DC 24V Multifunctional Relay Module with LED Display Delay /Self Lock / Cycle / Timing
$13.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. New upgraded version with up to 20 functions preset to meet more application needs;
2. Optimize the software and hardware design, enhance the anti-interference ability of the module, and the system is more stable and reliable;
3. With power supply anti-reverse function, it will not damage the module due to wrong power supply;
4. The timing can be adjusted between 0.1 seconds and 270 hours;
5. All setting parameters can be saved, and the setting contents will not be lost when power is off.
Electrical Parameter
Working voltage:DC 24V
Working current:05V module is less than 90mA (less than 15mA when the relay is not operating, the display is less than 3mA)
Working temperature:-30 ° C – 70 ° C (limit range -40 ° C – 80 ° C)
Relay normally open port maximum load capacity:DC 0-30V/10A, AC 0-250V/10A
Relay normally closed port maximum load capacity:DC 0-28V/10A, AC 0-125V/10A
Dimensions:66mm x 41mm x 20mm (length x width x height)
Module Interface
Module voltage / signal input:3-wire interface, all interfaces have terminal blocks for user convenience
1, DC+:DC power supply positive
2, DC-:DC power supply negative
3, X1:input signal detection interface
Relay load output:3-wire interface, all terminals have terminal blocks
1, NO:relay normally open interface, the relay is suspended before the suction, after the suction is shorted with COM
2, COM:relay common interface
3, NC:relay normally closed interface, shorted to COM before the relay is sucked, suspended after suction
Module Function
Users can choose the required functions and parameters by simple operation. All parameters can be saved after power-off. The time parameter setting can be adjusted by 0.1 second minimum, and the precision is better than 0.01 second.
For example, if the user selects the function 16, the system will save the user settings, and the function 16 will be automatically run each time the phone is turned on until the user changes the settings again.
Function 1:Power-on delay pull-in:After the delay of T1 from the start of power-on, the relay is closed, T1 is adjustable between 0.1 seconds and 270 hours, and a high-level pulse signal is given to the X1 interface at any time. Reset and resume running;
Function 2:Power-on delay off:When the power is on, the relay is closed. After the T1 time is closed, the relay is disconnected. T1 is adjustable between 0.1 seconds and 270 hours. A high-level pulse signal is given to the X1 interface at any time. , this function resets and restarts;
Function 3:Timing pull-in and then disconnect:the relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 4:Timing disconnection and re-sucking:the relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 5:Infinite loop mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the above state is repeated; T1 and T2 are between 0.1 second and 270 hours. Adjustable between each time, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 6:Infinite loop mode 2:The relay immediately picks up when power is on, the relay turns off after the pull-in time T1 arrives; the relay picks up after the break time T2 arrives, and then repeats the above state, T1 and T2 are in 0.1 second-270 Adjustable between hours, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts operation;
Function 7:Limited cycle mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the NX times are repeated, T1 and T2 are at 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 8:Limited cycle mode 2:The relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and then the NX times are repeated, T1 and T2 are in 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 9:Self-locking relay mode:A high-level pulse signal is sent to the relay X1 interface, the relay is pulled in, and a high-level pulse signal relay is turned off.
Function 10:Level trigger relay mode (including delay off function):When the power is turned on, the relay is disconnected, and a high level signal is sent to the X1 interface. The relay immediately pulls in. After the X1 port signal disappears, the relay still pulls in. After the pull-in time T1 arrives, the relay is turned off, and T1 is adjustable between 0 seconds and 270 hours.
Note:In this function, if T1 is set to 0 seconds, it will become:X1 port has a high level signal relay to pull in, and if there is no signal, it will be disconnected immediately.
Function 11:Timing pull-up after triggering:the relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface, delaying the T1 time relay to pull in, T1 is adjustable between 0.1 seconds and 270 hours, repeating to the X1 interface a high-level pulse signal, repeating the above functions more than once;
Function 12:After the trigger, the timing is disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. The relay is closed, and the T1 time relay is disconnected. The T1 is adjustable between 0.1 seconds and 270 hours. Repeat a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 13:After the trigger, the timing is closed and then disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, T1 And T2 can be adjusted between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions;
Function 14:After the trigger, the timing is disconnected and re-closed:the relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the disconnection time T2 arrives. Pull-in, T1 and T2 are adjustable between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 15:Infinite loop mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected and then repeated. The above actions, T1 and T2 are adjustable between 0.1 second and 270 hours, and a high-level pulse signal is repeatedly given to the X1 interface, and the above functions can be restarted;
Function 16:Infinite loop mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives. Then repeat the above actions, delay T1 and T2 to be adjustable between 0.1 seconds and 270 hours, repeat a high-level pulse signal to the X1 interface, and restart the above functions;
Function 17:Limited cycle timing mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, and then the relay is turned off. Repeat NX times or more, T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, and the cycle number NX is adjustable between 1-9999 times. Repeating a high-level pulse signal to the X1 interface can restart the above functions;
Function 18:Limited cycle timing mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is immediately pulled in, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the break time T2 arrives. Pull in, then repeat NX times or more, at this time T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, the number of cycles NX is adjustable between 1-9999 times, repeating a high-level pulse signal to the X1 interface. , you can restart the above functions;
Function 19:Conditional cycle mode 1:The relay is disconnected at power-on, giving a high-level signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, as long as the X1 port is high. Does not disappear, the module will repeat the above action, T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Function 20:Conditional loop mode 2:The relay is disconnected at power-on, a high level signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives, as long as X1 The high level of the port does not disappear, the module will repeat the above action, the extension T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Package Included
1 x Multifunctional Relay Module
Weight | 0.027 kg |
---|
Customers Also Viewed
50Pcs 12V Female DC Power Socket Jack Plug Wire Connector Cable CCTV DC 5.5 x 2.1mm
$32.76Module ComponentsAdd to cartFeaturesDC 5.5 x 2.1mm.Wire Specification:0.15mm²Length:Approx. 27cmMax Current Rating:2AMax Power Rating:60WTransmission voltage:1V~38VUsage temperature:-50→~65→Material:Copper WireUse for:Led Driver/ Strip connector/ CCTV Camera.Package Included50 x 12V DC Connector Cables
EMC EMI Low Noise Pre-RF Amplifier 20dB 5MHz-5GHz RFamp002
$87.30RF amplifierAdd to cartParameter1. Power supply voltage:11V-15V DC2. Gain:greater than 20DB in the 30MHz-1GHz frequency band3. Input and output impedance:50┯4. Maximum output power:10dBm5. Input signal:-10DBm6. Bandwidth:30MHz to 3GHz (gain is different under different frequencies)Measured gain (prototype)F=5.0MHZ GAIN=13.15DBF=10.0MHZ GAIN=23.89DBF=30.0MHZ GAIN=27.06DBF=50.0MHZ GAIN=27.92DBF=500.0MHZ GAIN=24.84DBF=1.0GHZ GAIN=22.01DBF=1.5GHZ GAIN=20.72DBF=2.5GHZ GAIN=17.65DBF=3.5GHZ GAIN=10.06DBF=4.0GHZ GAIN=9.09DBF=5.0GHZ GAIN=8.90DB7. Noise figure NF (theoretical value)500MHz@ 0.6dB1GHz@ 0.7dB2GHz@ 0.7dB3GHz@ 1.1dB4GHz@ 1.6dB5GHz@ 2.1dBComparison …
EMC EMI Low Noise Pre-RF Amplifier 20dB 5MHz-5GHz RFamp002Read More
RX24 100W 30R 30RJ Metal Aluminum Case High Power Resistor Golden Metal Shell Case Heatsink Resistance Resistor
$6.55Electronic Accessories & SuppliesAdd to cartFeaturesIt has the characteristics of small size, high power and high precision.It is sealed by professional technology.It has the advantages of stronger heat resistance, higher temperature resistance, moisture resistance, high anti-vibration and explosion protection.Scope of application:Testing power supply, frequency converter, automobile LED lamp, automation equipment, audio, frequency divider, servo industry and other harsh industrial control …
5pcs SRX882 433/315MHz Superheterodyne Receiver Module Board for ASK Transmitter Module
$16.71Smart ModuleAdd to cartItem OverviewThe SRX882 is a super-heterodyne receiver module with a micropower and strong driving force in conjunction with the ASK transmitter module. It has high stability, anti-interference and high cost performance, and also has a strong driving force, which can pass ROHS, FCC, CE and other certifications. The data port can be directly connected to …
5pcs SRX882 433/315MHz Superheterodyne Receiver Module Board for ASK Transmitter ModuleRead More
13.5mm Adjustable Laser Pointer Module Holder Mount Clamp 3 Axis
$42.51Engraving Parts & AccessoriesAdd to cartDescriptionMaterial:stainless steelColor:blackMount Inner Diameter:13.5mmSize:40X60mm/1.57X2.36inch(L*H)Feature1. Stainless steel laser moudle holder2. Professional angle and height adjustable design3. Installed on the laser module,it can become a professional laser pointer or laser locator4. Can also used a as a heatsink for the laser module,extend the laser module life time5. Fit for 12mm diameter laser modulePackage included1X Laser Module Holder
Mask Scary Glow Mask LED Mask for Halloween Mask Party Masks Neon Maske Skeleto Halloween Party Decor
$17.17EL ProductsAdd to cartColor. Red / Color. Orange / Color. Yellow / Color. Blue / Color. Blue / Color. Purple / Color. White / Color. Pink / Color. Fluorescent Green / Color. Green / Color. Transparent Blue /
Reviews
There are no reviews yet.