3Pcs J03 LED Digital Time Delay Relay DC 6-30V on off Trigger Delay Timming Timer Switch Micro USB Power Supply 5V 12V
$32.79
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. Wide voltage power supply (6 ~ 30V), supports microUSB 5.0V power supply, easy to use;
2. The interface is clear and simple, powerful, easy to understand, meet almost all your needs;
3. The emergency stop function (“STOP’key);With reverse polarity protection, reverse polarity will not burn the product.
4. Increase the sleep mode, if this mode is enabled, without any operation within 5 minutes, then automatically turn off the monitor, any key wake-up;
5. You can set a different OP, CL, LOP parameters, which are independent of each other, and are automatically saved;
6. After the module is powered down, all parameter settings are not lost.
Product parameters
1:Operating voltage:6–30V, support microUSB 5.0V power supply
2:Trigger Source:Active-high (3.0V-24V), have optocoupler isolation, can improve the system’s anti-jamming capability (customers can also shorting common ground).
3:Output capability:You can control the DC 30VDC 5A or 220VAC 5A device.
4:Quiescent Current:20mA; Operating Current:50mA
5:Life:more than 10 million times; Working temperature:-40→-85 →; Size:6.2*3.8*1.7cm.
6:With optocoupler isolation, enhanced anti-jamming capability, industrial grade board.
Special Note:The relay outputs are passive contact, just a switch.
Operating mode
P1:trigger signal, the relay is on ‘OP’ time, and then disconnect; in the ‘OP’ time, as follows
P1.1:signal is triggered again, invalid
P1.2:signal is triggered again, the clock is reset
P1.3:Signal trigger again, relay off, stop the clock;
P-2:trigger signal, the relay off ‘CL’ of time, the relay on ‘OP’ time, and then disconnect relay;
P3.1:trigger signal, the relay is turned on after the ‘OP’ time, the relay off ‘CL’ time, then the operation cycle, if the trigger signal period, the relay off, stop the clock; the number of cycles ( ‘LOP ‘) can be set.
P3.2:without triggering signal, the relay is on ‘OP’ time, the relay off ‘CL’ time, and has been cycling; frequency ( ‘LOP’) cycle can be set;
P-4:signal holding function. If there is a trigger signal timing is cleared, the relay remains on; when the signal disappears, after the timing ‘OP’ time, the relay is; if another signal during timing, timing is cleared.
Timing range
0.1 seconds (min) to 999 minutes (max) continuously adjustable
How to choose the time range
After setting the mode selection screen parameter value by a short press ‘STOP’ button to select the time range;
XXX. decimal point in the unit place, time range:1 second to 999 seconds.
XX. X decimal point in decade place, Timing range:0.1 seconds to 99.9 seconds
X. X. X. decimal full brightness, Timing range:1 minute to 999 minutes.
For example, you want to set ‘OP’ is 3.2 seconds, then move the decimal point to decade place, the digital display 03.2
Parameter description:’OP’ – conduction time, ‘CL’ – off time, ‘LOP’ – the number of cycles (1-999 times, ‘—‘ represents infinite loop).
These parameters are independent of each other, but is shared by each mode. For example, in P1.1 mode, set the on-time ‘OP’ is 5 seconds, if you switch to P1.2 mode, it’s ‘OP’ will be 5 seconds too.
In the main interface (display 000), short press ‘SET’ button will display ‘OP’ ( ‘CL’, ‘LOP’) and the corresponding time XXX;
Some parameters only mode ‘OP’ (such as the mode P1.1, P1.2, P1.3), short press the ‘SET’ key to display only the “OP” and the corresponding time;
Some models have parameters ‘OP’,’CL’, ‘LOP’ (such as the mode P3.1, P3.2), short press ‘SET’ button will display ‘OP’ and the corresponding time, “CL” and the corresponding time, “LOP” and the corresponding number of times;
In the main interface by short press ‘SET’ key to see information about the parameters of the current mode, very convenient!
How to set parameters
1. First, read the instructions to determine the required operating mode.
2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press ‘SET’ button for 2 seconds after release to enter mode selection interface; a short time by pressing ‘UP’, ‘DOWN’ key to select the mode (P1.1 ~ P-4).
3. Select the mode (such as P3.2), short press the ‘SET’ button, then the parameter to be set flashes ( ‘OP’on-time, ‘CL’ off time, ‘LOP’ cycles ( ‘—‘ represents infinite loop)), by ‘UP’, ‘DOWN’ keys to adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease one unit); then short press the ‘STOP’ key to select the decimal point position, select the time range (0.1 seconds to 999 minutes); short press the ‘SET’ button to set the next parameters of the current mode of procedure is as above.
4. After the parameters are set, long press ‘SET’ button for 2 seconds then release, the name of the current mode will flash once, and then return to the main screen, set the parameters of success!
The main interface:In the relay does not work status display ‘000’ (no decimal point), with a decimal point under relay state.
Mode selection screen:Long press the ‘SET’ key to enter, after setting is completed, long press the ‘SET’ key to exit back to the main screen.
‘STOP’ button extensions
Relays enable mode
1. ON:Relay allows conduction in the ‘OP’ on-time;
2. OFF:relay prohibit conduction is always closed;
In the main interface, short press the ‘STOP’ button to switch between ON and OFF, the current in which the state will flash, and then return to the main screen. (This feature is an emergency stop function, click off the relay)
Sleep mode
1. ‘C-P’ Sleep mode:five minutes without any operation, the digital display automatically turns off, the program running as usual;
2. ‘O-d’ normal mode:digital display always open;
Press the ‘STOP’ button for two seconds and then release to switch ‘C-P’ and ‘O-d’ state, in which the current state of flashes and then return to the main screen.
Package Included
3 x DC 1 Channel Time Delay Relay Module
3 x Shell Case
Weight | 0.222 kg |
---|
Customers Also Viewed
3Pcs 0.96 inch 4Pin White IIC I2C OLED Display Module 12864 LED
$38.88Display ScreenAdd to cartFeatureOLED Driver IC:SSD1306Resolution:128 x 64Visual Angle:>160°Input Voltage:3.3V ~ 6VCompatible I/O Level:3.3V, 5VMini Size:2.7 x 2.8cmOnly Need 2 I/O Port to ControlFull Compatible , 51NoteIf you decide to buy OLED display, you must confirm that you can make it work by yourself, we’ll haven’t any technology support. Thanks for your understanding and support.Package included3 x 0.96 …
3Pcs 0.96 inch 4Pin White IIC I2C OLED Display Module 12864 LEDRead More
Micro:Bit bluetooth 4.0 Low Energy Open Development Board for Programming
$60.06Raspberry Pi & Orange PiAdd to cartOverviewThe micro:bit is an open development board that allows you to run code on it and have access to all of the hardware.You can use your micro:bit for all sorts of cool creations, from robots to musical instruments – the possibilities are endless.This little device has an awful lot of features, like 25 red LED …
Micro:Bit bluetooth 4.0 Low Energy Open Development Board for ProgrammingRead More
500mL 24/40 Glass Filtering Flask Lab Filtration Conical Flask Bottle Laboratory Glassware
$58.71Glassware KitAdd to cartDescription– Flasks are glass or plastic containers for storing or collecting chemical samples or solutions in scientific laboratories.– It shaped like a cone with a wide, flat base that narrows to a neck opening, which can be closed with a stopper or cap.SpecificationMaterial:Borosilicate GlassCapacity:500mLFlask Style:Filtering (vacuum)Feature– The neck is 24/40 Ground Joint.Package Included1 x Glass …
500mL 24/40 Glass Filtering Flask Lab Filtration Conical Flask Bottle Laboratory GlasswareRead More
AC 100W 40KHZ Ultrasonic Cleaning Power Driver Board with 50W 40K Transducer 220V
$98.40Driver ModuleAdd to cartSpecificationsPower:220V 100WPendulum:50W 40KHZApplies to:Low-power ultrasonic cleaning machine, household cleaning machine, ultrasonic generator built machine.Features1. The ultrasonic generator can monitor the power system frequency ultrasound power.2. According to different requirements of users, real-time adjustment of various parameters, the power, amplitude, and running time.Circuit board and vibration head (ceramic transducer) Wiring instructions1. The board can not no-load …
AC 100W 40KHZ Ultrasonic Cleaning Power Driver Board with 50W 40K Transducer 220VRead More
5pcs 3S 18650 4A 11.1V BMS Li-ion Battery Protection Board 18650 Battery Charging Module Charger Electronic DIY
$19.48Battery Protection ModuleAdd to cartSpecificationsCharging Voltage:12.6V-13VOvercharge Voltage Range:4.25V-4.35V ± 0.05VOverpressure Voltage Range:2.3V-3.0V ± 0.05VUpper Limit Operating Current:3A-4AUpper Limit Instantaneous Current:9A-10AQuiescent Current:less than 30uAInternal Resistance:less than 100mohmEffective Life:more than 30,000 hoursOperating Temperature:-40- +50 degreesStorage Conditions:-40- +80 degreesSize:53 * 16 * 3mmShort Circuit Protection:protection, delay self-recovery ApplicationsThe power range is suitable for the following products:massager battery pack, LED light standby power …
3pcs infrared Light IR Camera Control Board for Surveillance Camera Night Vision CCTV Accessories
$10.52Driver ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.SpecificationsCurrent:700mAVoltage input:12V DCVoltage output:1.7-12V DCSize:38MM * 38MMPotential:good night vision effect; rigorous design, stable performance and strong anti-interference.Use:Suitable for all kinds of infrared lamp board drive, suitable for 1-6 infrared lampFunction:It can be …
Reviews
There are no reviews yet.