key pausing function, with reverse connection protection, reverse connection does not burn;
5. Added sleep mode. After enabling, without any operation for about 5 minutes, the LCD backlight will be automatically turned off; any key to wake up;
6. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
7. All set parameters are automatically saved after power-off.
Operating mode
P0:After the signal is triggered, the relay is turned on for OP time, and then off; within the OP time, the signal is triggered again invalid
P1:After the signal is triggered, the relay is turned on for OP time and then off; within the OP time, the signal is triggered again to re-timing
P2:After the signal is triggered, the relay is turned on for OP time and then turned off; within the OP time, the signal triggers reset again, the relay is turned off, and the timing stops
P3:After the signal is triggered, the relay is turned off for CL time, and then the relay is turned on;
P4:After the trigger signal is given, the relay is turned on for OP time, the relay is disconnected for CL time, and then the above actions are cycled, the signal is given again in the cycle, the initial state is restored, and the timing is stopped; the number of cycles (LOP) can be set; the cycle ends, keep the relay off ;
P5:Give the trigger signal, after the relay is disconnected from the CL time, the relay will be turned on for OP time, and then cycle the above actions, give the signal again in the cycle, restore the initial state, and stop timing; the number of cycles (LOP) can be set; the cycle ends, keep the relay on ;
P6:After power-on, no trigger signal is needed, the relay is on for OP time, the relay is off for CL time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle is over, keep the relay off;
P7:There is no need to trigger signal after power-on, the relay is off CL time, the relay is on OP time, and the above actions are cycled; the number of cycles (LOP) can be set; the cycle ends and the relay is kept on;
P8:Signal hold function If there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing OP; during the timing, there is a signal again, and the timer is clear;
P9:Signal hold function If there is a trigger signal, the timer is cleared and the relay remains off; when the signal disappears, the relay is turned on after timing CL; during the timing, there is another signal, and the timer is cleared;
(P0~P7) mode, short press the pausing button, when the system does not trigger the timing, the system starts timing; when the system is already timing, the system pauses timing, the relay is disconnected, and flashes ‘OUT’ as a reminder;
In P8 P9 mode, the pausing button on the running interface is used as the trigger signal, and its button function is disabled by short press/long press;
Product parameter
Working voltage:6-30V power supply
Trigger signal source:high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
Output capacity:can control equipment within DC 30v 30A or AC 220v 30A
Quiescent current:15mA
Working current:50-130mA
Service life:more than 100,000 times;
Working temperature:-40-85→;
With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters are always remembered after power failure.
Timing range
0.01 second (minimum) ~ 9999 minutes (maximum) continuously adjustable
How to choose the timing range
In the OP/CL parameter modification interface, short press the pausing button to select the timing range;
XXXX No decimal point, timing range 1 second~9999 seconds
XXX.X The decimal point is in the tenth place, and the timing range is 0.1 seconds to 999.9 seconds
XX.XX The decimal point is in hundreds, and the timing range 0.01 seconds to 99.99 seconds
X.X.X.X All decimal points are lit, timing range 1 minute to 9999 minutes
For example, if you want to set the OP to 3.2 seconds, move the decimal point to the tens place, and the LCD will display 003.2
Parameter description:OP on time, CL off time, LOP cycle times (1-9999 times, ‘—-‘ represents infinite cycles)
parameter settings
a) Enter the setting interface by long pressing the setting button;
b) First set the work mode, the work mode flashes to remind, short press the increase/decrease button to set the work mode;
c) Short press the setting button, select the working mode, and enter the system parameter setting;
d) In the system parameter setting interface, short press the setting button to switch the system parameter to be modified, and short press/long press the increase/decrease button to modify;
(Note:Short press the setting button is invalid in P0~P3/P8/P9 mode);
e) In the OP/CL parameter modification interface, short press the pausing button to switch the timing unit (1s/0.1s/0.01s/1min)
f) After setting all parameters, long press the setting button to save the parameter setting and exit the setting interface;
Additional functions
a)Automatic sleep function:In the running interface (P0~P7 mode), long press the pausing button to start or close the automatic sleep function (LP selects on to start the sleep function, about five minutes, without any operation, the LCD backlight automatically turns off , The system is running normally, any key is pressed to wake up; off is to close the sleep function);
b) Parameter view:In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;
c) Display content switching:In P4 ~ P7 mode, short press the DOWN key to switch the display content (operating time/cycle times);
Package included
1 x Relay Module Switch
Weight | 0.03 kg |
---|
Customers Also Viewed
Ebyte E810-DTU(CAN-ETH) Smart Protocol Conversion GPRS Modem Modbus to TCP/IP CAN Bus Ethernet interface Modbus RTU Gateway
$96.54Smart ModuleAdd to cartSpecificationItemsDescriptionInterfaceEthernet:RJ45, 10/100MbpsCAN:1*5*3.81, ScrewingNetwork protocolIP,TCP/UDP, ARP, ICMP, IPV4Simple transparent transmissionTCP Server,TCP Client,UDP Server,UDP Client,Cloud transparent transmissionData Packing MechanismByte packing and time packingTCP Server connectionSupporting up to 6 TCP connectionsIP accessStatic IP,DHCPDNSSupportCAN Transmit baud rateA total of 15 baud rates from 6Kbps-1000KbpsCAN filtering modeUp to 8 filtration modesCAN data layoutProtocol formatParameter configurationWeb page configurationWorking current82mA@12VVoltage8V~28VDC,Over 28V may …
TP4056 Micro USB 5V 1A Lithium Battery Charging Protection Board TE585 Lipo Charger Module
$4.36Battery Protection ModuleAdd to cartSpecificationProduct name:Lithium Battery Charging BoardInput voltage:5VMaximum charging current:1000 mACharge cut-off voltage:4.2 V + / – 1%Battery overcharge protection voltage:2.5 VBattery over-current protection current:3 AInput interface:micro USBSize:27mm x 17mmHow to Use1. Input port with micro 5pin USB female, can directly use mobile charger for input to the lithium battery,and still retain the input voltage wiring solder …
TP4056 Micro USB 5V 1A Lithium Battery Charging Protection Board TE585 Lipo Charger ModuleRead More
10pcs 10-50W 15Wx2 Audio Power Amplifier DC 6 -18V TDA7297 Module Double Channel
$77.83Amplifier BoardAdd to cartFeatures– Working Voltage:6-18V DC– The onboard TDA7297 audio power amplifier chip, double channel 15WX15W– Speaker for European 4-8 10-50W use– Main pin has led chip, convenient external control device, the onboard– 5.08 (mm) distance between two p terminal 2 road, around a track connection output respectively– The onboard dial potentiometer, output size can adjust the …
10pcs 10-50W 15Wx2 Audio Power Amplifier DC 6 -18V TDA7297 Module Double ChannelRead More
LILYGO TTGO ESP32-Micro32 ESP-32-PICO WIFI Wireless bluetooth Control Module
$20.57Smart ModuleAdd to cartFeatureSeries:ESP32Model:ESP32-+MicroType:Regulator ICPower:1WApplication areas:household appliances, smart home, wearable devices, Internet of Things IoTDescriptionsESP32 vcc range:2.2V-3 6VVBAT:direct to battery (and charger)VUSB:direct to USB(5V)VCC:Output of regulator 3.3V/600mAUp to 250mA during RF transmissionsWirelessWifi:802.11 b/g/n/e/iWPA/WPA2/WPA2-Enterprise/SPSbluetooth:bluetooth 42BLESize:1.9×1.3cm/0.75×0.51inchNotePlease allow 1-3mm error due to manual measurement. pls make sure you do not mind before you bid.Due to the difference between different monitors, the …
LILYGO TTGO ESP32-Micro32 ESP-32-PICO WIFI Wireless bluetooth Control ModuleRead More
50Pcs 915MHz SW915-TH12 Copper Spring Antenna for Wireless Communication Module
$28.90Module ComponentsAdd to cartFeaturesSW915-TH12 copper spring antenna is a special antenna for 915MHz wireless communication system design. The antenna has good standing wave ratio, compact shape, ingenious structure, convenient installation, stable performance and good anti-vibration and aging ability.SpecificationFrequency range:915 MHz (+/-5)Standing wave ratioInput impedance:50Maximum power:5WGain:2.15 dBiWeight:1gHeight:12.5+/-1 mm (9T)Antenna color:copperInterface Form:Direct WeldingPackage included50 x Antenna
5Pcs 360 Degree Rotary Encoder Module Encoding Module
$11.83Other Module BoardAdd to cartFunctional characteristics and technical parameters 1)Nominal voltage:DC 5V 2)Wire A, B:0.5mA (Max 5mA; Min 0.5mA) 3)Common wire:1mA (Max 10mA; Min 0.5mA) 4)Temperature range:-30→ to+80→ 5)Output signal A , B phase position output square wave, when clockwise rotation, A phase position pull ahead B phase position 90 °, when anti-clockwise, B phase position pull ahead A …
5Pcs 360 Degree Rotary Encoder Module Encoding ModuleRead More
RD21F Delay Relay Module Power for Delay off Fan Module AC 100V-220V Time 0.2S-300min Adjustable Delay
$13.11Relay ModuleAdd to cartSpecificationsVoltage:100V-220V ACPower consumptionOutput:The output voltage is the same as the input voltage, and the maximum power supply capacity is 10A.Size:88* 36 * 22mmScrew hole:center distance 83mm * 31mm, aperture 3.2mmTime range:(4 files, selected by switch)First gear:range 0.2 seconds-30 seconds, accuracy:0.1 secondsSecond gear:range 0.2 seconds – 300 seconds (5 minutes), accuracy:0.3 secondsThird gear:range 0.2 seconds-30 minutes, …
Reviews
There are no reviews yet.