DC 24V Multifunctional Relay Module with LED Display Delay /Self Lock / Cycle / Timing
$13.88
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Features
1. New upgraded version with up to 20 functions preset to meet more application needs;
2. Optimize the software and hardware design, enhance the anti-interference ability of the module, and the system is more stable and reliable;
3. With power supply anti-reverse function, it will not damage the module due to wrong power supply;
4. The timing can be adjusted between 0.1 seconds and 270 hours;
5. All setting parameters can be saved, and the setting contents will not be lost when power is off.
Electrical Parameter
Working voltage:DC 24V
Working current:05V module is less than 90mA (less than 15mA when the relay is not operating, the display is less than 3mA)
Working temperature:-30 ° C – 70 ° C (limit range -40 ° C – 80 ° C)
Relay normally open port maximum load capacity:DC 0-30V/10A, AC 0-250V/10A
Relay normally closed port maximum load capacity:DC 0-28V/10A, AC 0-125V/10A
Dimensions:66mm x 41mm x 20mm (length x width x height)
Module Interface
Module voltage / signal input:3-wire interface, all interfaces have terminal blocks for user convenience
1, DC+:DC power supply positive
2, DC-:DC power supply negative
3, X1:input signal detection interface
Relay load output:3-wire interface, all terminals have terminal blocks
1, NO:relay normally open interface, the relay is suspended before the suction, after the suction is shorted with COM
2, COM:relay common interface
3, NC:relay normally closed interface, shorted to COM before the relay is sucked, suspended after suction
Module Function
Users can choose the required functions and parameters by simple operation. All parameters can be saved after power-off. The time parameter setting can be adjusted by 0.1 second minimum, and the precision is better than 0.01 second.
For example, if the user selects the function 16, the system will save the user settings, and the function 16 will be automatically run each time the phone is turned on until the user changes the settings again.
Function 1:Power-on delay pull-in:After the delay of T1 from the start of power-on, the relay is closed, T1 is adjustable between 0.1 seconds and 270 hours, and a high-level pulse signal is given to the X1 interface at any time. Reset and resume running;
Function 2:Power-on delay off:When the power is on, the relay is closed. After the T1 time is closed, the relay is disconnected. T1 is adjustable between 0.1 seconds and 270 hours. A high-level pulse signal is given to the X1 interface at any time. , this function resets and restarts;
Function 3:Timing pull-in and then disconnect:the relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 4:Timing disconnection and re-sucking:the relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and T1 and T2 are adjustable between 0.1 seconds and 270 hours. , a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 5:Infinite loop mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the above state is repeated; T1 and T2 are between 0.1 second and 270 hours. Adjustable between each time, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts the operation;
Function 6:Infinite loop mode 2:The relay immediately picks up when power is on, the relay turns off after the pull-in time T1 arrives; the relay picks up after the break time T2 arrives, and then repeats the above state, T1 and T2 are in 0.1 second-270 Adjustable between hours, give a high-level pulse signal to the X1 interface at any time, this function resets and restarts operation;
Function 7:Limited cycle mode 1:The relay is disconnected at power-on, the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then the NX times are repeated, T1 and T2 are at 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 8:Limited cycle mode 2:The relay is closed when power is on, the relay is disconnected after the pull-in time T1 arrives; the relay is closed after the disconnection time T2 arrives, and then the NX times are repeated, T1 and T2 are in 0.1 second – Adjustable between 9999 seconds, the number of cycles NX can be adjusted between 1-9999 times, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarted.
Function 9:Self-locking relay mode:A high-level pulse signal is sent to the relay X1 interface, the relay is pulled in, and a high-level pulse signal relay is turned off.
Function 10:Level trigger relay mode (including delay off function):When the power is turned on, the relay is disconnected, and a high level signal is sent to the X1 interface. The relay immediately pulls in. After the X1 port signal disappears, the relay still pulls in. After the pull-in time T1 arrives, the relay is turned off, and T1 is adjustable between 0 seconds and 270 hours.
Note:In this function, if T1 is set to 0 seconds, it will become:X1 port has a high level signal relay to pull in, and if there is no signal, it will be disconnected immediately.
Function 11:Timing pull-up after triggering:the relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface, delaying the T1 time relay to pull in, T1 is adjustable between 0.1 seconds and 270 hours, repeating to the X1 interface a high-level pulse signal, repeating the above functions more than once;
Function 12:After the trigger, the timing is disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. The relay is closed, and the T1 time relay is disconnected. The T1 is adjustable between 0.1 seconds and 270 hours. Repeat a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 13:After the trigger, the timing is closed and then disconnected:the relay is turned off when the power is turned on, and a high-level pulse signal is sent to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, T1 And T2 can be adjusted between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions;
Function 14:After the trigger, the timing is disconnected and re-closed:the relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the disconnection time T2 arrives. Pull-in, T1 and T2 are adjustable between 0.1 seconds and 270 hours, repeating a high-level pulse signal to the X1 interface, repeating the above functions more than once;
Function 15:Infinite loop mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected and then repeated. The above actions, T1 and T2 are adjustable between 0.1 second and 270 hours, and a high-level pulse signal is repeatedly given to the X1 interface, and the above functions can be restarted;
Function 16:Infinite loop mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives. Then repeat the above actions, delay T1 and T2 to be adjustable between 0.1 seconds and 270 hours, repeat a high-level pulse signal to the X1 interface, and restart the above functions;
Function 17:Limited cycle timing mode after triggering 1:The relay is disconnected at power-on, giving a high-level pulse signal to the X1 interface. After the disconnection time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, and then the relay is turned off. Repeat NX times or more, T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, and the cycle number NX is adjustable between 1-9999 times. Repeating a high-level pulse signal to the X1 interface can restart the above functions;
Function 18:Limited cycle timing mode after triggering 2:The relay is disconnected at power-on, a high-level pulse signal is sent to the X1 interface, the relay is immediately pulled in, the relay is turned off after the pull-in time T1 arrives, and the relay is turned off after the break time T2 arrives. Pull in, then repeat NX times or more, at this time T1 and T2 are adjustable between 0.1 seconds and 9999 seconds, the number of cycles NX is adjustable between 1-9999 times, repeating a high-level pulse signal to the X1 interface. , you can restart the above functions;
Function 19:Conditional cycle mode 1:The relay is disconnected at power-on, giving a high-level signal to the X1 interface. After the delay time T1 arrives, the relay is closed; after the pull-in time T2 arrives, the relay is disconnected, as long as the X1 port is high. Does not disappear, the module will repeat the above action, T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Function 20:Conditional loop mode 2:The relay is disconnected at power-on, a high level signal is sent to the X1 interface, the relay is closed, the relay is turned off after the pull-in time T1 arrives, and the relay is closed after the disconnection time T2 arrives, as long as X1 The high level of the port does not disappear, the module will repeat the above action, the extension T1 and T2 can be adjusted between 0.1 seconds and 270 hours. If the high level signal of the X1 interface disappears, the relay will be disconnected immediately and the function will be reset.
Package Included
1 x Multifunctional Relay Module
Weight | 0.027 kg |
---|
Customers Also Viewed
150W 18V Mono Solar Panel Dual USB 12V/5V DC Monocrystalline Solar Charger for Car RV Boat Battery Charger Waterproof
$164.01Solar PanelAdd to cart150W 18V Mono Solar Panel Dual USB 12V/5V DC Monocrystalline Flexible Solar Charger For Car RV Boat Battery ChargerFeatures1.Equipped with 12V DC5.5×2.1 & 5V USB output interface.2.Dedicated for 12V battery and 5V device charging.3.EVA+PET at front panel, flexible, light-weight but durable.4.Mono-crystalline solar Cell with efficient up to 21%.5.4x eyelet and free 2x carabiners for mounting …
DIY 5×7 Prototype Paper PCB Universal Experiment Matrix Circuit Board
$4.36Module ComponentsAdd to cartDescriptionMaterial:Single Side Copper PCB.Hole Dia:about 1mm.Hole pitch:standard 2.54mm.For point to point DIY soldering.Size:5cm x 7cm – 1.97inch x 2.76inch.Quantity:1PCPackage Included1 x PCB Board
FR4 300x200mm Double Side Copper Clad Laminate PCB Board Fiberboard CCL
$17.48Other Module BoardAdd to cartFR4 300x200mm Double Side Copper Clad Laminate PCB Board Fiberboard CCLSpecificationPanel Size:Approx. 300mm x 200mm or 11.8inch x 7.88inch (inch)Thickness:0.06inch ±0.005 (1.5mm ± 0.15)Weight:Approx. 194g eachLayers:Double SidePanel:FR4Operating temperature:Up to 140 °C or 285°FDescriptionThis Double PCB Copper Clad Laminate Board is made of copper foil by the hot-pressing technology.Super-fine steel-wool, Restore4, Tarn-X, roscherite, Zap or similar …
FR4 300x200mm Double Side Copper Clad Laminate PCB Board Fiberboard CCLRead More
10pcs DC Jack Power 7~12V to DC5V/3.3V Step Down Converter Voltage Regulator Power Supply Module for Breadboad OPEN-SMART for Arduino – products that work with official for Arduino boards
$34.43Power Supply ModuleAdd to cartSize ConversionInchesCentimetersPlease according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.DescriptionThis is a mini LDO step-down power module based on AMS1117-5.0 and AMS1117-3.3, and it output fixed 5V / 3.3V.It is a small size, lightweight, especially for model airplanes, smart cars, DIY …
60A DC Brush Motor Speed Controller forward Reverse PWM Control Pulse Width Speed Digital Display 10-55V/3KW
$69.50Motor PWM Speed ControllerAdd to cartThe main purpose1. All kinds of general-purpose DC brush motor speed control2. Various types of automotive motor speed control (automobile cooling fan speed control, car fan speed control, car wiper motor speed control, car air conditioning fan speed control)3. Production line conveyor speed control, pipeline exhaust fan speed regulation, treadmill speed regulation, multiple computer fan …
24Value 500Pcs 0.1uF-1000uF Electrolytic Capacitors + 10Value 600 Pcs 0.1uF-10uF Ceramic Capacitor Assortment Box Kit
$32.79Module ComponentsAdd to cartProduct FeaturesThe nice sturdy box helps you keep all caps in order.Assortment Box for easy access.All of the capacitor is marked the value,easy to find what you need.High quality and long life. Package Included1 x 10Value 600pcs Ceramic Capacitor1 x 24Value 500pcs Electrolytic Capacitor
5Pcs KY-015 DHT11 Temperature Humidity Sensor Module
$17.16Sensor & Detector ModuleAdd to cart5Pcs KY-015 DHT11 Temperature Humidity Sensor Module ForDescriptionThe sensor module is including resistive humidity sensing component and NTC temperature testingThe compatible digital temperature humidity sensor module is component and connected with 8-byte MCUGreat anti-interference ability and durableWith fixed bolt hole for easy installation3 DO small plate switch digital output interface connected microcontroller IO portTwo module …
5Pcs KY-015 DHT11 Temperature Humidity Sensor ModuleRead More
100pcs 270uF 16V 8x8mm Low ESR 16V270uF for Motherboard VGA Solid Capacitor
$29.08Electronic Accessories & SuppliesAdd to cartDescriptionLow ESR, high ripple current capabilityESR 5mΩ max (2 to 4VDC)Longer life(20000 hours at 106 Celsius)Rated voltage:2 to 16VDCCategory temperature:-55 to +105 CelsiusTolerance:+/-20%(M)Package included100 x Solid Capacitors
Reviews
There are no reviews yet.