DC 24V Multifunctional Relay Module with LED Display Delay /Self Lock / Cycle / Timing
$13.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. New upgraded version with up to 20 functions preset to meet more application needs;
2. Optimize the software and hardware design, enhance the anti-interference ability of the module, and the system is more stable and reliable;
3. With power supply anti-reverse function, it will not damage the module due to wrong power supply;
4. The timing can be adjusted between 0.1 seconds and 270 hours;
5. All setting parameters can be saved, and the setting contents will not be lost when power is off.
Electrical Parameter
Working voltage:DC 24V
Working current:05V module is less than 90mA (less than 15mA when the relay is not operating, the display is less than 3mA)
Working temperature:-30 ° C – 70 ° C (limit range -40 ° C – 80 ° C)
Relay normally open port maximum load capacity:DC 0-30V/10A, AC 0-250V/10A
Relay normally closed port maximum load capacity:DC 0-28V/10A, AC 0-125V/10A
Dimensions:66mm x 41mm x 20mm (length x width x height)
Module Interface
Module voltage / signal input:3-wire interface, all interfaces have terminal blocks for user convenience
1, DC+:DC power supply positive
2, DC-:DC power supply negative
3, X1:input signal detection interface
Relay load output:3-wire interface, all terminals have terminal blocks
1, NO:relay normally open interface, the relay is suspended before the suction, after the suction is shorted with COM
2, COM:relay common interface
3, NC:relay normally closed interface, shorted to COM before the relay is sucked, suspended after suction
Module Function
Users can choose the required functions and parameters by simple operation. All parameters can be saved after power-off. The time parameter setting can be adjusted by 0.1 second minimum, and the precision is better than 0.01 second.
For example, if the user selects the function 16, the system will save the user settings, and the function 16 will be automatically run each time the phone is turned on until the user changes the settings again.
Function 1:Power-on delay pull-in:After the delay of T1 from the start of power-on, the relay is closed, T1 is adjustable between 0.1 seconds and 270 hours, and a high-level pulse signal is given to the X1 interface at any time. Reset and resume running;
Function 2:Power-on delay off:When the power is on, the relay is closed. After the T1 time is closed, the relay is disconnected. T1 is adjustable between 0.1 seconds and 270 hours. A high-level pulse signal is given to the X1 interface at any time. , this function resets and restarts;
Function 3:Timing pull-in and then disconnect:the relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 4:Timing disconnection and re-sucking:the relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 5:Infinite loop mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the above state is repeated; T1 and T2 are between 0.1 second and 270 hours. Adjustable between each time, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 6:Infinite loop mode 2:The relay immediately picks up when power is on, the relay turns off after the pull-in time T1 arrives; the relay picks up after the break time T2 arrives, and then repeats the above state, T1 and T2 are in 0.1 second-270 Adjustable between hours, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts operation;
Function 7:Limited cycle mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the NX times are repeated, T1 and T2 are at 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 8:Limited cycle mode 2:The relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and then the NX times are repeated, T1 and T2 are in 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 9:Self-locking relay mode:A high-level pulse signal is sent to the relay X1 interface, the relay is pulled in, and a high-level pulse signal relay is turned off.
Function 10:Level trigger relay mode (including delay off function):When the power is turned on, the relay is disconnected, and a high level signal is sent to the X1 interface. The relay immediately pulls in. After the X1 port signal disappears, the relay still pulls in. After the pull-in time T1 arrives, the relay is turned off, and T1 is adjustable between 0 seconds and 270 hours.
Note:In this function, if T1 is set to 0 seconds, it will become:X1 port has a high level signal relay to pull in, and if there is no signal, it will be disconnected immediately.
Function 11:Timing pull-up after triggering:the relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface, delaying the T1 time relay to pull in, T1 is adjustable between 0.1 seconds and 270 hours, repeating to the X1 interface a high-level pulse signal, repeating the above functions more than once;
Function 12:After the trigger, the timing is disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. The relay is closed, and the T1 time relay is disconnected. The T1 is adjustable between 0.1 seconds and 270 hours. Repeat a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 13:After the trigger, the timing is closed and then disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, T1 And T2 can be adjusted between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions;
Function 14:After the trigger, the timing is disconnected and re-closed:the relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the disconnection time T2 arrives. Pull-in, T1 and T2 are adjustable between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 15:Infinite loop mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected and then repeated. The above actions, T1 and T2 are adjustable between 0.1 second and 270 hours, and a high-level pulse signal is repeatedly given to the X1 interface, and the above functions can be restarted;
Function 16:Infinite loop mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives. Then repeat the above actions, delay T1 and T2 to be adjustable between 0.1 seconds and 270 hours, repeat a high-level pulse signal to the X1 interface, and restart the above functions;
Function 17:Limited cycle timing mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, and then the relay is turned off. Repeat NX times or more, T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, and the cycle number NX is adjustable between 1-9999 times. Repeating a high-level pulse signal to the X1 interface can restart the above functions;
Function 18:Limited cycle timing mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is immediately pulled in, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the break time T2 arrives. Pull in, then repeat NX times or more, at this time T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, the number of cycles NX is adjustable between 1-9999 times, repeating a high-level pulse signal to the X1 interface. , you can restart the above functions;
Function 19:Conditional cycle mode 1:The relay is disconnected at power-on, giving a high-level signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, as long as the X1 port is high. Does not disappear, the module will repeat the above action, T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Function 20:Conditional loop mode 2:The relay is disconnected at power-on, a high level signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives, as long as X1 The high level of the port does not disappear, the module will repeat the above action, the extension T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Package Included
1 x Multifunctional Relay Module
Weight | 0.027 kg |
---|
Customers Also Viewed
5pcs ST-LINK V2 Programmer Emulator Mini STLINK Downloader for STM8 / STM32 MCU Development Board
$45.35Test & Measuring ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.Description– Only U disk size and compatible with official ST-LINK V2.– Support official firmware upgrade, support all series of STM8 (SWIM interface), STM32(SWD interface).– Two-channel power output 5V / 3.3V and easier …
5pcs Breadboard Power Supply Module Circuit Test 3.3V 5V Switchable
$24.83Power Supply ModuleAdd to cartDescriptionThe size is exactly the same as most bread plates.Small size, suitable for all kinds of experimental equipment.It has the function of current limiting protection.The interface is popular, and the switching voltage can be switched.Input voltage:5VOutput voltage:5V/3.3V switchableOutput current:less than 500mASize:53 x 11mmPackage Included5 x Power Supply Module
3pcs Audio Speaker Protection Board Amplifier Components DC Protect Kit DIY
$24.37DIY Electronic KitsAdd to cartSpecificationInput voltage:AC12-15 VSize(L*W*H):6x 4 x 2.5 cm (Finished)FeatureWith power on delay (about 3 seconds) and DC protection (control voltage around 1 V)With LED status display, when the protection light, the normal work time offUsing 15 A large current relayWorking voltage aAC 12 to 15 V, need independent power supply.Package includes3 x Double-sided circuit boards 3 …
3pcs Audio Speaker Protection Board Amplifier Components DC Protect Kit DIYRead More
5Pcs AMS1117 3.3V Power Supply Module with DC Socket And Switch
$9.02Power Supply ModuleAdd to cartDescription1. onboard AMS1117-3.3 chip2. onboard DC input voltage range of 4.75 V to 12 V3. the onboard 7 * 7 self-locking switch, convenient to control power supply turned on and off during the test4. the onboard power light, indicating whether the power supply5. 4-way output voltage interface, convenient connection during the test6. The board size:48.5 …
5Pcs AMS1117 3.3V Power Supply Module with DC Socket And SwitchRead More
32Pcs Science Chemical Experiment Demonstration Tools Reagent Alcohol Lamp Full Set Storage Box
$89.79Lab Clamp & StandAdd to cartSpecificationType:Chemical Experiment BoxMaterial:Plastic, GlassFeatures1. High quality materials. Environmentally friendly and durable.2. Deepen understanding:thinking at your own hands can give your child a deeper understanding of knowledge.3. The variety of experimental tools is rich, which can meet different experimental needsPackage IncludedItem:QuantityBlue and Red Cup:2 SetFour Treasure Box:1 PcsAlcohol Lamp:2 PcsDropping Bottle:2 PcsSpray Bottle:1 PcsBule Dropping Bottle:3 …
3Pcs T2310 AC110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
$32.79Test & Measuring ModuleAdd to cartFeatureIndependent crystal oscillator, more accurate timing1. Convenient direct output wiring2. Add buzzer and audible alarm3. Add pause button to stop urgently5. Start and stop setting mode, provincial conversion, which is more convenient6. Automatically save when power off, run automatically when power on7. Timing units can be set separately, with 36 working combinations8. Timing range:0-999 seconds, …
5pcs 30CM 1M Portable Photosensitive Dry Film for Circuit Photoresist Sheet for Plating Hole Covering Etching for Producing PCB Board
$21.78Electronic Accessories & SuppliesAdd to cartFeaturesUniversal used in producing PCB board, attach on the PCB surface to make it photosensitive.Suitable for electroplating, hole covering and etching.Great hole covering ability.High resolution.Great adaptive capacity to different material.Durable in pH 8.0-8.5 situation.1.5mil dry film fully covers a 0.25inch height hole.Suitable for usual plating bath, no wrinkle or color error.SpecificationWidth:approx. 30 cm/11.81inchLength:approx. 100 cm/39.37inchOperating …
Reviews
There are no reviews yet.